Plan Review Details - Permit 13020302
Plan Review Stops For Permit 13020302
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-03-27 Cont ID  
Sent By jwitmer Date 2013-03-27 Time 13:20 Rev Time 0.00
Received By jwitmer Date 2013-03-27 Time 13:20 Sent To  
Notes
2013-03-27 13:28:13BUILDING PLAN REVIEW
 PERMIT: 13020302
 ADD: 426 10TH ST
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 MARCH 27/2013
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 (WINDOWS &
 EXTERIOR DOORS) SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 APPROVALS THAT WERE SUBMITTED:
 NOA: 11-1115.08 CGI SERIES ?110 SENTINEL? ALUMINUM
 SINGLE HUNG WINDOW LMI
 NOA: 10.0510.14 CGI SERIES ?110 SENTINEL? ALUMINUM
 MULLION LMI
  
 2) THE DOOR APPROVAL FL 11321-R1 NOT APPROVED, IS ONLY
 LISTED AS TESTED FOR LARGE MISSILE IMPACT, NO RATING
 FOR PRESSURES.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-03-15 Cont ID  
Sent By jwitmer Date 2013-03-15 Time 15:53 Rev Time 0.00
Received By jwitmer Date 2013-03-15 Time 14:15 Sent To  
Notes
2013-03-15 15:53:30BUILDING PLAN REVIEW
 PERMIT: 13020302
 ADD: 426 10TH ST
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 MARCH 15/2013
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) SEMI-COMPLIED. PLEASE RATE THE 2ND STORY EXIT
 CORRIDOR, ONLY ONE SIDE IS INDICATED AS A NEW RATED
 WALL.FIRST FLOOR AND SECOND FLOOR. INCLUDING THE UNDER
 SIDE OF THE STAIR STRINGER. PLEASE PROVIDE EITHER A
 GYPSUM OR UL LISTING FOR RATED WALL (FIRE PARTITIONS)
 FBC-B 709.4 AND FLOOR SYSTEMS, (FIRE BARRIERS) FBC-B
 707.3 FIRE-RESISTANCE RATING & 439.3 HORIZONTAL
 SEPERATION. THE FIRE-RESISTANCE RATING OF FIRE BARRIERS
 SHALL COMPLY WITH THIS SECTION.
 2010 707.5 CONTINUITY. FIRE BARRIERS SHALL EXTEND FROM
 THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY
 BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING,
 SLAB OR DECK ABOVE AND SHALL BE SECURELY ATTACHED
 THERETO. SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH
 CONCEALED SPACES, SUCH AS THE SPACE ABOVE A SUSPENDED
 CEILING.
 707.7 PENETRATIONS.PENETRATIONS OF FIRE BARRIERS SHALL
 COMPLY WITH SECTION 713.
 707.7.1 PROHIBITED PENETRATIONS. PENETRATIONS INTO AN
 EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE ALLOWED
 ONLY WHEN PERMITTED BY SECTION 1022.4 OR 1023.6,
 RESPECTIVELY.
 707.8 JOINTS. JOINTS MADE IN OR BETWEEN FIRE BARRIERS,
 AND JOINTS MADE AT THE INTERSECTION OF FIRE BARRIERS
 WITH UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR
 DECK ABOVE, SHALL COMPLY WITH SECTION 714.
  
 3)SEMI-NEW COMMENT RESTATED FOR A 1 & 2 FAMILY
 DWELLING: R314.2 SMOKE DETECTION SYSTEMS R314.3
 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
 BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL
 SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR
 DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN
 INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE
 ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR
 THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL
 IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL.
  
