Plan Review Details - Permit 13010144
Plan Review Stops For Permit 13010144
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-23 Cont ID  
Sent By jwitmer Date 2013-01-23 Time 12:56 Rev Time 0.00
Received By jwitmer Date 2013-01-23 Time 12:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-10 Cont ID  
Sent By jwitmer Date 2013-01-10 Time 10:28 Rev Time 0.00
Received By jwitmer Date 2013-01-10 Time 10:28 Sent To  
Notes
2013-01-10 10:48:44BUILDING PLAN REVIEW
 PERMIT: 13010144
 ADD: 4920 LORING DRIVE
 CONT: METRO PCS
 TEL: (772)353-7401
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 JAN. 10/2013
 ACTION: DENIED
  
 1) PEASE REVIEW NOTE # 2 FOUND ON SHEET A-1 FOR KHA. A
 CERTIFIFIED LETTER/ REPORT SEALED BY A REGISTERED
 PROFESSIONAL ENGINEER STATING THE SUFFIENT CAPACITY IN
 ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) THE PLANS ARE MISSING THE WIND DESIGN CRITERIA.
 1609.1.1 EXCEPTION # 5 ANSI/ EIA/TIA-222G-05.
  
 OR
  
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 2.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 2.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 2.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 2.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 2.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
 3) SHEET A-1 DOES NOT PROVIDE AT WHAT DISTANCE THE TWO
 BRACKET FASTENER ASSEMBLIES HAVE TO BE APART, NOR DOES
 THE PLAN STATE FOR THAT GIVEN DISTANCE THE FASTENERS
 ARE LOCATED WHAT THE MAXIMUM DISTANCE THE POLE/ MAST
 CAN BE ABOVE THE TOP FASTENER. THIS WILL ALSO NEED TO
 BE ADDRESSED BY THE REGISTERED PROFESSIONAL ENGINEER
 PROVIDING THE LETTER/ REPORT. RESISTING THE FORCES FOR
 THE MOMENT OF OVERTURNING. 2010 FBC-B 1609.8 ROOFTOP
 STRUCTURES AND EQUIPMENT OR 1609.1.1 EXCEPTION # 5
 ANSI/ EIA/TIA-222G-05.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 19

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-01-10 Cont ID  
Sent By rlecky Date 2013-01-10 Time 09:45 Rev Time 0.00
Received By rlecky Date 2013-01-10 Time 09:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-23 Cont ID  
Sent By jwitmer Date 2013-01-23 Time 12:56 Rev Time 0.00
Received By jwitmer Date 2013-01-22 Time 14:51 Sent To  
Notes
2013-01-22 14:51:33SENT TO J WITMER.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-11 Cont ID  
Sent By lmartine Date 2013-01-11 Time 16:59 Rev Time 0.00
Received By lmartine Date 2013-01-07 Time 11:23 Sent To  
Notes
2013-01-08 11:25:08EXPEDITED
 B--12
  

Review Stop Z ZONING
Rev No 1 Status P Date 2013-01-11 Cont ID  
Sent By eschneid Date 2013-01-11 Time 10:49 Rev Time 0.50
Received By eschneid Date 2013-01-11 Time 10:49 Sent To  
Notes
2013-01-11 10:53:26PASSED W/PROVIOS
  
 1) NO LOGOS ARE PERMITTED ON THE MICROWAVE DISHES.
  
 2) THE MICROWAVE DISHES AND ASSOCIATED EQUIPMENT SHALL
 BE PAINTED TO MATCH THE BUILDING.
  