Plan Review Details - Permit 13030089
Plan Review Stops For Permit 13030089
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-04-08 Cont ID  
Sent By jwitmer Date 2013-04-08 Time 16:35 Rev Time 0.00
Received By jwitmer Date 2013-04-08 Time 16:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-03-13 Cont ID  
Sent By jwitmer Date 2013-03-13 Time 11:28 Rev Time 0.00
Received By jwitmer Date 2013-03-13 Time 11:28 Sent To  
Notes
2013-03-13 11:40:32BUILDING PLAN REVIEW
 PERMIT: 13030089
 ADD: 1610 PALM BEACH LAKES
 CONT: DOSDOURIAN ENTERPRISES
 TEL: (561)844-2990
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 03/13/2013
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION AND PLANS INDICATE THE
 INSTALATION OF A NEW ADA LIFT BUT NO MANUFACTURERS
 INFORMATION SHEETS INDICATING THAT THIS LIFT COMPLIES
 WITH ASME A18.1 1999 OE 2003 EDITION. 2010 FL
 ACCESSIBILITY CODE 410.1.
  
 2) 410.4 PLATFORM TO RUNWAY CLEARANCE.
 THE CLEARANCE BETWEEN THE PLATFORM SILL AND THE EDGE OF
 ANY RUNWAY LANDING SHALL BE 1 INCH (32 MM) MAXIMUM.
  
 3) 410.5 OPERABLE PARTS.
 CONTROLS FOR PLATFORM LIFTS SHALL COMPLY WITH 309.
  
 4) 410.6 DOORS AND GATES.
 PLATFORM LIFTS SHALL HAVE LOW-ENERGY POWER-OPERATED
 DOORS OR GATES COMPLYING WITH 404.3. DOORS SHALL REMAIN
 OPEN FOR 20 SECONDS MINIMUM. END DOORS AND GATES SHALL
 PROVIDE A CLEAR WIDTH 32 INCHES (815 MM) MINIMUM. SIDE
 DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 42 INCHES
 (1065 MM) MINIMUM.
  
 EXCEPTION: PLATFORM LIFTS SERVING TWO LANDINGS MAXIMUM
 AND HAVING DOORS OR GATES ON OPPOSITE SIDES SHALL BE
 PERMITTED TO HAVE SELF-CLOSING MANUAL DOORS OR GATES.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-03-15 Cont ID  
Sent By rlecky Date 2013-03-15 Time 11:22 Rev Time 0.00
Received By rlecky Date 2013-03-15 Time 11:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-04-08 Cont ID  
Sent By jwitmer Date 2013-04-08 Time 16:35 Rev Time 0.00
Received By jwitmer Date 2013-04-03 Time 18:56 Sent To  
Notes
2013-04-03 18:56:36TO JW DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-03-15 Cont ID  
Sent By rlecky Date 2013-03-15 Time 11:22 Rev Time 0.00
Received By rlecky Date 2013-03-04 Time 10:04 Sent To  
Notes
2013-03-05 10:12:11B15