Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-03-21 Cont ID  
Sent By jgomez Date 2013-03-21 Time 10:51 Rev Time 0.00
Received By jgomez Date 2013-03-21 Time 10:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-03-04 Cont ID  
Sent By jgomez Date 2013-03-01 Time 16:59 Rev Time 0.00
Received By jgomez Date 2013-03-01 Time 16:42 Sent To  
Notes
2013-03-01 17:00:09RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION
 IS TOO LOW. SEC. 109.3 CITY AMENDMENTS TO FBC. PERMIT
 APPLICATION STATES 2000 S.F. OR ROOF AREA. THIS HOUSE
 ROOFING SQUARE FOOTAGE IS A LOT MORE THAN 2,000 S.F.
 REVISE THE TOTAL ROOF SQUARE FEET AND VALUATION.
  
 2- SEC. 105.15 OF CITY AMENDMENTS TO FBC. FLORIDA
 STATUTE SEC. 553.844. (3)(C) REQUIRES THAT ANY PERMIT
 WHICH THE COST IS MORE THAN $50,000 NEED TO PROVIDE
 PROVISION OF OPENINGS PROTECTION. ALL THE GLAZING ON
 DOORS AND WINDOWS NEED TO HAVE HURRICANE IMPACT
 PROTECTION. PROVIDE INFORMATION SOWING EXISTING
 OPENINGS IMPACT PROTECTION. SEE BELOW FOR COPY OF
 FLORIDA STATUTE SECTION:
  
 (C) ANY ACTIVITY REQUIRING A BUILDING PERMIT THAT IS
 APPLIED FOR ON OR AFTER JULY 1, 2008, AND FOR WHICH THE
 ESTIMATED COST IS $50,000 OR MORE, MUST INCLUDE
 PROVISION OF OPENING PROTECTIONS AS REQUIRED WITHIN THE
 FLORIDA BUILDING CODE FOR NEW CONSTRUCTION FOR A
 BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS
 REGION AS DEFINED IN S. 1609.2 OF THE INTERNATIONAL
 BUILDING CODE (2006) AND THAT HAS AN INSURED VALUE OF
 $750,000 OR MORE, OR, IF THE BUILDING IS UNINSURED OR
 FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT
 PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR
 PURPOSES OF AD VALOREM TAXATION OF $750,000 OR MORE.
  
 3- WHEN THE VALUE OF THE STRUCTURE IS MORE THAN
 $300,000, THEN ROOF TO WALL CONNECTIONS ARE REQUIRED BY
 SEC. 611.8 OF 2010 FBC-EXISTING BUILDING.
  
 4- SPECIFY ON CONCRETE TILE PRODUCT APPROVAL SUBMITTED
 WHICH SPECIFIC CONCRETE TILE AND APPLICATION
 (INTER-DEPENDENT OR INDEPENDENT) IS GOING TO BE
 INSTALLED. AND, PROVIDE THE MOMENT OF RESISTANCE
 CALCULATIONS (RAS 127) TO VERIFY COMPLIANCE WITH THE
 WIND RESISTANCE RATING AS REQUIRED BY SEC. 107.2.1.2
 CITY AMENDMENTS TO FBC.
  
 5- SPECIFY ON ROOF UNDERLAYMENT PRODUCT APPROVAL
 SUBMITTED WHICH SPECIFIC UNDERLAYMENT IS GOING TO BE
 INSTALLED TO VERIFY COMPLIANCE WITH THE WIND RESISTANCE
 RATING AS REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS TO
 FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-03-21 Cont ID  
Sent By jgomez Date 2013-03-21 Time 10:51 Rev Time 0.00
Received By jgomez Date 2013-03-21 Time 10:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-03-01 Cont ID  
Sent By jgomez Date 2013-03-01 Time 16:43 Rev Time 0.00
Received By jgomez Date 2013-03-01 Time 16:43 Sent To  
Notes
***NONE***