 NOTE IF THERE IS FOSSIL FUEL BURNING HEATERS, FIREPLACE
 OR APPLIANCE S THEN R315 CARBON MONOXIDE ALARMS ARE
 REQUIRED.
 R315.1 CARBON MONOXIDE PROTECTION.
 EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING
 BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS
 ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR
 APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER
 FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE
 AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL
 CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH
 ROOM USED FOR SLEEPING PURPOSES.
 EXCEPTION: THIS SECTION SHALL NOT APPLY TO EXISTING
 BUILDINGS THAT ARE UNDERGOING ALTERATIONS OR REPAIR
 UNLESS THE ALTERATION IS AN ADDITION AS DEFINED IN
 SECTION R315.1.3.
 R315.1.1 CARBON MONOXIDE ALARM.
 THE REQUIREMENTS OF SECTION R315.1 SHALL BE SATISFIED
 BY PROVIDING FOR ONE OF THE FOLLOWING ALARM
 INSTALLATIONS:
 (1) A HARD-WIRED CARBON MONOXIDE ALARM.
 (2) A BATTERY-POWERED CARBON MONOXIDE ALARM.
 (3) A HARD-WIRED COMBINATION CARBON MONOXIDE AND SMOKE
 ALARM.
 (4) A BATTERY-POWERED COMBINATION CARBON MONOXIDE AND
 SMOKE ALARM.
 R315.1.2 COMBINATION ALARMS.
 COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE
 LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING
 LABORATORY.
 WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE
 INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM
 DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT
 THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE
 ALARMS IN THE INDIVIDUAL UNIT.
  
  
 4) COMPLIED.
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) THE DOOR APPROVAL FL 11321-R1 IS ONLY LISTED AS
 TESTED FOR LARGE MISSILE IMPACT, NO RATING FOR
 PRESSURES.
  
 7-9) COMPLIED.
  
 10) SEMI-COMPLIED. THE PLANS NOW SHOW ATTIC ACCESS WITH
 A LIGHT FIXTURE ON THE REMOVALABLE LID, HOW WILL THE
 WIRE HAVE FLEX TO ALLOW FOR THE REMOVAL OF THE ACCESS
 HATCH. ATTIC ACCESS NOT SHOWN. 2010 FBC-B 1209.2 ATTIC
 SPACES. AN OPENING NOT LESS THAN 20 INCHES BY 30 INCHES
 (559 MM BY 762 MM) SHALL BE PROVIDED TO ANY ATTIC AREA
 HAVING A CLEAR HEIGHT OF OVER 30 INCHES (762 MM). A
 30-INCH (762 MM) MINIMUM CLEAR HEADROOM IN THE ATTIC
 SPACE SHALL BE PROVIDED AT OR ABOVE THE ACCESS OPENING.
  
 11) COMPLIED.
  
 12) NOT REQUIRED.
  
  
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-02-20 Cont ID  
Sent By jwitmer Date 2013-02-20 Time 08:55 Rev Time 0.00
Received By jwitmer Date 2013-02-20 Time 07:27 Sent To  
Notes
2013-02-20 08:34:35BUILDING PLAN REVIEW
 PERMIT: 13020302
 ADD: 426 10TH ST
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 FEB. 20/2013
 ACTION: DENIED
  
 1) THE CITY RECORDS INDICATE THIS PROPERTY IS LICENSED
 AS A 2 UNIT RENTAL, ADDING A THIRD UNIT WILL CREATE A
 CHANGE IN OCCUPANCY FROM A 1 & 2 FAMILY R-3 TO A 3 UNIT
 R-2 WHICH IS REVIEWED BY THE 2010 FBC-B & THE 2010
 EXISTING BLDG CODE. 2010 901.3 CHANGE OF OCCUPANCY
 CLASSIFICATION. WHERE THE OCCUPANCY CLASSIFICATION OF A
 BUILDING CHANGES, THE PROVISIONS OF SECTIONS 902
 THROUGH 912 SHALL APPLY. THIS INCLUDES A CHANGE OF
 OCCUPANCY CLASSIFICATION WITHIN A GROUP AS WELL AS A
 CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A
 DIFFERENT GROUP. EXT BLDG CODE 904.1 GENERAL.FIRE
 PROTECTION REQUIREMENTS OF SECTION 912 SHALL APPLY
 WHERE A BUILDING OR PORTIONS THEREOF UNDERGO A CHANGE
 OF OCCUPANCY CLASSIFICATION.EXT BLDG CODE 912.2 FIRE
 PROTECTION SYSTEMS. FIRE PROTECTION SYSTEMS SHALL BE
 PROVIDED IN ACCORDANCE WITH SECTIONS 912.2.1 AND
 912.2.2. EXT BLDG CODE 912.2.1 FIRE SPRINKLER SYSTEM.
 WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT
 REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE
 PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH
 CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH
 SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE
 CHANGE OF OCCUPANCY OCCURS. 2010 FBC-B F] 903.2.8 GROUP
 R. AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
 ACCORDANCE WITH SECTION 903.3 SHALL BE PROVIDED
 THROUGHOUT ALL BUILDINGS WITH A GROUP R FIRE AREA.\
  
 2) PLEASE PROVIDE EITHER A GYPSUM OR UL LISTING FOR
 RATED WALL (FIRE PARTITIONS) FBC-B 709.4 AND FLOOR
 SYSTEMS, (FIRE BARRIERS) FBC-B 707.3 FIRE-RESISTANCE
 RATING & 439.3 HORIZONTAL SEPERATION. THE
 FIRE-RESISTANCE RATING OF FIRE BARRIERS SHALL COMPLY
 WITH THIS SECTION.
 2010 707.5 CONTINUITY. FIRE BARRIERS SHALL EXTEND FROM
 THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY
 BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING,
 SLAB OR DECK ABOVE AND SHALL BE SECURELY ATTACHED
 THERETO. SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH
 CONCEALED SPACES, SUCH AS THE SPACE ABOVE A SUSPENDED
 CEILING.
 707.7 PENETRATIONS.PENETRATIONS OF FIRE BARRIERS SHALL
 COMPLY WITH SECTION 713.
 707.7.1 PROHIBITED PENETRATIONS. PENETRATIONS INTO AN
 EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE ALLOWED
 ONLY WHEN PERMITTED BY SECTION 1022.4 OR 1023.6,
 RESPECTIVELY.
 707.8 JOINTS. JOINTS MADE IN OR BETWEEN FIRE BARRIERS,
 AND JOINTS MADE AT THE INTERSECTION OF FIRE BARRIERS
 WITH UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR
 DECK ABOVE, SHALL COMPLY WITH SECTION 714.
 PLEASE RATE THE 2ND STORY EXIT CORRIDOR, ONLY ONE SIDE
 IS INDICATED AS A NEW RATED WALL.FIRST FLOOR AND SECOND
 FLOOR. INCLUDING THE UNDER SIDE OF THE STAIR STRINGER.
  
 3) 2010 EXST BLDG CODE 912.2.2 FIRE ALARM AND DETECTION
 SYSTEM. WHERE A CHANGE IN OCCUPANCY CLASSIFICATION
 OCCURS THAT REQUIRES A FIRE ALARM AND DETECTION SYSTEM
 TO BE PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE
 WITH CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING,
 SUCH SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE
 THE CHANGE OF OCCUPANCY OCCURS. EXISTING ALARM
 NOTIFICATION APPLIANCES SHALL BE AUTOMATICALLY
 ACTIVATED THROUGHOUT THE BUILDING. WHERE THE BUILDING
 IS NOT EQUIPPED WITH A FIRE ALARM SYSTEM, ALARM
 NOTIFICATION APPLIANCES SHALL BE PROVIDED THROUGHOUT
 THE AREA WHERE THE CHANGE OF OCCUPANCY OCCURS AND SHALL
 BE AUTOMATICALLY ACTIVATED.
 2010 FBC-B F] 907.2.9 GROUP R-2. FIRE ALARM SYSTEMS AND
 SMOKE ALARMS SHALL BE INSTALLED IN GROUP R-2
 OCCUPANCIES AS REQUIRED IN SECTIONS 907.2.9.1 AND
 907.2.9.2.
  
 4) SHEET A-1 UNIT NUMBER 3 IS INDICATED AS A 2 BEDROOM
 BUT THERE IS ONLY ONE BEDROOM THE OTHER ROOM IS TO
 SMALL FOR A BEDROOM AND IS LABELED A SEWING ROOM,
 PLEASE UPDATE THIS DISCREPANCY. 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) THE DOOR APPROVAL FL 11321-R1 IS ONLY LISTED AS
 TESTED FOR LARGE MISSILE IMPACT, NO RATING FOR
 PRESSURES.
  
 7) THE PRESSURES LISTED ON THE PLANS DO NOT INDICATE IF
 THESE ARE FOR WALL ZONES INTERIOR ZONES OR FOR THE ZONE
 5 CORNER ZONES, THE PLANS DEPICT OPENINGS WITHIN BOTH
 ZONES, PLEASE PROVIDE PRESSURES FOR BOTH ZONES.
 COMPONENTS AND CLADDING.
  
 8) SHEET A1 INDICATES THIS BUILDING AS A TYPE V
 CONSTRUCTION, PLEASE SEE 2010 FBC-B TABLE 503 EITHER VA
 OR VB.
  
 9) THE WINDOW PRODUCT APPROVAL PLEASE CIRCLE THE WINDOW
 SIZES TO BE INSTALLED, TYPE OF GLAZING, AND PRESSURES,
 PLEASE ALSO IDENTIFY WHICH OF THE MULLION SIZES THAT
 ARE TO BE INSTALLED. COMPONENT & CLADDING VS PRESSUES.
  
 10) ATTIC ACCESS NOT SHOWN. 2010 FBC-B 1209.2 ATTIC
 SPACES.
 AN OPENING NOT LESS THAN 20 INCHES BY 30 INCHES (559 MM
 BY 762 MM) SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A
 CLEAR HEIGHT OF OVER 30 INCHES (762 MM). A 30-INCH (762
 MM) MINIMUM CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE
 PROVIDED AT OR ABOVE THE ACCESS OPENING.
  
 11) 1210.3 SHOWERS. SHOWER COMPARTMENTS AND WALLS ABOVE
 BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED
 WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT
 LESS THAN 70 INCHES (1778 MM) ABOVE THE DRAIN INLET.
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-03-12 Cont ID  
Sent By rlecky Date 2013-03-12 Time 12:12 Rev Time 0.00
Received By rlecky Date 2013-03-12 Time 12:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-02-21 Cont ID  
Sent By rlecky Date 2013-02-21 Time 12:33 Rev Time 0.00
Received By rlecky Date 2013-02-21 Time 12:11 Sent To  
Notes
2013-02-21 12:33:3513020302
 426 10TH STREET
 MULTIFAMILY RENOVATION
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 PROVIDE AN ELECTRICAL RISER PLAN WITH A SINGLE SERVICE
 MAST AND SHOWING THE APPROPRIATE WIRE SIZES, METERS AND
 DISCONNECTS. INCLUDE A SUMMARY LOAD CALCULATION FOR THE
 ELECTRIC SERVICE. NEC 215.5
  
 A BUILDING OR OTHER STRUCTURE SERVED SHALL BE SUPPLIED
 BY ONLY ONE SERVICE. NEC 230.2
  
 MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN
 A BUILDING. NEC 230.70
  
 THE SERVICE DISCONNECTING MEANS SHALL CONSIST OF NOT
 MORE THAT SIX SWITCHES. NEC 230.71
  
 THE TWO TO SIX DISCONNECTS AS PERMITTED SHALL BE
 GROUPED IN ONE LOCATION. NEC 230.72
  
 AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 SERVICE GROUND. NEC 250.94
  
 INDICATE THE FAULT CURRENT CAPABILITY OF THE ELECTRICAL
 SERVICE DISCONNECTS AND PANEL BOARDS. NEC 110.9
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2013-03-27 Cont ID  
Sent By wjolin Date 2013-03-27 Time 11:41 Rev Time 0.00
Received By wjolin Date 2013-03-27 Time 11:32 Sent To  
Notes
2013-03-27 11:41:05THE RESUBMITTED DRAWINGS INDICATE THERE WILL BE TWO
 RESIDENTIAL UNITS IN LIEU OF THREE RESIDENTIAL UNITS;
 THEREFORE, THE LIFE SAFETY CODE IS NOT APPLICABLE TO 1
 OR 2 FAMILY DWELLINGS PER FLORIDA STATUTE 633. NO FIRE
 REVIEW REQUIRED.
 W. JOLIN

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-02-16 Cont ID  
Sent By wjolin Date 2013-02-16 Time 12:52 Rev Time 0.00
Received By wjolin Date 2013-02-16 Time 12:18 Sent To  
Notes
2013-02-16 12:52:20426 10TH STREET
 PERMIT #13020302
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO PERMIT RECORDS COULD BE LOCATED INDICATING THIS
 SINGLE FAMILY HOME WAS CONVERTED TO AN APARTMENT
 BUILDING; THEREFORE, A PERMIT FOR A CHANGE OF OCCUPANCY
 NEEDS TO BE SUBMITTED.
  
 PLANS, INCLUDING EXIT STAIRS, SHALL BE DESIGNED IN
 ACCORDANCE WITH NFPA 101 - LIFE SAFETY CODE (2009
 EDITION WITH FLORIDA AMENDMENTS) CHAPTER 30 TITLED,
 "NEW APARTMENTS."
  
 EXIT ENCLOSURES AND EXIT ENCLOSURE DOORS SHALL HAVE A
 MINIMUM 1-HOUR FIRE RESISTANCE RATING PER NFPA 101
 SECTION 30.2.2.1.2.
  
 PER NFPA 101 SECTION 30.3.5, NEW APARTMENT BUILDINGS
 SHALL BE PROTECTED BY AN APPROVED, SUPERVISED AUTOMATIC
 SPRINKLER SYSTEM. ENGINEERED FIRE SPRINKLER
 CONSTRUCTION DOCUMENTS ARE REQUIRED FOR A GENERAL
 BUILDING PERMIT. AFTER THE BUILDING PERMIT HAS BEEN
 ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT SHOP
 DRAWINGS (CONFORMING TO THE ENGINEERED CONSTRUCTION
 DOCUMENTS) FOR A SUB-PERMIT.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-03-27 Cont ID  
Sent By jwitmer Date 2013-03-27 Time 13:28 Rev Time 0.00
Received By jwitmer Date 2013-03-25 Time 10:51 Sent To  
Notes
2013-03-13 08:30:21B-13 NEW SURVEY BROUGHT IN MID-REVIEW FOR ZONING. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-03-27 Cont ID  
Sent By wlehnhar Date 2013-03-25 Time 09:30 Rev Time 0.00
Received By lmartine Date 2013-03-08 Time 12:01 Sent To  
Notes
2013-03-08 15:39:50EXPEDITED
 B--13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-03-27 Cont ID  
Sent By wlehnhar Date 2013-03-11 Time 09:29 Rev Time 0.00
Received By lmartine Date 2013-02-12 Time 16:40 Sent To  
Notes
2013-02-13 16:47:11EXPEDITED
 B--13

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-05-08 Cont ID  
Sent By hmoser Date 2013-05-08 Time 11:40 Rev Time 0.00
Received By hmoser Date 2013-05-08 Time 11:39 Sent To  
Notes
2013-05-08 11:41:00BATH EXHAUST ONLY
 PLAN REVIEW BY HM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-02-15 Cont ID  
Sent By lwagner Date 2013-02-15 Time 13:29 Rev Time 0.00
Received By lwagner Date 2013-02-15 Time 13:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2013-03-27 Cont ID  
Sent By aaponte Date 2013-03-27 Time 09:26 Rev Time 0.00
Received By aaponte Date 2013-03-27 Time 09:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2013-03-11 Cont ID  
Sent By aaponte Date 2013-03-11 Time 11:31 Rev Time 0.00
Received By aaponte Date 2013-03-11 Time 11:31 Sent To  
Notes
2013-03-11 11:32:01SEE COMMENTS FROM PREVIOUS REVIEWS.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-03-11 Cont ID  
Sent By aaponte Date 2013-03-11 Time 11:10 Rev Time 0.00
Received By aaponte Date 2013-03-11 Time 11:08 Sent To  
Notes
2013-03-11 11:31:201. PLEASE SUBMIT A SURVEY OF THE PROPERTY REFLECTIGN
 THE EXISTING CODITIONS.
 2. PLEASE INCLUDE PICTURES OF ALL THE ELEVATIONS TO
 COMPARE CHANGES ON PROPOSED ELEVATION.
 3. THE MAXIMUM DENSITY FOR THE PROPERTY IS 20 DWELLING
 UNITS PER ACRE.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.