| Plan Review Stops For Permit 13020651 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-02 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-02 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2013-04-03 08:25:26 | MU-2013-6297 | | | NO FEES DUE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-02-27 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-02-27 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2013-02-27 12:07:51 | BUILDING PLAN REVIEW | | | PERMIT: 133020651 | | | ADD: 400 CLEMATIS ST # 103 | | | CONT: ADVANCED AIR & PLUMBING | | | TEL: (561)662-8144 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: 02/27/2013 | | | ACTION: DENIED | | | | | | 1) SHEET D-1 PROJECT DATA INDICATE THIS IS A CHANGE OF | | | OCCUPANCY, OCCUPANCY TYPE "M" OCCUPANT LOAD 41. WHERE | | | AS SHEET A-1 UNDER THE HEADING PLAN NOTE # 9 THE | | | OCCUPANT LOAD IS INDICATED AS 115. IT APPEARS THERE IS | | | A DISCREPANCY. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 2) SHEET A1 THE NEW RESTROOM DOOR FOR A FRONTAL | | | APPROACH DOES NOT HAVE THE REQUIRED60 INCHES MINIMUM | | | BEFORE YOU HIT A WALL. 2010 FL ACCESSIBILITY CODE | | | FIGURE 404.2.4.1(A). | | | | | | 3) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-04-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-04-01 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-04-01 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-03-05 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-05 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-04 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2013-04-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-15 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2013-04-15 14:56:21 | 400 CLEMATIS STREET - SUITE "D" | | | PERMIT #13020651 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO***** | | | | | | PROVIDE KITCHEN WING WALL PER EMAIL SKETCH DATED | | | 04/15/13 FROM ARCHITECT J. BRASSEUR. | | | | | | (REVIEW COMMENT: THE EXIT ACCESS PATH FROM TOILET ROOM | | | #2 TO THE FRONT EXIT DOOR REQUIRES TRAVEL THROUGH THE | | | KITCHEN SPACE WHICH IS PROHIBITED BY NFPA 101 (2009 ED. | | | WITH FLORIDA AMENDMENTS) SECTION 7.5.2.1.) | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-04-01 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-01 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-01 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2013-04-01 14:03:09 | 400 CLEMATIS STREET - SUITE "D" | | | PERMIT #13020651 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE EXIT ACCESS PATH FROM TOILET ROOM #2 TO THE FRONT | | | EXIT DOOR REQUIRES TRAVEL THROUGH THE KITCHEN SPACE | | | WHICH IS PROHIBITED BY NFPA 101 (2009 ED. WITH FLORIDA | | | AMENDMENTS) SECTION 7.5.2.1. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-03-01 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2013-03-01 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2013-03-01 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2013-03-01 11:02:36 | FIRE DEPARTMENT REVIEW | | | PERMIT: # 13020651 | | | ADDRESS: 400 CLEMATIS STREET | | | CONTRACTOR: ADVANCED AIR & PLUMBER | | | PHONE:561 662-8144 | | | ACTION: DENIED | | | | | | FLORIDA FIRE PREVENTION CODE 2010 EDITION | | | | | | 1. DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE | | | FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA | | | EDITION OF NFPA 1 AND NFPA 101. | | | | | | 2. ALL DEMOLITION WORK SHALL CONFORM TO THE | | | REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS | | | SHALL BE REMOVED FROM THE SITE DAILY. | | | | | | 3. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | DERRICK L. DANIELS, BATTALION CHIEF / FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 804-4909 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-12 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-02 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2013-04-03 08:21:26 | INCOMING SENT TO B-13 BOX, PLANS SUBMITTED FROM COUNTY | | | IMPACT FEE REVIEW.. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-04-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-15 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-03-29 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2013-03-29 16:55:12 | EXPEDITED | | | 2ND RUN | | | B--13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-14 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-02-22 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2013-02-22 12:48:07 | EXPEDITED | | | B--5 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2013-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-02 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-02 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-04-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-02 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-02 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2013-04-02 11:38:09 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-02-27 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-02-27 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2013-02-27 12:08:18 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-03-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-11 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-03-11 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2013-03-11 10:23:00 | ****PROVISO**** | | | | | | SEPARATE PERMIT AND PLANS REQUIRED FOR COOLERS AND HOOD | | | | | | SUBMIT LOUVER PRODUCT APPROVAL AS A REVISION | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-04-02 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-04-02 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-04-02 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-02-28 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-02-28 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-02-27 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2013-02-28 10:00:31 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. AS THIS IS A FOOD SERVICE ESTABLISHMENT, SEPARATE | | | FACILITIES ARE REQUIRED FOR EACH SEX. | | | 403.2 SEPARATE FACILITIES. | | | WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE | | | FACILITIES SHALL BE PROVIDED FOR EACH SEX. | | | EXCEPTIONS: 2. SEPARATE FACILITIES SHALL NOT BE | | | REQUIRED FOR FOOD SERVICE ESTABLISHMENTS WHICH SEAT 10 | | | PERSONS OR LESS. | | | | | | 2. IF THE EXISTING RESTROOM IS TO BE USED AS THE | | | SEPARATE FACILITY, THEN IT CAN NOT HAVE A ROUTE THROUGH | | | THE KITCHEN. | | | 403.3 REQUIRED PUBLIC TOILET FACILITIES. | | | CUSTOMERS, PATRONS AND VISITORS SHALL BE PROVIDED WITH | | | PUBLIC TOILET FACILITIES IN STRUCTURES AND TENANT | | | SPACES INTENDED FOR PUBLIC UTILIZATION. THE NUMBER OF | | | PLUMBING FIXTURES LOCATED WITHIN THE REQUIRED TOILET | | | FACILITIES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION | | | 403 FOR ALL USERS. EMPLOYEES SHALL BE PROVIDED WITH | | | TOILET FACILITIES IN ALL OCCUPANCIES. EMPLOYEE TOILET | | | FACILITIES SHALL BE EITHER SEPARATE OR COMBINED | | | EMPLOYEE AND PUBLIC TOILET FACILITIES. | | | 403.3.1 ACCESS. | | | THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY | | | SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE | | | ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES | | | SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR | | | OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE | | | ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING | | | CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO | | | THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE | | | BUILDING IS OCCUPIED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-04-10 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-04-10 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-04-02 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2013-04-10 16:26:13 | GARBAGE DISPOSAL TO BE ACCOMODATED THROUGH CITY OWNED | | | ALLEY COMPACTOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-03-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-03-14 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-03-14 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2013-03-14 13:12:22 | PLEASE PROVIDE INFORMATION REGARDING THE LOCATION OF | | | THE DUMPSTER OR HOW THE GARBAGE WILL BE DISPOSED. | | | PREVIOUS USE WAS NOT A RESTAURANT. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|