| Plan Review Stops For Permit 13010383 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-03-28 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2013-03-29 09:21:28 | ALTHOUGH STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE, THIS | | | REMODEL IS NOT A SUBSTANCIAL IMPROVEMENT. | | | | | | THE ROOFING PRODUCT APPROVAL THAT WAS SUBMITTED IS | | | MIAMI DADE NOA NO. 07-1120.13 FOR CEDAR SHAKES & | | | SHINGLES. A REVISION IS REQUIRED FOR THE PRODUCT | | | APPROVALS FOR THE BUILT-UP ROOFING THAT WAS NOT | | | SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-20 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-03-19 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2013-03-20 09:13:44 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE TWO STRUCTURAL SHEETS THAT WERE SUBMITTED HAVE | | | COPIED SIGNATURES OF THE ENGINEER IN THE TITLE BLOCK. | | | FAC 61G15-23.002 REQUIRES THE ENGINEER'S ORIGINAL WET | | | SIGNATURE. SUBMIT SIGNED AND SEALED STRUCTURAL | | | DRAWINGS. | | | | | | 2) ON SHEET 2 OF THE STRUCTURAL DRAWINGS WALL SECTION 1 | | | SPECIFIES 1 X 8 T&G FOR THE ROOF SHEATHING. THIS IS NOT | | | ACCEPTABLE FOR 36" RAFTER SPACING. FBCR TABLE R803.1 | | | REQUIRES 1-1/2" T & G FOR THIS SPAN. PLEASE CORRECT. | | | NOTE: THE SPECIFIED FASTENERS WILL NEED TO BE REVISED | | | FOR THE THICKER LUMBER SHEATHING. | | | | | | 3) SPECIFY THE ROOF PITCH ON THE PLANS. FBCR905.7.2 | | | WOOD SHINGLES REQUIRE A MINIMUM 3/12 SLOPE AND 905.8.2 | | | WOOD SHAKES REQUIRE A MINIMUM 4/12 SLOPE. | | | | | | 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | CASEMENT WINDOWS, FIXED GLASS WINDOWS AND BUILT-UP | | | ROOFING, SPECIFIED ON THE PLANS, THAT HAVE BEEN | | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. DCA | | | RULE 9N-3 AND CITY AMENDMENTS 107.3.4.1 | | | | | | 5) THE STRUCTURAL DRAWINGS SPECIFY THREADED RODS | | | ATTACHING THE RAFTERS AND GABLE FRAMING MEMBERS. | | | HOWEVER, THE DRAWINGS APPEAR TO SHOW LAG BOLTS OR LARGE | | | SCREWS BECAUSE THEY DO NOT APPEAR TO EXTEND ALL THE WAY | | | THROUGH THE LUMBER IN ORDER TO BE BOLTED TOGETHER. | | | PLEASE CLARIFY. CITY AMENDMENTS 107.2.1 AND FBC R301.1 | | | | | | 6) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | | BY THE OWNER/AGENT. FBC ENERGY CONSERVATION SECTION | | | 405.4 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-01-31 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-01-29 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2013-01-31 14:16:53 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION SECTION | | | 401.2 FOR THE NEW BREAKFAST ROOM. | | | | | | 2) SHOW COMPLIANCE WITH FBC R314.3.1 FOR SMOKE ALARMS. | | | | | | 3) UPDATE GENERAL NOTES ON SHEET CVR TO REFLECT THE | | | 2010 FBC AND THE REFERENCED STANDARDS IN CHAPTER 43 OF | | | FBC RESIDENTIAL. ASTM C94-07, ACI - 08 EDITIONS, AND | | | 2010 FBC FOR #S 40 AND 41. | | | | | | 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | EXTERIOR DOORS, WINDOWS, ROOFING MATERIAL, TRUSS | | | ANCHORS AND CONNECTORS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 5) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE PROJECT. CITY AMENDMENTS 107.3.4.1. | | | | | | 6) PROVIDE STRUCTURAL DETAILS FOR THE CONSTRUCTION OF | | | THE ARCH AT THE GABLE OF THE SECOND FLOOR BALCONY. CITY | | | AMENDMENTS 107.2.1 | | | | | | 7) THE PLANS SHOW A FRENCH DOOR AT THE REAR OF THE | | | BREAKFAST ROOM THAT OPENS OUT OVER THE EXISTING POOL. | | | INDICATE HOW THIS WILL COMPLY WITH FBCR 311.3 WHICH | | | REQUIRES A FLOOR OR LANDING ON EACH SIDE OF EACH | | | EXTERIOR DOOR. | | | | | | 8) SHOW COMPLIANCE WITH FBCR 4101.17 FOR RESIDENTIAL | | | SWIMMING POOL BARRIER REQUIREMENT AT NEW ADDITION. | | | | | | 9) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WHICH | | | REQUIRES THE ADDITION TO HAVE A FINISH FLOOR ELEVATION | | | OF 7'-6" BFE WHICH INCLUDES A 6" FREEBOARD REQUIRED BY | | | THE CITY'S MUNICIPAL CODE. SPECIFY THE FINISH FLOOR | | | ELEVATION ON THE PLANS AND PROVIDE AN ELEVATION | | | CERTIFICATE WITH THE PROPOSED FINISH FLOOR ELEVATION. | | | FBCR 322 AND CITY FLOOD PLAIN ORDINANCE | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-03-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-08 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-08 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-02-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-01 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-01 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2013-02-01 12:12:20 | 13010383 | | | 3024 WASHINGTON ROAD | | | RESIDENTIAL ADDITION | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | | GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12 | | | | | | RECEPTACLES IN THE BREAKFAST ROOM SHALL BE SERVED FROM | | | ONE OR MORE 20 AMPERE BRANCH CIRCUITS. NEC 210.52 | | | (B)(1) | | | | | | BALCONIES, DECKS AND PORCHES SHALL HAVE AT LEAST ONE | | | GFCI PROTECTED RECEPTACLE OUTLET. NEC 210.52 (E)(3) | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-02-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-02-15 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-02-15 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2013-02-13 17:18:37 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-01-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-01-17 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-01-17 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-03-25 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2013-03-25 14:20:32 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-20 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-02-13 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2013-02-13 17:11:35 | SENT TO R9 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-01 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-15 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2013-01-17 17:04:56 | SENT TO R7 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2013-04-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-04-01 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-04-01 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-03-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-20 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-03-20 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2013-03-20 09:45:53 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. | | | ONE SET OF APPROVED PLANS ARE TO BE SIGNED OUT AND | | | TAKEN TO PALM BEACH COUNTY FOR REVIEW. THE REVIEWED | | | PLANS WITH THE IMPACT REVIEW STAMP ON THEM AND A COPY | | | OF THE PAID RECEIPT ARE TO BE RETURNED TO THE WEST PALM | | | BEACH BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT IS | | | ISSUED. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-01-31 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-01-31 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2013-01-31 10:32:41 | IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2013-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-03-28 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-03-28 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2013-03-28 11:24:19 | NO MECHANICAL PERMIT WAS APPLIED FOR AT THIS TIME. A | | | SEPARATE PERMIT, APPLICATION AND REVIEW IS REQUIRED FOR | | | A MECHANICAL PERMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-03-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-03-15 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2013-03-15 15:24:34 | NO MECHANICAL PLANS SUBMITTED. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-02-15 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-02-15 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-02-15 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2013-02-13 17:18:58 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-01-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-01-17 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-01-17 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2013-01-17 15:35:09 | TO JULIO -FM |
|
|