| Plan Review Stops For Permit 13010847 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-15 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-15 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-03-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-06 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-06 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2013-03-06 17:18:22 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PLANS APPEAR CODE COMPLIANT. | | | | | | WHEN RESUBMITTING, PLEASE CREATE TWO (OR THREE) | | | COLLATED SETS OF PLANS WHICH INCLUDE THE MOST CURRENT | | | SHEETS FOR PERMIT ISSUANCE. REMOVED (OLD/PREVIOUS | | | VERSION) SHEETS ARE TO REMAIN WITH THE PERMIT | | | APPLICATION FOR REFERENCE AND SHOULD BE VOIDED. | | | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | 2. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED, | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-02-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-02-07 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-02-07 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2013-02-07 16:34:45 | BUILDING PLAN REVIEW | | | PERMIT: 13010847 | | | ADD: 550 S ROSEMARY # 158 | | | CONT: GREATER BAY INC | | | TEL: (813)267-7391 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | FEB. 07/2013 | | | ACTION: DENIED | | | | | | 1) PLEASE CORRECT THE ADDRESS ON THE PLANS TO 550 S | | | ROSEMARY # 158 ON BOTH THE PLANS AND ENERGY | | | CALCULATIONS. | | | | | | 2) PLEASE CORRECT THE MINIMUM TYPE CONSTRUCTION, THIS | | | BUILDING WAS BUILT UNDER THE 1994 SSBC CODE AS A TYPE | | | II UNDER THE 2010 FBCTHE COMPARISON IS A TYPE I-B. | | | PLEASE CORRECT ALL SHEETS THAT INDICATE THE 1994 SSBC | | | TYPE II. | | | | | | 3) SHEET A0.1 WINDICATES THE WIND DESIGN AS A 170 MPH | | | ZONE BUT DOES NOT PROVIDE THE EXPOSURE TYPE NOR DOES | | | THE PLANS PROVIDE PRESSURES POSITIVE/ NEGATIVE. | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | 3.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | | | 3.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | | | 3.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | | | 3.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | 3.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | | TABLE 1609.2(2) . | | | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP. | | | | | | 5) THE FLORIDA PRODUCT APPROVAL SUBMITTED FL 13407.R2 | | | SHEET 2 OF 10 PROVIDES TWO DESIN PRESSURES, ONE THAT IS | | | FLUSH WITH SILL AND THE OTHER IS NOT, WHICH UNIT IS TO | | | BE INSTALLED, THE PRESSURES ARE DIFFERENT. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 6) THE DOOR SCHEDULE IS FOUND ON A.01 DOOR # 6 IS A | | | FIRE RATED DOOR THAT LEADS INTO A EXIT PASSAGE WAY, NO | | | FIRE RATING HAS BEEN PROVIDED. 2010 FBC-B TABLE 715.4. | | | | | | 7) SHEET A.02 PROVIDES DETAILS FOR FIRE RATED WALLS, | | | BUT THE DETAILS DO NOT PROVIDE THE REQUIRED FIRE RATING | | | FOR THE STRUCTURAL COLUMNS SEE 2010 FBC-B TABLE 601 | | | PRIMARY FRAMING MEMBERS 2 HR FOR TYPE IB. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-03-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-14 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-14 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2013-02-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-22 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-22 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2013-02-22 16:07:13 | 13010847 | | | 550 S. ROSEMARY AVE. #158 | | | THE BRASS TAP | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | COMMENTS WHICH WERE NOT ADDRESSED ADEQUATELY WITHIN THE | | | SECOND SUBMITTAL. IF REQUIRED PLEASE CALL FOR FURTHER | | | CLARIFICATION. | | | | | | INDICATE THE SIZE OF THE PAD MOUNTED TRANSFORMER. NEC | | | 215.5 | | | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | AND FOR THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. | | | THE DESIGNER NEEDS TO PROVIDE THE WORDING, SIZE AND | | | LOCATIONS FOR ALL ELECTRICAL SAFETY SIGNAGE REQUIRED BY | | | THE NATIONAL ELECTRICAL CODE. NEC 110.22, 110.16, | | | 110.22 | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY (ON THE PLANS) | | | SHOWING COMPLIANCE WITH THE FLORIDA BUILDING ENERGY | | | CODE REQUIREMENTS. THE LIGHTING SUMMARY REQUIRED WILL | | | SHOW EACH AREA OF USE IN A TABLE FORMAT VERIFYING | | | COMPLIANCE WITH THE ENERGY CODE FOR THE AREA AND IN | | | TOTAL. FBC ENERGY CONSERVATION 505.3 | | | | | | VERIFY SERVICE CAPACITY FROM THE MAIN SERVICE FOR THIS | | | OCCUPANCY BY CALCULATION. INCLUDE EXISTING AND | | | POTENTIAL FUTURE OCCUPANCY LOADS WHICH WILL BE SUPPLIED | | | FROM THE EXISTING SERVICE. THE EXISTING SERVICE WHICH | | | FORMERLY SERVED PREDOMINANTLY BUSINESS USES IS NOW | | | BEING UTILIZED FOR SEVERAL NEW OR FUTURE RESTAURANTS. | | | SERVICE CAPACITY NEEDS TO BE VERIFIED. NEC 215.2 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-02-13 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-13 