Plan Review Details - Permit 13010507
Plan Review Stops For Permit 13010507
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-28 Cont ID  
Sent By jwitmer Date 2013-01-28 Time 14:05 Rev Time 0.00
Received By jwitmer Date 2013-01-28 Time 14:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-01-24 Cont ID  
Sent By jwitmer Date 2013-01-24 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2013-01-24 Time 15:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-01-28 Cont ID  
Sent By rlecky Date 2013-01-28 Time 11:42 Rev Time 0.00
Received By rlecky Date 2013-01-28 Time 11:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-01-22 Cont ID  
Sent By rlecky Date 2013-01-22 Time 11:26 Rev Time 0.00
Received By rlecky Date 2013-01-22 Time 11:26 Sent To  
Notes
2013-01-22 11:38:4813010507
 3901 S. FLAGLER DR. #601
 INTERIOR KITCHEN AND BATH REMODEL
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 SHOW LOCATION OF THE ELECTRICAL PANEL WITH REQUIRED
 SAFE WORKING CLEARANCES. NEC 110.26
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12
 INCLUDE THE SIZE OF THE BRANCH CIRCUIT, WIRING METHOD
 AND LOCATION OF DISCONNECTS FOR NEW EQUIPMENT. FBC
 107.1
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 NOTE: AN ELECTRIC PERMIT IS REQUIRED.
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-01-28 Cont ID  
Sent By jwitmer Date 2013-01-28 Time 14:05 Rev Time 0.00
Received By jwitmer Date 2013-01-28 Time 11:54 Sent To  
Notes
2013-01-28 11:54:44TO JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-28 Cont ID  
Sent By rlecky Date 2013-01-28 Time 11:42 Rev Time 0.00
Received By rlecky Date 2013-01-28 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-24 Cont ID  
Sent By jwitmer Date 2013-01-24 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2013-01-22 Time 11:22 Sent To  
Notes
2013-01-22 11:26:37B08

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-01-23 Cont ID  
Sent By lwagner Date 2013-01-23 Time 11:45 Rev Time 0.00
Received By lwagner Date 2013-01-23 Time 10:48 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved