| Plan Review Stops For Permit 13020330 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-04-16 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-04-16 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-18 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-18 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2013-03-19 11:12:21 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- SPECIFY THE CALCULATED DESIGN PRESSURES FOR ALL NEW | | | WINDOWS AS REQUIRED BY SEC. R301.1 OF FBC-RESIDENTIAL. | | | ***NOTE: ACCORDING TO SEC. R301.2.1.4.3 THIS BUILDING | | | IS LOCATED IN EXPOSURE "C". TAKE THIS INTO | | | CONSIDERATION WHEN DOING THE CALCULATIONS. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR ALL STRUCTURAL FASTENERS SPECIFIED ON | | | THE FRAMING DETAILS REQUESTED ON ITEM #2 ABOVE. | | | ***NOTE; PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR. | | | | | | 3- SPECIFY ALL HURRICANE CONNECTORS AT THE ENDS OF THE | | | EACH STRUCTURAL MEMBER IN WINDOW OPENING DETAIL, | | | SECTION A AND SECTION B DETAILS TO VERIFY COMPLIANCE | | | WITH THE WIND LOADS OF SEC. R301.2.1.4.3. | | | | | | 4- DESIGN OF RECORD TO REVIEW AND APPROVE IN WRITING | | | THE WINDOW PRODUCT APPROVALS AND THE STRUCTURAL | | | CONNECTORS SPECIFIED ON FRAMING DETAILS AS REQUIRED BY | | | SEC. 107.3.4.1 CITY AMENDMENTS TO FBC. | | | | | | 5- PROVIDE MANUFACTURER'S CUT SHEETS FOR THE BEDROOM | | | EGRESS WINDOW SIZE SPECIFIED ON PLANS TO VERIFY | | | COMPLIANCE WITH SEC. R310. NOA 06-0608.03 SUBMITTED | | | DON'T SHOW SIZES AND SHOWS SINGLE HUNG WINDOW WITH THE | | | LOWER SASH SMALLER THAN THE TOP. NEED TO VERIFY EGRESS | | | CLEAR OPENING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2014-07-17 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
|
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
|
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-03-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-08 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-08 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-02-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-02-13 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-02-13 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-12 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2013-04-12 15:04:58 | SENT TO JULIO'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-03-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-18 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-13 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2013-03-04 16:34:17 | SENT TO R10 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-04-17 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-17 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-15 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-03-15 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2013-03-19 10:08:20 | PLANS DENIED | | | PROVIDE A FULL SET OF ENERGY CALCULATIONS | | | WITH THE PLANS PER SECTION M 104.3 SIZING | | | 2010 FBC RESIDENTIAL CODE | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-04-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-04-16 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-04-16 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-03-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-18 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-18 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2013-03-19 11:29:01 | RESIDENTIAL (R3) ALTERATION PLUMBING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROPOSED LOCATION OF NEW WATER HEATER IS NOT | | | ALLOWED. SEC. P2801.3 OF 2010 FBC-RESIDENTIAL. PROPOSED | | | LOCATION DOESN'T ALLOW FOR INSPECTION SERVICE, REPAIR | | | AND REPLACEMENT. SEE SEC. M1305. REVISE PLANS AS | | | REQUIRED. | | | | | | 2- REVISE PLUMBING RISER DIAGRAM. EACH WET-VENTED | | | FIXTURE DRAIN SHALL CONNECT INDEPENDENTLY TO THE | | | HORIZONTAL WET VENT AS REQUIRED BY SEC. P3108.1 OF 2010 | | | FBC-RESIDENTIAL. BATHROOM TUB DRAIN NEEDS TO CONNECT | | | DIRECTLY TO THE HORIZONTAL WET VENT. | | | | | | IF YOU HAVE ANY QUESTION, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-02-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-02-13 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-02-13 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|