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-12 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2013-02-13 11:20:18 | 13010847 | | | 550 S. ROSEMARY AVE. #158 | | | THE BRASS TAP | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | PROVIDE AN ELECTRICAL RISER PLAN WHICH INCLUDES PANEL | | | ?HV?. INDICATE THE SIZE OF THE PAD MOUNTED TRANSFORMER. | | | PROVIDE A SYSTEM GROUNDING AND BONDING CONDUCTOR FOR | | | THE TRANSFORMER. NEC 215.5 | | | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | AND FOR THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. | | | NEC 110.22, 110.16, 110.22 | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY SHOWING COMPLIANCE | | | WITH THE FLORIDA BUILDING ENERGY CODE REQUIREMENTS. FBC | | | ENERGY CONSERVATION 505.3 | | | | | | PROVIDE SAFE WORKING CLEARANCES AND DEDICATED WORKING | | | SPACE AT ALL ELECTRICAL PANEL BOARDS AND TRANSFORMERS. | | | INDICATE LOCATION OF TRANSFORMERS. PROVIDE A STRUCTURAL | | | SUPPORT DETAIL FOR WALL OR CEILING MOUNTED | | | TRANSFORMERS. NEC 110.26, 240.24 | | | | | | ALL RECEPTACLES LOCATED WITHIN SIX FEET OF A SINKS MUST | | | BE GFCI PROTECTED. NEC 210.8 | | | | | | INDICATE THE REQUIRED SAFE CLEARANCES TO THE CEILING | | | FANS. NEC 110.3 | | | | | | PROVIDE A STRUCTURAL DETAIL FOR SUPPORT OF THE HANGING | | | TELEVISIONS. FBC 1604.1 | | | | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR VOICE/DATA, | | | CABLE, POS, AND FIRE ALARM SYSTEMS. | | | | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-03-20 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-03-19 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2013-03-19 14:42:34 | 550 SOUTH ROSEMARY AVENUE - SUITE #158 | | | PERMIT #13010847 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT (X2): ENGINEERED FIRE SPRINKLER | | | CONSTRUCTION DOCUMENTS ARE REQUIRED FOR A GENERAL | | | BUILDING PERMIT. AFTER THE BUILDING PERMIT HAS BEEN | | | ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT SHOP | | | DRAWINGS (CONFORMING TO THE ENGINEERED CONSTRUCTION | | | DOCUMENTS) FOR A SUB-PERMIT. SECTION 105.3.1.2(2) OF | | | THE FLORIDA BUILDING CODE REQUIRES SEALED FIRE | | | PROTECTION CONSTRUCTION DOCUMENTS FOR THE DESIGN OR | | | ALTERATION OF 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER | | | FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-02-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-02-25 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-02-25 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2013-02-25 13:09:28 | 550 SOUTH ROSEMARY AVENUE - SUITE #158 | | | PERMIT #13010847 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: ENGINEERED FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. SECTION 105.3.1.2(2) OF THE FLORIDA | | | BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER FLORIDA | | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-02-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-02-02 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-02-02 |
Time |
19:10 |
Sent To |
|
|
| Notes |
| 2013-02-02 19:27:49 | 550 SOUTH ROSEMARY AVENUE - SUITE #158 | | | PERMIT #13010847 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO | | | THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION | | | DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. SMOKING | | | SHALL BE PROHIBITED EXCEPT IN DESIGNATED EXTERIOR | | | AREAS. ALL OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL | | | HAVE "NO SMOKING" SIGNS POSTED. WHERE SMOKING IS | | | PERMITTED, SAFE RECEPTACLES FOR SMOKING MATERIALS SHALL | | | BE PROVIDED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING (FAX: 561-804-4774) AND | | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | | 500 NORTH DIXIE HIGHWAY. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | ENGINEERED FIRE SPRINKLER CONSTRUCTION DOCUMENTS ARE | | | REQUIRED FOR A GENERAL BUILDING PERMIT. AFTER THE | | | BUILDING PERMIT HAS BEEN ISSUED, THE SUBCONTRACTORS CAN | | | THEN SUBMIT SHOP DRAWINGS (CONFORMING TO THE ENGINEERED | | | CONSTRUCTION DOCUMENTS) FOR A SUB-PERMIT. SECTION | | | 105.3.1.2(2) OF THE FLORIDA BUILDING CODE REQUIRES | | | SEALED FIRE PROTECTION CONSTRUCTION DOCUMENTS FOR THE | | | DESIGN OR ALTERATION OF 50 OR MORE AUTOMATIC FIRE | | | SPRINKLERS. PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS | | | SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER | | | SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE | | | TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR | | | EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN | | | DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT | | | FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION | | | SUCH AS PRE-ENGINEERED SYSTEMS. | | | | | | SHEET A1.1: PROVIDE FLOOR PAINT OR BARRIER AT OUTSIDE | | | PATIO INDICATING THAT THIS IS A DESIGNATED EXIT PATH | | | FROM INTERIOR EXIT DOOR #8 TO THE EXTERIOR GATE. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-20 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-19 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2013-03-19 15:39:28 | INCOMING SENT TO FIRE DESK FIRE SPRINKLER PLANS FOR | | | MASTER. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-20 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-11 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2013-03-12 12:50:22 | EXPEDITED, 3RD RUN | | | C--5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-06 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2013-02-21 14:37:24 | EXPEDITED, 2ND RUN | | | C--5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-02-14 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-01-29 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2013-01-29 16:19:43 | EXPEDITED | | | C--5 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
N |
Date |
2013-03-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-18 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-18 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2013-03-18 14:54:45 | IMPACT FEE ASSESSMENT NO FEES DUE. SEE MUNICIPAL IMPACT | | | FEE QUESTIONAIRE. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-15 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-15 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-03-15 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-03-15 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2013-03-15 16:57:14 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-03-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-03-06 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-03-06 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2013-03-06 17:40:40 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | | PLEASE CALL 561-233-5025 FOR MORE INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-02-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-02-25 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-02-25 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-02-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-02-01 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-02-01 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2013-02-01 15:22:32 | MECHANICAL PLANS DENIED | | | 1) NOTE 21 ON PAGE M1.2 REQUEST THAT YOU PAINT EXPOSED | | | DUCT. | | | FIBERGLASS, FLEX OR DUCT WRAP CAN NOT BE PAINTED. | | | PER SECTION 603.5 NONMETALLIC DUCT. AND THE MANUFACTURE | | | OF THE DUCT . | | | 2) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROLS. | | | FOR OUT DOOR AIR AND EXHAUST 2010 FBC (M) . | | | 3) ADDRESS ON THE ENERGY CALCULATION AND PLANS DO NOT | | | MATCH. | | | 4) PROVIDE PRODUCT APPROVALS FOR THE FRESH AIR AND | | | EXHAUST | | | OUTSIDE LOUVERS. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-03-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-03-01 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-03-01 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-02-05 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-02-05 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-02-05 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2013-02-05 10:13:06 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. THE BAR EQUIPMENT (HAND SINKS, ICE BINS, FLOOR | | | DRAINS, BEER RINSE, ETC.) ARE NOT REQUIRED TO BE | | | CONNECTED TO THE GREASE SYSTEM. PLEASE CONNECT TO THE | | | SANITARY. PLEASE LEAVE THE KITCHEN ON THE INTERCEPTOR. | | | FBC 2010 PLUMBING 2010 1003.2 APPROVAL: | | | .....WASTES THAT DO NOT REQUIRE TREATMENT OR SEPARATION | | | SHALL NOT BE DISCHARGED INTO ANY INTERCEPTOR OR | | | SEPARATOR. | | | | | | 2. A VENT IS REQUIRED BETWEEN THE LAST 2 WATER CLOSETS | | | (THE H.C. CLOSETS) ON THE CIRCUIT VENT SYSTEM. | | | 911.2 VENT CONNECTION. | | | THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | | THE TWO MOST UPSTREAM FIXTURE DRAINS. THE VENT SHALL | | | CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE INSTALLED | | | IN ACCORDANCE WITH SECTION 905. THE CIRCUIT VENT PIPE | | | SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL OR | | | WASTE.911.2 VENT CONNECTION. | | | | | | 3. SHEET P1.1 THE COLD WATER MAIN WILL BE REQUIRED TO | | | BE 1" TO THE LAST FIXTURE IN THE RESTROOMS PER TABLE | | | 603.1 (OR PLEASE SHOW ALL FLOW CALCULATIONS ON PLAN). | | | 604.1 GENERAL. | | | THE DESIGN OF THE WATER DISTRIBUTION SYSTEM SHALL | | | CONFORM TO ACCEPTED ENGINEERING PRACTICE. METHODS | | | UTILIZED TO DETERMINE PIPE SIZES SHALL BE APPROVED. | | | | | | 4. PLEASE INCLUDE THE LOCATION AND SIZE OF THE WATER | | | HEATER. | | | 107.3.5.1.3 PLUMBING 5. WATER HEATERS | | | | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-02-14 |
|
|
Cont ID |
|
| Sent By |
Eschneid |
Date |
2013-02-14 |
Time |
12:01 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2013-02-14 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2013-02-14 13:38:50 | PASSED | | | | | | ****PLEASE BE AWARE THAT THIS USE IS AN ALCOHOLIC | | | BEVERAGE ESTABLISHMENT****** | | 2013-01-30 10:06:38 | 1/28/13 |
|
|