| Plan Review Stops For Permit 13020613 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-06-13 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-06-12 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-20 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-20 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2013-05-20 07:39:28 | BUILDING PLAN REVIEW | | | PERMIT: 13020613 | | | ADD: 6300 S DIXIE HWY | | | CONT: ATLANTIDA | | | TEL: (561)313-8126 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: 04/20/2013 | | | ACTION: DENIED | | | | | | ***** NOTE*****FLORIDA STATUTE 553.80(2)(B) | | | DESIGN PROFESSIONAL DOCUMENTS. | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY,LIGHTING, VENTILATION, MECHANICAL, | | | PLUMBING, AND GAS SYSTEMS, OR OTHER REQUIREMENTS | | | IDENTIFIED BY RULE OF THE FLORIDA BUILDING COMMISSION | | | ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL GOVERNMENT | | | SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH REVIEW THE | | | PLANS ARE REJECTED FOR THAT CODE VIOLATION A FEE OF | | | FOUR TIMES THE AMOUNT OF THE PORTION OF THE PERMIT FEE | | | ATTRIBUTED TO PLAN REVIEW. | | | | | | 1-2) COMPLIED. | | | | | | | | | 3) 3RD REQUEST, SEMI-COMPLIED. SHEET A-1 NOTE # 4 | | | INDICATES A BUSINESS OCCUPANCY AND THE REFERENECE TO | | | CODE SECTION 306 WHICH IS FACTORY? THEN UNDER THE | | | HEADING NOTES OCCUPANCY TYPE ; ASSEMBLY, THIS IS A YOGA | | | STUDIO, THIS TRUELY APPEARS TO BE A EXERCISE ROOM | | | WITHOUT EQUIPMENT AND THE 15 SQ FT PER PERSON SHOULD BE | | | USED PROVIDE WHAT AREA WILL BE USED FOR YOGA PROVIDE | | | THE SQ FT PER AREA AND OCCUPANT LOADS FOR EACH AREA. | | | THE YOGA AREA AREA IS 490 SQ FT / 15 SQ FT PER OCCUPANT | | | = 33 OCCUPANTS. . PLEASE PROVIDE WHAT METHOD YOU USED | | | TO PROVIDE AN OCCUPANT LOAD OF 15. 2010 FBC-B TABLE | | | 1004.1.1. THE BUILDING OFFICIAL AND FIRE MARSHALL BOTH | | | AGREE THAT YOGA MATS DO NOT CONSTITUTE GYM EQUIPMENT | | | AND THE 50 SQ FT CAN NOT BE TAKEN FOR ALLOWABLE SQUARE | | | FEET PER OCCUPANT FOR GYM EQUIPMENT. | | | | | | 4)3RD REQUEST. SHEET 1-A UNDER NOTES CLASSIFIES THIS | | | BUILDING AS A TYPE 5 BUILDING. UNDER THE 2010 FBC-B | | | TABLE 503.1 & TABLE 601 THE TABLES LIST 5A OR 5B. | | | | | | 5-7) COMPLIED. | | | NEW COMMENTS: | | | | | | 8)COMPLIED. | | | | | | 9) 2ND REQUEST. THE PLANS ALSO SHOW FOR THE SECOND TIME | | | A EXIT FROM THE SECOND STORY BUT THE DETAIL A -A-1 | | | INDICATES A ROOF ABOVE, PLEASE CLARIFY WHAT TYPE | | | CONDITION IS LOCATED ABOVE THIS UNIT? IS THERE ANOTHER | | | OCCUPANCY TYPE ABOVE AND HOW ARE YOU OBTAINING | | | OCCUPANCY SEPERATION FROM THE UNIT ABOVE? 2010 FBC-B | | | TABLE 508.4. | | | | | | 10) 2ND REQUEST. SHEET A1 WITH THE STAIRWELL FROM THE | | | SECOND FLOOR, IT APPEARS THAT YOU CAN ENTER THE TENANT | | | SPACE THROUGH A BUILDING UTILITY CLOSET, WHERE IS THE | | | TENANT SEPERATION LINE, AND WHY CAN YOU ENTER THE | | | UTILITY CLOSET FROM THE VERTICAL EXIT. THE 2010 FBC-B | | | 1022.4 OPENINGS THROUGH AN EXIT ENCLOSURE ARE | | | PROHIBITED EXCEPT FOR REQUIRED EXIT DOORS.1022.3 | | | OPENINGS IN EXIT ENCLOSURES OTHER THAN UNPROTECTED | | | EXTERIOR OPENINGS SHALL BE LIMITED TO THOSE NECESSARY | | | FOR EXIT ACCESS TO THE ENCLOSURE FROM NORMALLY OCCUPIED | | | SPACES AND FOR EGRESS FROM THE ENCLOSURE. | | | | | | 11)2ND REQUEST. BOTH THE NEW A1 SHEET AS WELL AS THE LS | | | SHEET INDICATE A WATER HEATER IN THE VERTICAL EXIT | | | ENCLOSURE. 2010 FBC-B 1022.4 PENETRATIONS. | | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | | VENTILATION OR PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | | SECTION 713. THERE SHALL BE NO PENETRATIONS OR | | | COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, | | | BETWEEN ADJACENT EXIT ENCLOSURES. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-04 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-04 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2013-04-04 08:35:31 | BUILDING PLAN REVIEW | | | PERMIT: 13020613 | | | ADD: 6300 S DIXIE HWY | | | CONT: ATLANTIDA | | | TEL: (561)313-8126 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: 04/04/2013 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | | | | 3) 2ND REQUEST, SEMI-COMPLIED. SHEET A-1 NOTE # 4 | | | INDICATES A BUSINESS OCCUPANCY AND THE REFERENECE TO | | | CODE SECTION 306 WHICH IS FACTORY? THEN UNDER THE | | | HEADING NOTES OCCUPANCY TYPE ; ASSEMBLY, THIS IS A YOGA | | | STUDIO, THIS TRUELY APPEARS TO BE A EXERCISE ROOM | | | WITHOUT EQUIPMENT AND THE 15 SQ FT PER PERSON SHOULD BE | | | USED PROVIDE WHAT AREA WILL BE USED FOR YOGA PROVIDE | | | THE SQ FT PER AREA AND OCCUPANT LOADS FOR EACH AREA. | | | THE YOGA AREA AREA IS 490 SQ FT / 15 SQ FT PER OCCUPANT | | | = 33 OCCUPANTS. IF YOU LOOK AT THE SAME AREA 490 SQ FT | | | WITH THE MATS BEING EQUIPMENT, 490/15= 10 OCCUPANTS. | | | PLEASE PROVIDE WHAT METHOD YOU USED TO PROVIDE AN | | | OCCUPANT LOAD OF 15. 2010 FBC-B TABLE 1004.1.1. | | | | | | 4)2ND SHEET 1-A UNDER NOTES CLASSIFIES THIS BUILDING AS | | | A TYPE 5 BUILDING. UNDER THE 2010 FBC-B TABLE 503.1 & | | | TABLE 601 THE TABLES LIST 5A OR 5B. | | | | | | 5-7) COMPLIED. | | | NEW COMMENTS: | | | | | | 8) THE NEW SET OF PLANS HAVE ELIMINATED THE FRONT | | | DOORS, ON THE A-1 SHEET BUT STILL SHOW THEM ON THE LIFE | | | SAFETY PLAN, IS THIS AN OVER SITE, ARE THE DOORS TILL | | | THERE? EXIT DISCHARGE 1027. | | | | | | 9) THE PLANS ALSO SHOW FOR THE FIRST TIME A EXIT FROM | | | THE SECOND STORY BUT THE DETAIL A A-1 INDICATES A ROOF | | | ABOVE, PLEASE CLARIFY WHAT TYPE CONDITION IS LOCATED | | | ABOVE THIS UNIT? IS THERE ANOTHER OCCUPANCY TYPE ABOVE | | | AND HOW ARE YOU OBTAINING OCCUPANCY SEPERATION FROM THE | | | UNIT ABOVE? 2010 FBC-B TABLE 508.4. | | | | | | 10) SHEET A1 WITH THE STAIRWELL FROM THE SECOND FLOOR, | | | IT APPEARS THAT YOU CAN ENTER THE TENANT SPACE THROUGH | | | A BUILDING UTILITY CLOSET, WHERE IS THE TENANT | | | SEPERATION LINE, AND WHY CAN YOU ENTER THE UTILITY | | | CLOSET FROM THE VERTICAL EXIT. THE 2010 FBC-B 1022.4 | | | OPENINGS THROUGH AN EXIT ENCLOSURE ARE PROHIBITED | | | EXCEPT FOR REQUIRED EXIT DOORS.1022.3 OPENINGS IN EXIT | | | ENCLOSURES OTHER THAN UNPROTECTED EXTERIOR OPENINGS | | | SHALL BE LIMITED TO THOSE NECESSARY FOR EXIT ACCESS TO | | | THE ENCLOSURE FROM NORMALLY OCCUPIED SPACES AND FOR | | | EGRESS FROM THE ENCLOSURE. | | | | | | 11) BOTH THE NEW A1 SHEET AS WELL AS THE LS SHEET | | | INDICATE A WATER HEATER IN THE VERTICAL EXIT ENCLOSURE. | | | 2010 FBC-B 1022.4 PENETRATIONS. | | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | | VENTILATION OR PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | | SECTION 713. THERE SHALL BE NO PENETRATIONS OR | | | COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, | | | BETWEEN ADJACENT EXIT ENCLOSURES. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-01 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-02-28 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2013-03-01 09:41:48 | BUILDING PLAN REVIEW | | | PERMIT: 13020613 | | | ADD: 6300 S DIXIE HWY | | | CONT: ATLANTIDA | | | TEL: (561)313-8126 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: 03/01/2013 | | | ACTION: DENIED | | | | | | 1) SHEET A1 NOTE # 2, UNDER THE HEADING INDICATES THE | | | USE OF TABLE 302.1.1AND 2 HOUR FIRE WALL RATINGS, IN | | | THE 2010 FBC-B THERE IS NO SUCH TABLE PLEASE UPDATE | | | PLANS TO THE 2010 FBC-B. FIRE WALLS IS THE WRONG | | | TERM,THEY ARE WALLS THAT SPLIT BUILDINGS INTO 2 | | | BUILDINGS BECAUSE OF BEING TO LARGE FOR THE BUILDING | | | TYPE DECLARED SEE 706. THE WALLS ARE TENAN SEPERATION | | | WALLS ( FIRE PARTITIONS 709) OR OCCUPANCY SEPERATION | | | WALLS. | | | | | | 2) SHEET A-1 NOTE # 3 UNDER THE HEADING INDICATES THE | | | USE OF TABLE 302.1.1 AND 1 HOUR FIRE WALLS, IN THE 2010 | | | FBC-B THERE IS NO SUCH TABLE PLEASE UPDATE PLANS TO THE | | | 2010 FBC-B. | | | | | | 3) SHEET A-1 NOTE # 4 INDICATES A BUSINESS OCCUPANCY | | | AND THE REFERENECE TO CODE SECTION 306 WHICH IS | | | FACTORY? THEN UNDER THE HEADING NOTES OCCUPANCY TYPE ; | | | MERCANTILE, THIS IS A YOGA SSTUDIO, PROVIDE THE AREA ON | | | THE PLAN WHERE THE MERCANTILE AREA IS LOCATED. THIS | | | TRUELY APPEARS TO BE A EXERCISE ROOM WITHOUT EQUIPMENT | | | AND THE 15 SQ FT PER PERSON SHOULD BE USED PROVIDE WHAT | | | AREA WILL BE USED FOR YOGA AND WHAT AREA WILL BE USED | | | AS MERCANTILE FOR THE SALE OF GOODS, PROVIDE THE SQ FT | | | PER AREA AND OCCUPANT LOADS FOR EACH AREA. DEPENDING ON | | | THE SQ FOOTAGE THIS MAY BE A MIXED USE WILL THERE BE | | | SEPERATION BETWEEN OCCUPANCIES OR NON SEPERATED USE OR | | | ACCESSORY OCCUPANCIE? 508.4, 508.3 OR 508.2. | | | | | | 4) SHEET 1-A UNDER NOTES CLASSIFIES THIS BUILDING AS A | | | TYPE III BUILDING UNDER THE 2001 AND EARLIER CODE A | | | TYPE III BUILDING IDENTIFICATION WAS USED FOR A HEAVY | | | TIMBER BUILDING, PLEASE USE THE NOMENCLATURE UNDER THE | | | 2010 FBC-B TABLE 503.1 & TABLE 601. | | | | | | 5) THE WIND DESIGN CRITERIA IS NOT STATED TO THE 2010 | | | FBC-B AND WIND CRITERIA FOR A CATEGORY II BUILDING V | | | ULT 170 MPH, 3 SECOND GUST | | | | | | 6) UNDER THE WIND DESIGN CRITERIA THE EXPOSURE IS | | | LISTED AS "M" ? 2010 FBC-B 1609. 4.2 SURFACE ROUGHNESS | | | "C". | | | | | | 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-06-21 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-06-21 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-06-21 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2013-06-21 10:56:42 | BY RL | | 2013-06-17 14:32:29 | NEW SHEETS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-02-25 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-25 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-25 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2013-06-14 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-06-14 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-06-14 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2013-06-14 14:35:39 | 6300 S DIXIE HWY, SUITE 102 | | | PERMIT # 13020613 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO***** | | | | | | 1. PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS | | | WITH EXIT SIGNS. | | | | | | 2.EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2013-05-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-05-20 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-05-20 |
Time |
09:45 |
