Plan Review Details - Permit 13020323
Plan Review Stops For Permit 13020323
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2013-02-25 Cont ID  
Sent By shill Date 2013-02-25 Time 16:01 Rev Time 0.00
Received By shill Date 2013-02-25 Time 16:01 Sent To FIRE
Notes
2013-02-25 16:04:01NOT IN THE SPECIAL HAZARD FLOOD ZONE
 EXEMPT FROM FBC PER FS 489 (TEMPORARY CONSTRUCTION
 TRAILER PER APPLICATION)
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-02-27 Cont ID  
Sent By wjolin Date 2013-02-27 Time 12:35 Rev Time 0.00
Received By wjolin Date 2013-02-27 Time 11:57 Sent To  
Notes
2013-02-27 12:34:176610 NORTH JOG ROAD
 PERMIT #13020323
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE A LETTER OR NUMBER ON EACH CONSTRUCTION TRAILER
 TO ALLOW EMERGENCY RESPONDERS TO PROVIDE QUICK RESPONSE
 TO THE APPROPRIATE LOCATION. LETTERS OR NUMBERS SHALL
 BE ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES
 IN HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE
 BACKGROUND.
  
 PROVIDE STAIRS OR RAMP FOR ACCESS INTO THE TRAILERS.
 STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN
 HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A
 MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE
 ACCUMULATION OF WATER.
  
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR.
 HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND
 NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD,
 MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE
 LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE
 RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT
 NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A
 DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN
 2 INCHES.
  
 GUARDS, AT LEAST 42-INCHES TALL, SHALL BE PROVIDED AT
 THE OPEN SIDES OF STAIRS THAT EXCEED 30-INCHES ABOVE
 THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE OF A
 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF 34-INCHES. THE
 TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND
 BOTTOM ELEMENT OF THE GUARDRAIL SHALL PROHIBIT THE
 PASSAGE OF A 6-INCH DIAMETER SPHERE.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-02-27 Cont ID  
Sent By wjolin Date 2013-02-27 Time 12:35 Rev Time 0.00
Received By wjolin Date 2013-02-13 Time 15:23 Sent To  
Notes
2013-02-14 15:24:19SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-02-19 Cont ID  
Sent By eschneid Date 2013-02-19 Time 08:27 Rev Time 0.25
Received By eschneid Date 2013-02-15 Time 09:06 Sent To  
Notes
2013-02-15 09:06:16GAVE TO E.S. - MD


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved