| Plan Review Stops For Permit 13010358 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-06-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-04 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-06-04 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2013-06-04 11:13:45 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- ENGINEER OF RECORD TO REVISE ROOF TILE FASTENING | | | INFORMATION ON PRODUCT APPROVAL TABLE ON SHEET A2.0 TO | | | MATCH PRODUCT APPROVAL SUBMITTED. THE DESIGN PRESSURES | | | AND PADDY SIZE DON'T MATCH PRODUCT APPROVAL SUBMITTED. | | | | | | 2- PROVIDE BUILDING INSPECTOR WITH COMPLETE TRUSS | | | PACKAGE WHEN REQUESTING ROOF FRAMING INSPECTION. TRUSS | | | PACKAGE TO HAVE: A)TRUSS ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. B) ENGINEER TITLE BLOCK WITH NAME OF | | | PROJECT, NAME OF ENGINEER, ADDRESS, LICENSE NUMBER AND | | | DATE OF SIGNING AND SEALING DRAWINGS . | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-03-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-27 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-27 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2013-03-27 15:34:59 | RESIDENTIAL (R3) ADDITION BUILDING REVIEW CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF COVERING. | | | | | | ***NOTE: PLANTATION ROOF TILE NOA 10-0804.15 SUBMITTED | | | WAS SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE | | | WEBSITE AND DOWNLOAD CURRENT NOA. | | | | | | B) SELF-ADHESIVE UNDERLAYMENT FOR NEW CONCRETE ROOF | | | TILE AS SPECIFIED BY THE ENGINEER OF RECORD. | | | | | | ***NOTE: BORAL ROOF UNDERLAYMENTS FL14317-R1 SUBMITTED | | | CAN'T BE USED IN THIS BUILDING. ACCORDING TO SEC. | | | 5.5.2.1 OF THE FLORIDA PRODUCT APPROVAL SUBMITTED THE | | | MAXIMUM DESIGN PRESSURE IS -45PSF. NEED PRODUCT | | | APPROVAL THAT MEETS OR EXCEEDS DESIGN PRESSURES FOR | | | ROOF PERIMETER AND CORNER AREAS. SEE PLANS FOR | | | CALCULATED DESIGN PRESSURES THAT NEED TO BE MET. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL OF THE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | TO FBC. | | | | | | 3- ENGINEER OF RECORD TO PROVIDE COMPLETE ROOF ASSEMBLY | | | SPECIFICATIONS AS REQUIRED BY SEC. 107.2.1.2 CITY | | | AMENDMENTS. SPECIFY ROOF TILE FASTENING METHOD. | | | DRAWINGS SUBMITTED DON'T SPECIFY TILE FASTENING METHOD. | | | | | | 4- CLARIFY ROOF SHEATHING THICKNESS. ROOF SHEATHING | | | NOTE ON SHEET A2.0 SPECIFIES 19/32" CDX PLYWOOD ROOF | | | SHEATHING, WHILE, CROSS SECTIONS 1/A5.0 AND 2/A5.0 | | | SPECIFIES 3/4" PLYWOOD SHEATHING. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | 5- ENGINEER OF RECORD TO SPECIFY ON PLANS ROOF | | | VENTILATION AS REQUIRED BY SEC. R806. SPECIFY LOCATION | | | AND SIZE. | | | | | | 6- TRUSS PACKAGE SUBMITTED NEED TO HAVE ENGINEER'S | | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY SEC. | | | 61G15-23.002 FLORIDA ADMINISTRATIVE CODE AND CHAPTER | | | 471 FLORIDA STATUTE. | | | ***NOTE: PROVIDE TRUSS PACKAGE WITH ENGINEER'S SEAL AND | | | SIGNATURE TO THE BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-03-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-26 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-26 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2013-03-26 15:26:02 | RESIDENTIAL (R3) ADDITION BUILDING REVIEW CHECKLIST. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF COVERING. | | | | | | ***NOTE: PLANTATION ROOF TILE NOA 10-0804.15 SUBMITTED | | | WAS SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE | | | WEBSITE AND DOWNLOAD CURRENT NOA. | | | | | | B) SELF-ADHESIVE UNDERLAYMENT FOR NEW CONCRETE ROOF | | | TILE AS SPECIFIED BY THE ENGINEER OF RECORD. | | | | | | ***NOTE: BORAL ROOF UNDERLAYMENTS FL14317-R1 SUBMITTED | | | CAN'T BE USED IN THIS BUILDING. ACCORDING TO SEC. | | | 5.5.2.1 OF THE FLORIDA PRODUCT APPROVAL SUBMITTED THE | | | MAXIMUM DESIGN PRESSURE IS -45PSF. NEED PRODUCT | | | APPROVAL THAT MEETS OR EXCEEDS DESIGN PRESSURES FOR | | | ROOF PERIMETER AND CORNER AREAS. SEE PLANS FOR | | | CALCULATED DESIGN PRESSURES THAT NEED TO BE MET. