| Plan Review Stops For Permit 13010622 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-03-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-12 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-12 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-02-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-02-08 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-08 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2013-02-08 17:26:08 | RESIDENTIAL (R3) REPAIRS BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR NEW ROOF TO BE INSTALLED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2013-04-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-04-10 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-10 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2013-04-10 17:18:46 | OK PER D HARVEY - SEE SIGNATURE/STAMPS ON PLAN | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2013-03-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-08 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-08 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2013-03-08 17:14:58 | 13010622 | | | 5014 PINEWOOD AVE. | | | RESIDENTIAL REPAIR | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | THE SUBMITTED ELECTRIC SERVICE RISER IS MISSING THE | | | GROUNDING CONDUCTOR, GROUNDING ELECTRODE, THE | | | INTERSYSTEM BOND AND THE ELECTRICAL SERVICE WIRE SIZES. | | | NEC 215.5, 250.94 | | | | | | PROVIDE PANEL SCHEDULES FOR EACH UNIT. NEC 215.5 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-02-11 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-11 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-11 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2013-02-11 10:35:31 | 13010622 | | | 5014 PINEWOOD AVE. | | | RESIDENTIAL REPAIR | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | IF THE RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE | | | OR A FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. 2010 | | | FBC R314, 315 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | | GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12 | | | | | | THE BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH | | | CIRCUIT. NEC 210.11 (C) (3) | | | | | | PROVIDE AN ELECTRIC SERVICE RISER SHOWING THE PANEL, | | | MAIN BREAKER, CONDUIT AND FEEDERS. PROVIDE PANEL | | | SCHEDULES EACH UNIT. NEC 215.15 | | | | | | A SEPARATE PERMIT IS REQUIRED FOR EACH STRUCTURE. | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-04-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-04-12 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-04-04 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2013-04-05 15:22:14 | RE-SUBMITTAL SENT TO ELECTRICAL SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-12 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-27 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-11 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-11 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-23 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2013-01-31 17:20:55 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-02-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-02-11 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-11 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-07 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2013-01-23 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2013-01-28 11:21:31 | ENTERED ZONING STOP BY MISTAKE. JG. |
|
|