Sent To |
P |
|
| Notes |
| 2013-05-20 09:55:13 | 6300 SOUTH DIXIE HIGHWAY - SUITES 101 & 102 | | | PERMIT #13020613 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT (X2): PROVIDE TACTILE SIGNAGE AT ALL | | | REQUIRED EXIT DOORS WITH EXIT SIGNS. | | | | | | REPEAT COMMENT (X2): DOORS SERVING AN OCCUPANT LOAD OF | | | 50 OR MORE PERSONS SHALL SWING IN THE DIRECTION OF | | | EGRESS. | | | | | | REPEAT COMMENT (X1): SHEET A-1 INDICATES AN EXERCISE | | | AREA OF 490 SQ.FT.; HOWEVER, THE SCALED MEASUREMENT | | | INDICATES AN AREA OF 800 SQ.FT. (25 FT. X 32 FT.). | | | USING AN OCCUPANT LOAD FACTOR OF 15 SQ.FT. PER PERSON | | | (EXERCISE ROOM WITHOUT EQUIPMENT PER TABLE 7.3.1.2 NFPA | | | 101) RESULTS IN AN OCCUPANT LOAD OF 54 PERSONS.THE FIRE | | | CODE DEFINES AN ASSEMBLY OCCUPANCY AS AN OCCUPANCY USED | | | FOR THE GATHERING OF 50 OR MORE PERSONS FOR | | | DELIBERATION, WORSHIP, ENTERTAINMENT, EATING, DRINKING | | | OR SIMILAR USAGE. | | | | | | REPEAT COMMENT (X1): EVERY ASSEMBLY OCCUPANCY ROOM NOT | | | HAVING FIXED SEATS SHALL HAVE THE OCCUPANT LOAD OF THE | | | ROOM POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT | | | FROM THE ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE | | | NUMBER OF OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | REPEAT COMMENT (X1): SHEET A-1, A 1-HOUR FIRE-RATED | | | CEILING BARRIER IS NEEDED FOR THE STORAGE/WATER HEATER | | | AREA LOCATED BENEATH THE CONCRETE STAIRS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-04-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-06 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-06 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2013-04-06 13:21:05 | 6300 SOUTH DIXIE HIGHWAY - SUITES 101 & 102 | | | PERMIT #13020613 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: UPDATE THE CODE LIST TO REFERENCE THE | | | 2010 EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | | CONTAINS THE 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 | | | WITH FLORIDA AMENDMENTS. | | | | | | REPEAT COMMENT: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED | | | EXIT DOORS WITH EXIT SIGNS. | | | | | | REPEAT COMMENT: THE LOCK/LATCH RELEASING MECHANISM ON | | | ALL DOORS SHALL OPEN THE DOOR WITH NOT MORE THAN ONE | | | RELEASING OPERATION. THE RELEASING MECHANISM SHALL HAVE | | | AN OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED | | | UNDER ALL LIGHTING CONDITIONS. THE RELEASING DEVICE | | | SHOULD BE CAPABLE OF BEING OPERATED WITH ONE HAND AND | | | SHOULD NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR | | | TWISTING OF THE WRIST TO OPERATE PER SECTION 7.2.1.5.9 | | | OF NFPA 101 FLORIDA EDITION 2007. | | | | | | REPEAT COMMENT: DOORS SERVING AN OCCUPANT LOAD OF 50 OR | | | MORE PERSONS SHALL SWING IN THE DIRECTION OF EGRESS. | | | | | | REPEAT COMMENT: THE CORRECT OCCUPANCY TYPE NEEDS TO BE | | | DETERMINED BEFORE A THOROUGH AND COMPLETE PLAN REVIEW | | | CAN BE PERFORMED. THE PLANS INDICATE A BUSINESS | | | OCCUPANCY; HOWEVER, AN ASSEMBLY OCCUPANCY IS MORE | | | APPROPRIATE. THE FIRE CODE DEFINES AN ASSEMBLY | | | OCCUPANCY AS AN OCCUPANCY USED FOR THE GATHERING OF 50 | | | OR MORE PERSONS FOR DELIBERATION, WORSHIP, | | | ENTERTAINMENT, EATING, DRINKING OR SIMILAR USAGE. | | | | | | NEW COMMENT: SHEET A-1 INDICATES AN EXERCISE AREA OF | | | 490 SQ.FT.; HOWEVER, THE SCALED MEASUREMENT INDICATES | | | AN AREA OF 800 SQ.FT. (25 FT. X 32 FT.). USING AN | | | OCCUPANT LOAD FACTOR OF 15 SQ.FT. PER PERSON (EXERCISE | | | ROOM WITHOUT EQUIPMENT PER TABLE 7.3.1.2 NFPA 101) | | | RESULTS IN AN OCCUPANT LOAD OF 54 PERSONS. | | | | | | NEW COMMENT: EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING | | | FIXED SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM | | | POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM | | | THE ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE | | | NUMBER OF OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | NEW COMMENT: SHEET A-1, THE "HALL AREA" APPEARS TO BE A | | | LARGE OPEN AREA THAT IS NOT DESIGNATED AS ANY | | | PARTICULAR USE OR OCCUPANT LOAD. MORE INFORMATION (USE, | | | FURNITURE, ETC.) NEEDS TO BE PROVIDED. | | | | | | NEW COMMENT: SHEET A-1, A 1-HOUR FIRE-RATED CEILING | | | BARRIER IS NEEDED FOR THE STORAGE/WATER HEATER AREA | | | LOCATED BENEATH THE CONCRETE STAIRS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-03-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-03-02 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-03-02 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2013-03-02 19:30:10 | 6300 SOUTH DIXIE HIGHWAY - SUITES 101 & 102 | | | PERMIT #13020613 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PLAN ADDRESS DOES NOT INDICATE IF IT IS NORTH DIXIE | | | OR SOUTH DIXIE HIGHWAY. | | | | | | UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | PROVIDE A LIFE SAFETY PLAN SHOWING ALL EXITS, OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | SHEET A-1: THE BUILDING SITE LOCATION IS INCORRECTLY | | | SHOWN AS "S. MILITARY TRAIL." | | | | | | PROVIDE AN EXERCISE EQUIPMENT LAYOUT, YOGA MAT LAYOUT, | | | ETC. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | THE LOCK/LATCH RELEASING MECHANISM ON ALL DOORS SHALL | | | OPEN THE DOOR WITH NOT MORE THAN ONE RELEASING | | | OPERATION. THE RELEASING MECHANISM SHALL HAVE AN | | | OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED | | | UNDER ALL LIGHTING CONDITIONS. THE RELEASING DEVICE | | | SHOULD BE CAPABLE OF BEING OPERATED WITH ONE HAND AND | | | SHOULD NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR | | | TWISTING OF THE WRIST TO OPERATE PER SECTION 7.2.1.5.9 | | | OF NFPA 101 FLORIDA EDITION 2007. | | | | | | DOORS SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS | | | SHALL SWING IN THE DIRECTION OF EGRESS. | | | | | | THE CORRECT OCCUPANCY TYPE NEEDS TO BE DETERMINED | | | BEFORE A THOROUGH AND COMPLETE PLAN REVIEW CAN BE | | | PERFORMED. THE PLANS INDICATE BOTH A BUSINESS OCCUPANCY | | | AND "M" GROUP (MERCANTILE?); HOWEVER, AN ASSEMBLY | | | OCCUPANCY APPEARS TO BE MORE APPROPRIATE. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-25 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-05 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2013-06-25 08:44:40 | 6/25 ROUTED TO HM DESK | | | | | 2013-06-08 10:24:56 | *EXPEDITED* | | | B--1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-05-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-24 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-17 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2013-05-17 16:54:02 | EXPEDITED | | | GAVE TO JIM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-04-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-04-10 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-02 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2013-04-02 15:02:25 | EXPEDITED | | | B--11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-18 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-02-21 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2013-02-22 13:29:25 | SENT TO B11 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2013-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-20 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-20 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2013-05-20 07:12:00 | IMPACT FEE STAMP ZERO FEES DUE. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-04-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-10 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-10 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-01 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-01 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2013-03-01 09:55:31 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2013-06-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-06-25 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-06-25 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2013-06-25 16:59:39 | PASS PROVISO | | | PAGE M1.1 SHOW NEW CONDENSER STAND. | | | DETAIL # 2 PAGE M2.1 SHOW EXISTING | | | CONDENSER STAND. IF STAND IS NEW PROVIDE A DETAIL FROM | | | THE ENGINEER | | | SHOWING TIE DOWN TO THE ROOF AT FIRST INSPECTION. | | | PER SECTION 301.12 WIND RESISTANCE.2010 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-04-10 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-10 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-18 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-03-18 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2013-03-18 12:09:34 | PLANS DENIED | | | PROVIDE THE DUCT AND GRILL SIZE OF THE SUPPLY AND | | | RETURN | | | AND THE SUPPLY CFM .PER SECTION 107 FBC 2010 | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2013-06-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-06-17 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-06-17 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2013-06-17 14:36:11 | ***PROVISO*** | | | | | | PER ACCESSIBILITY 2010 HI/LO DRINKING FOUNTAINS ARE | | | REQUIRED. | | | 211.2 MINIMUM NUMBER. | | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | | 602.7. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2013-05-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-24 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-24 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2013-05-24 11:07:50 | PLUMBING PLAN REVIEW | | | PERMIT: 13020613 | | | ADD: 6300 S DIXIE HWY # 101 & 102 | | | CONT: ATANTIDA | | | TEL: (561) 290-1472 | | | | | | 2010 FLORIDA BUILDING CODE- PLUMBING W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RDREVIEW | | | DATE: MAY 24/ 2013 | | | ACTION: DENIED | | | | | | NOTE: IT HS BEEN DETERMINED BY BUILDING & FIRE THAT | | | THIS OCCUPANCY CLASSIFICATION IS A A3 ASSEMBLY | | | OCCUPANCY, GYM WITHOUT SPECTATOR SEATING. OCCUPANT LOAD | | | 490 SQ FT/ 15= 33 OCCUPANTS. | | | 2010 FBC-EXISTING BUILDING 901.3.1 PARTIAL CHANGE OF | | | OCCUPANCY CLASSIFICATION. WHERE A PORTION OF AN | | | EXISTING BUILDING IS CHANGED TO A NEW OCCUPANCY | | | CLASSIFICATION, SECTION 912 SHALL APPLY. | | | 2010 EXST BLDG CODE 910.1 INCREASED DEMAND. WHERE THE | | | OCCUPANCY OF AN EXISTING BUILDING OR PART OF AN | | | EXISTING BUILDING IS CHANGED SUCH THAT THE NEW | | | OCCUPANCY IS SUBJECT TO INCREASED OR DIFFERENT PLUMBING | | | FIXTURE REQUIREMENTS OR TO INCREASED WATER SUPPLY | | | REQUIREMENTS IN ACCORDANCE WITH THE FLORIDA BUILDING | | | CODE, PLUMBING, THE INTENT OF THE RESPECTIVE FLORIDA | | | BUILDING CODE, PLUMBING PROVISIONS SHALL BE COMPLIED | | | WITH FOR THE NEW OCCUPANCY. | | | | | | 1) THE 2010 FBC-P TABLE 403.1(1) MINIMUM REQUIRED | | | FIXTURES WILL REQUIRE A HANDICAPPED RESTROOM FOR EACH | | | SEX, A SERVICE SINK AND DRINKING FOUNTAIN, NOTE THE | | | 2010 ACCESSIBILITY CODE REQUIRES A HIGH -LOW TYPE | | | DRINKING FOUNTAIN TO MEET THE REQUIREMENTS OF : | | | 602.4 SPOUT HEIGHT. | | | SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE | | | THE FINISH FLOOR OR GROUND. | | | 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. | | | SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING | | | PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 | | | INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | PLUMBING: | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2013-04-09 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-04-09 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-04-03 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2013-04-09 08:51:08 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | PLUMBING REVIEW IS PENDING THE OUTCOME FOR THE | | | OCCUPANCY TYPE AND | | | OCCUPANT LOAD. PLEASE SEE BUILDING REVIEW COMMENTS. | | | | | | A BUSINESS OCCUPANCY WITH LESS THAN 3000 SQUARE FEET | | | WOULD ONLY REQUIRE ONE RESTROOM, AND WITH 15 OR LESS | | | OCCUPANTS WOULD NOT REQUIRE A HI/LOW DRINKING FOUNTAIN | | | (FBC | | | ACCESSIBILITY CODE 211.2) | | | FBC PLUMBING TABLE 403.1 | | | | | | ALSO, A YOGA STUDIO COULD BE AN ASSEMBLY OCCUPANCY. | | | THEN | | | SEPARATE FACILITIES ARE REQUIRED FOR EACH SEX, A HI/LOW | | | DRINKING FOUNTAIN (IF OCCUPANT LOAD IS OVER 15), AND A | | | SERVICE SINK. | | | FBC PLUMBING TABLE 403.1 AND 403.2 SEPARATE FACILITIES. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805?6692 | | | EMAIL [email protected] | | | FAX # 805?6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-02-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-02-27 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-02-27 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2013-02-27 15:45:44 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | MORE INFORMATION IS REQUIRED FOR THE OCCUPANCY TYPE AND | | | OCCUPANT LOAD. | | | SHEET A-1 SCOPE OF WORK NOTE 4 STATES GROUP B BUISNESS | | | UNDER NOTES STATES - GROUP M, WITH 35 OCCUPANTS. | | | BUSINESS OCCUPANCY WITH 35 OCCUPANTS WOULD REQUIRE 2 | | | RESTROOMS AND A HI/LOW DRINKING FOUNTAIN (FBC | | | ACCESSIBILITY CODE 211.2) UNLESS THESE ARE PROVIDED IN | | | THE BUILDING COMMON AREA. | | | FBC PLUMBING TABLE 403.1 WATER CLOSETS 1 PER 25 FOR THE | | | FIRST 50 OCCUPANTS. DRINKING FOUNTAIN REQUIRED FOR OVER | | | 15 OCCUPANTS. | | | | | | ALSO A YOGA STUDIO COULD BE AN ASSEMBLY OCCUPANCY. THEN | | | SEPARATE FACILITIES ARE REQUIRED FOR EACH SEX, A HI/LOW | | | DRINKING FOUNTAIN, AND A SERVICE SINK. | | | FBC PLUMBING 403.2 | | | | | | THIS OCCUPANCY DOES NOT APPEAR TO BE MERCANTILE AS | | | GROUP M IS FOR THE DISPLAY AND SALE OF MERCHANDISE AND | | | INVOLVES STOCKS OF GOODS, WARES OR MERCHANDISE | | | INCIDENTAL TO SUCH PURPOSES... | | | FBC 309.1 | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-26 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-02-26 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-02-26 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|