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL OF THE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | TO FBC. | | | | | | 3- ENGINEER OF RECORD TO PROVIDE COMPLETE ROOF ASSEMBLY | | | SPECIFICATIONS AS REQUIRED BY SEC. 107.2.1.2 CITY | | | AMENDMENTS. SPECIFY ROOF TILE FASTENING METHOD. | | | DRAWINGS SUBMITTED DON'T SPECIFY TILE FASTENING METHOD. | | | | | | 4- CLARIFY ROOF SHEATHING THICKNESS. ROOF SHEATHING | | | NOTE ON SHEET A2.0 SPECIFIES 19/32" CDX PLYWOOD ROOF | | | SHEATHING, WHILE, CROSS SECTIONS 1/A5.0 AND 2/A5.0 | | | SPECIFIES 3/4" PLYWOOD SHEATHING. SEC. 107.2.1 CITY | | | AMENDMENTS TO FBC. | | | | | | 5- ENGINEER OF RECORD TO SPECIFY ON PLANS ROOF | | | VENTILATION AS REQUIRED BY SEC. R806. SPECIFY LOCATION | | | AND SIZE. | | | | | | 6- TRUSS PACKAGE SUBMITTED NEED TO HAVE ENGINEER'S | | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY SEC. | | | 61G15-23.002 FLORIDA ADMINISTRATIVE CODE AND CHAPTER | | | 471 FLORIDA STATUTE. | | | ***NOTE: PROVIDE TRUSS PACKAGE WITH ENGINEER'S SEAL AND | | | SIGNATURE TO THE BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-02-04 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-02-04 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2013-02-04 17:30:02 | RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ACCORDING TO SEC. R301.2.1.4.3 OF 2010 | | | FBC-RESIDENTIAL THIS BUILDING IS LOCATED ON EXPOSURE | | | "D" NOT "B". REVISE DESIGN SPECIFICATIONS AND REVISE | | | ALL THE DESIGN PRESSURES AS REQUIRED. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) ROOF COVERING. (CONCRETE TILE ACCORDING TO PROPERTY | | | APPRAISAL). | | | B) CONCRETE TILE ADHESIVE IF USING IT FOR THE | | | INSTALLATION OF TILE. SEE TILE PRODUCT APPROVAL FOR | | | LISTED PRODUCTS. | | | C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS/DETAILS. ***NOTE; PROVIDE ONLY THE PRODUCT | | | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED | | | CONNECTOR. | | | | | | 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC. | | | | | | 4- ENGINEER OF RECORD TO PROVIDE COMPLETE ROOF ASSEMBLY | | | SPECIFICATIONS AS REQUIRED BY SEC. 107.2.1.2 CITY | | | AMENDMENTS. SPECIFY ROOF TILE FASTENING METHOD AND THE | | | DESIGN PRESSURES. | | | | | | 5- PROVIDE ROOF SHEATHING COMPLETE SPECIFICATIONS. | | | SPECIFY WOOD TYPE, THICKNESS AND FASTENING AS REQUIRED | | | BY SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL. ***NOTE: | | | MIN. 8D RING SHANK NAILS ARE REQUIRED AND CORNER AREAS | | | (4'-0" MIN.) REQUIRE NAILING AT 4"O.C. | | | | | | 6- SPECIFY ON PLANS CARBON MONOXIDE ALARMS AS REQUIRED | | | BY SEC. R315 OF 2010 FBC-RESIDENTIAL. | | | | | | 7- SPECIFY ON PLANS ROOF VENTILATION AS REQUIRED BY | | | SEC. R806. | | | | | | 8- SPECIFY ON PLANS ATTIC ACCESS FOR NEW ROOF AREA AS | | | REQUIRED BY SEC. R807. | | | | | | 9- ENGINEER OF RECORD TO PROVIDE AL THE INFORMATION ON | | | THE DRAWINGS TITLE BLOCK AS REQUIRED BY SEC. | | | 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE AND CHAPTER | | | 471 FLORIDA STATUTE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-03-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-03-22 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-03-22 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-02-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-02-01 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-02-01 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-06-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-06-04 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-05-24 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2013-05-25 11:40:00 | GAVE TO JULIO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-03-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-27 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-27 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2013-03-27 14:51:04 | PRODUCT APPROVALS SUBMITTED BY E-MAIL. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-03-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-03-27 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-03-21 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-02-04 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-01-15 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2013-01-16 14:20:24 | SENT TO R2 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-08-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-15 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-15 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2013-08-15 14:01:31 | NEED ROOFING CONTRACTOR FOR THE ROOFING SUB-PERMIT. | | | PRODUCT APPROVALS ALREADY APPROVED WITH MASTER PERMIT. | | | JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-01-18 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-01-18 |
Time |
|
Rev Time |
|
| Received By |
mdekle |
Date |
2013-01-18 |
Time |
|
Sent To |
|
|
| Notes |
| 2013-01-17 10:55:44 | 1/17/13 |
|
|