| Plan Review Stops For Permit 13020482 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-17 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-03-29 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2013-03-25 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-29 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-04 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-04 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2013-03-04 15:32:20 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION: | | | | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE | | | | | | SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 | | | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE | | | ROUTE). | | | | | | YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL, | | | PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS | | | RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE | | | PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN." | | | | | | HTTP://WWW.ADA.GOV/RESTRIPE.HTM | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2013-04-16 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-04-16 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2013-04-16 |
Time |
|
Sent To |
I |
|
| Notes |
| 2013-04-16 15:56:57 | PASSED WITH PROVISO: | | | | | | WHEEL STOPS AREA REQUIRED (6' WIDE MIN). |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2013-03-25 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-03-25 |
Time |
|
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2013-03-25 |
Time |
|
Sent To |
B |
|
| Notes |
| 2013-03-25 15:30:27 | PLEASE SUPPLY A LITTLE MORE DETAIL. | | | | | | MISSING PARKING DIMENSION, 9' WIDE X LENGHT? | | | | | | PLEASE SEE PLANNING'S COMMENTS | | | | | | PARKING COUNT SHOULD BE REVISED TO PROVIDE TOTAL | | | PARKING ON-SITE. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2013-03-04 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-03-04 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2013-03-04 |
Time |
|
Sent To |
I |
|
| Notes |
| 2013-03-04 09:00:04 | PLEASE ADDRESS CITY OF WPB PLANNING AND ZONING COMMENT. | | | | | | STRIPING WILL BE PERFORMED ON-SITE AND NOT IN 20' | | | ALLEYWAY. IF YOU WISH TO PAVE THE 20' ALLEY YOU MUST | | | OBTAIN A CITY ROW PERMIT. | | | | | | NEW ASPHALT SHALL NOT EXCEED THE CURRENT GRADE | | | ELEVATION. | | | | | | CATCH BASINS AND SWALES MUST BE PROTECTED AS PER NPDES | | | (POLLUTION PREVENTION PLAN) | | | | | | PERMIT DESCRIPTION DESCRIBES "AS PER COUNTY CODE", | | | PLEASE CHANGE TO CITY OF WPB CODE. | | | | | | DESCRIBE HOW THICK NEW MATERIAL WILL BE. | | | | | | PLEASE INCLUDE THE BUILDING'S FINISH FLOOR ELEVATION ON | | | PLANS. | | | | | | PLEASE INCLUDE IN YOUR PLAN SQUARE FEET OF PERVIOUS | | | AREAS VS IMPERVIOUS AREAS. | | | | | | NO ADA PARKING AREA SHOWN. ADA ACCESSABILITY TO | | | BUILDING MUST MEET U.S. DEPARTMENT OF JUSTICE AMERICANS | | | WITH DISABILITIES ACT STANDARDS. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-29 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-13 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2013-03-29 15:17:51 | 3/29 TO SH DESK | | 2013-03-13 09:05:28 | SENT TO ZONING BOX .JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-04 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-19 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2013-02-19 14:23:42 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2013-04-03 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2013-04-03 |
Time |
|
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2013-03-19 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-03-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2013-03-19 |
Time |
08:30 |
Sent To |
ENG |
|
| Notes |
| 2013-03-19 08:30:07 | ZONING PLAN REVIEW | | | REVIEW STATUS: FAILED | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | | | | ALTHOUGH THE RESUBMITTTAL INCLUDED PARKING STALL | | | LOCATIONS, THE APPLICANT MUST PROVIDE THE DETAIL OF THE | | | REQUIRED DIMENSIONS AS WELL AS THE PARKING RATIO | | | WARRANTED BY THE USE OF THE PROPERTY. THE NORTHERN MOST | | | PARKING STALL APPEART TO BE SUBSTANDARD FOR THE | | | ANGLE/TURNING RADII FOR CODE COMPLIANCE. IF YOU HAVE | | | ANY QUESTIONS PLEASE CONTACT ME AND/OR CONSULT THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS ONLINE | | | @WWW.MUNICODE.COM. | | | | | | MURRIAH DEKLE, MPA, PLANNER | | | PLANNING & ZONING DIVISION | | | TEL: (561) 822-1442 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-02-22 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-02-22 |
Time |
|
Rev Time |
|
| Received By |
mdekle |
Date |
2013-02-20 |
Time |
|
Sent To |
ENG |
|
| Notes |
| 2013-02-22 15:32:39 | PLAN IS MISSING CITY OF WPB STANDARD PARKING STALL | | | DETAIL. | | | | | | |
|
|