Plan Review Details - Permit 13010620
Plan Review Stops For Permit 13010620
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-01-28 Cont ID  
Sent By rmcdouga Date 2013-01-28 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2013-01-28 Time 07:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-01-28 Cont ID  
Sent By rmcdouga Date 2013-01-28 Time 07:46 Rev Time 0.00
Received By rmcdouga Date 2013-01-28 Time 07:03 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2013-01-28 Cont ID  
Sent By rmcdouga Date 2013-01-28 Time 07:05 Rev Time 0.00
Received By rmcdouga Date 2013-01-28 Time 07:05 Sent To  
Notes
2013-01-28 07:06:24A SEPARATE PERMIT,APPLICATION AND REVIEW IS REQUIRED
 FOR THE GAS PERMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-30 Cont ID  
Sent By rmcdouga Date 2013-01-30 Time 07:30 Rev Time 0.00
Received By rmcdouga Date 2013-01-29 Time 17:18 Sent To  
Notes
2013-01-29 17:18:24GAVE TO ROBBIE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-28 Cont ID  
Sent By mdekle Date 2013-01-28 Time   Rev Time 0.00
Received By mdekle Date 2013-01-23 Time 17:49 Sent To  
Notes
2013-01-25 17:49:51EXPEDITED 1/25/13
 GAVE TO ROBBIE

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-01-30 Cont ID  
Sent By rmcdouga Date 2013-01-30 Time 07:30 Rev Time 0.00
Received By rmcdouga Date 2013-01-30 Time 07:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-01-28 Cont ID  
Sent By rmcdouga Date 2013-01-28 Time 08:10 Rev Time 0.00
Received By rmcdouga Date 2013-01-28 Time 07:04 Sent To Z
Notes
2013-01-28 09:08:152010 FBC
  
 DENIED BY PLUMBING
  
 1) THE MANUFACTURER'S SPECIFICATIONS FOR THE 1 HP
 HAYWARD 2 SPEED POOL PUMP MODEL # SP2607X102S HAS A
 FLOW RATE OF 85 GPM WITH A 20' TDH. THE PLANS
 INCORRECTLY SPECIFY 75 GPM AT 19.3 TDH AND 2" SUCTION
 PIPING. THE FLOW WILL EXCEED THE ALLOWABLE 8 FT PER
 SECOND VELOCITY IF 2" SUCTION PIPE IS USED WITH A FLOW
 RATE OF 85 GPM. PLEASE CORRECT. FBCR 4101.6.3 AND
 ANSI/APSP-06
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2013-01-28 Cont ID  
Sent By rmcdouga Date 2013-01-28 Time 08:21 Rev Time  
Received By mdekle Date 2013-01-28 Time   Sent To  
Notes
***NONE***