Plan Review Details - Permit 13030034
| Plan Review Stops For Permit 13030034 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-17 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2013-04-17 17:12:24 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LISTS: | | | | | | 1. FOR THE WINDOWS : REVISE THE PLAN TO SHOW ROOM | | | DESIGNATIONS. NOTE EXISTING CONDITIONS (TYPE OF WINDOW) | | | AND OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. | | | THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | FIRST PLAN SHOWED 60" WINDOW AT BEDROOM, SECOND SHOWS A | | | 48". IF THIS WINDOW IS 48" HIGH, REVISE PLAN TO INCLUDE | | | TYPE OF WINDOW THAT IS EXISTING. | | | | | | 3RD REVIEW, A PLAN SUBMITTED WITH NO WINDOWS SHOWN, AND | | | DOES NOT CORRELATE WITH ELEVATIONS AS THERE IS NO | | | COMPASS NORTH ON THE PLAN. TYPE OF EXISTING WINDOWS NOT | | | PROVIDED. | | | | | | 2. FOR THE SHUTTERS: | | | | | | THE INSTALLATION SCHEDULE SUBMITTED DOES NOT INCLUDE | | | THE INFORMATION "SHUTTER MOUNTING CONNECTIN TYPE", SEE | | | SHEETS 12 THROUGH 15 OF THE NOA. FOR INSTANCE, | | | "ALTERNATIVE 1" WOULD REQUIRED 6" OC ANCHOR SPACING, | | | SEE DETAIL. MOST OF THE CONNECTION TYPES APPEAR TO | | | REQUIRE 6" SPACING, BUT 8" IS PROPOSED. HOWEVER WITHOUT | | | KNOWING WHICH INSTALLATION METHOD (CONNECTION TYPE) IS | | | PROPOSED, COMPLIANCE CANNOT BE DETERMINED. | | | | | | PRESSURES ARE TOO HIGH FOR THE SHUTTERS WHICH ARE | | | LIMITED TO -72PSF. IT IS NOT CLEAR WHY YOU HAVE | | | SPECIFIED THESE PRESSURES: +-45 WOULD MEET MINIMUM CODE | | | COMPLIANCE FOR ALL OPENINGS. FBC R 301 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-03-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-13 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-13 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2013-03-13 15:20:29 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. FOR THE WINDOWS : REVISE THE PLAN TO SHOW ROOM | | | DESIGNATIONS. NOTE EXISTING CONDITIONS (TYPE OF WINDOW) | | | AND OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. | | | THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | FIRST PLAN SHOWED 60" WINDOW AT BEDROOM, SECOND SHOWS A | | | 48". IF THIS WINDOW IS 48" HIGH, REVISE PLAN TO INCLUDE | | | TYPE OF WINDOW THAT IS EXISTING. | | | | | | 2. FOR THE SHUTTERS: | | | | | | COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2ND REVIEW, NOT ADDRESSED. A BLANK INSTALLATION | | | SCHEDULE WAS SUBMITTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-04 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-04 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2013-03-04 08:46:24 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FOR THE WINDOWS : REVISE THE PLAN TO SHOW ROOM | | | DESIGNATIONS. NOTE EXISTING CONDITIONS (TYPE OF WINDOW) | | | AND OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. | | | THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2. FOR THE SHUTTERS: | | | | | | COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-03-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-03-01 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-03-01 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2013-03-01 14:45:05 | APPROVED FOR 6/6 SH, CLEAR GLASS WHITE FRAMES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-11 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2013-04-12 13:15:23 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-13 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-11 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2013-03-12 08:58:49 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-04 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-04 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
|