| Plan Review Stops For Permit 13010273 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-02-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2013-02-05 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-02-05 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-01-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-22 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-22 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2013-01-22 18:04:54 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A STRUCTURAL DETAIL FOR PROPOSED WORK, FBC | | | 106, FBC R 301. INCLUDE WIND DESIGN CRITERIA (WIND | | | SPEED AND EXPOSURE CLASSIFICATION). | | | | | | 2. THE PRINTED NAME AND SIGNATURE OF THE INDIVIDUAL | | | TAKING RESPONSIBILITY FOR THE DESIGN IS TO BE INCLUDED | | | ON THE PLAN FBC 107. | | | | | | 3. FLOOR PLAN SHOWS THAT THE ENTIRE SPACE, FRONT OF | | | HOUSE TO REAR, IS A SUNROOM. PROVIDE AN ACCURATE FLOOR | | | PLAN. IF A BEDROOM IS AFFECTED, PROVIDE CLEAR OPENING | | | AREA FBC EB 604.1. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-01-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-22 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-14 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2013-01-14 10:03:55 | TO MISC BOX # 1. JW |
|
|
|