| 2013-01-29 10:54:26 | BUILDING PLAN REVIEW |
| | PERMIT: 13010779 |
| | ADD: 7679 DAHLIA CT. |
| | CONT: GARABAR, INC. |
| | TEL: (561)337-6798 |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) GARABAR ROOFING CONTRACTOR HAS ELECTED TO USE THE |
| | COUNTY ROOFING FORM AS PART OF THE ROOFING REVIEW. |
| | ROOFING FORM 100 SECTION D FOR FLAT ROOF APPLICATION |
| | LIST THE LOCATION AS EXPOSURE "C" ROOF HEIGHT OF 28 FT |
| | , LISTED ON THE FORM THE MINIMUM WIND UPLIFT PRESSURES |
| | FOR P1 (FIELD) IS -44 PSF, P2 ( PERIMETER) -74 PSF & P3 |
| | CORNERS |
| | -111 PSF. |
| | |
| | THE ENGINEERS PRESSURES ARE LOW, FOR EXPOSURE B AND A |
| | MEAN ROOF HEIGHT OF LESS THAN 20 FT. PLEASE REVIEW |
| | FORMS AND UPDATE APPROPRIATELY. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |