Plan Review Details - Permit 13010059
Plan Review Stops For Permit 13010059
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-03-29 Cont ID  
Sent By rmcdouga Date 2013-03-29 Time 15:48 Rev Time 0.00
Received By rmcdouga Date 2013-03-29 Time 15:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-03-01 Cont ID  
Sent By RMCDOUGA Date 2013-03-01 Time 11:19 Rev Time 0.00
Received By rmcdouga Date 2013-03-01 Time 11:19 Sent To  
Notes
2013-03-01 11:29:472010 FBC
  
 DENIED BY BUILDING
  
 1) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED BY THE OWNER/AGENT. FBC ENERGY 401.2
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-07 Cont ID  
Sent By rmcdouga Date 2013-01-07 Time 16:18 Rev Time 0.00
Received By rmcdouga Date 2013-01-07 Time 16:18 Sent To  
Notes
2013-01-07 16:20:332010 FBC
  
 DENIED BY BUILDING
  
 1) SPECIFY THE DESIGN WIND SPEED FOR THE STRUCTURE ON
 THE PLANS WITH THE DESIGN CRITERIA ON SHEET A-2. FBCR
 301.2.1
  
 2) BASED ON FBCR 301.2.1.4.3 THE STRUCTURE IS LOCATED
 IN EXPOSURE CATEGORY C NOT B. PLEASE REVISE.
  
 3) PROVIDE A FLOOR PLAN OF THE EXISTING STRUCTURE PRIOR
 TO THE REMODEL. CITY AMENDMENTS 107.2.1
  
 4) SPECIFY THE EXISTING AREA CALCULATIONS AND THE
 PROPOSED AREA CALCULATIONS ON THE PLANS. CITY
 AMENDMENTS 107.2.1.3
  
 5) NOTE: THE PLANS WILL BE REQUIRED TO BE REVIEWED BY
 PALM BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE
 DUE.
  
 6) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE ADDED
 LIVING SPACE. FBC ENERGY CONSERVATION 401.2
  
 7) SPECIFY THE HORIZONTAL REINFORCEMENT FOR THE
 CONCRETE BOND BEAM AT THE TOP OF THE STEM WALL. FBCR
 404.1.1.1.1
  
 8) SHOW COMPLIANCE WITH FBCR 806.1 FOR ATTIC
 VENTILATION ON THE PLANS.
  
 9) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW
 EXTERIOR DOORS, WINDOWS, STORM PANELS AS REQUIRED BY
 DCA RULE 9N-3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-03-29 Cont ID  
Sent By rmcdouga Date 2013-03-29 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2013-03-29 Time 15:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-01-07 Cont ID  
Sent By rmcdouga Date 2013-01-07 Time 16:18 Rev Time 0.00
Received By rmcdouga Date 2013-01-07 Time 16:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-03-29 Cont ID  
Sent By rmcdouga Date 2013-03-29 Time 15:51 Rev Time 0.00
Received By rmcdouga Date 2013-03-28 Time 15:49 Sent To  
Notes
2013-03-28 16:36:56SENT TO MCDOUGAL'S DESK FOR REVIEW/PROCESSING. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-03-01 Cont ID  
Sent By rmcdouga Date 2013-03-01 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2013-02-01 Time 09:43 Sent To  
Notes
2013-02-04 09:44:00R25

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-02-04 Cont ID  
Sent By rmcdouga Date 2013-02-04 Time 09:44 Rev Time 0.00
Received By rmcdouga Date 2013-01-31 Time 17:35 Sent To  
Notes
2013-02-04 09:44:35R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-08 Cont ID  
Sent By mdekle Date 2013-01-08 Time   Rev Time 0.00
Received By mdekle Date 2013-01-03 Time 16:01 Sent To  
Notes
2013-01-03 16:03:19R01

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2013-04-01 Cont ID  
Sent By rmcdouga Date 2013-04-01 Time 14:49 Rev Time 0.00
Received By rmcdouga Date 2013-04-01 Time 14:49 Sent To  
Notes
2013-04-01 14:49:54NO IMPACT FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2013-03-29 Cont ID  
Sent By rmcdouga Date 2013-03-29 Time 15:49 Rev Time 0.00
Received By rmcdouga Date 2013-03-29 Time 15:49 Sent To  
Notes
2013-03-29 15:51:53PLANS WERE REVISED. EXISTING CARPORT IS TO REMAIN AS
 CARPORT. NEW PLANS AND VOIDED SET WITH IMPACT FEE STAMP
 NEED TO BE TAKEN TO PALM BEACH COUNTY FOR REFUND.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-02-25 Cont ID  
Sent By rmcdouga Date 2013-02-25 Time 09:49 Rev Time 0.00
Received By rmcdouga Date 2013-02-25 Time 09:49 Sent To  
Notes
2013-02-25 09:49:47MU2013-2319

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-01-07 Cont ID  
Sent By rmcdouga Date 2013-01-07 Time 11:08 Rev Time 0.00
Received By rmcdouga Date 2013-01-07 Time 11:08 Sent To  
Notes
2013-01-07 11:09:50IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-01-07 Cont ID  
Sent By rmcdouga Date 2013-01-07 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2013-01-07 Time 11:28 Sent To  
Notes
2013-01-07 11:29:49NO MECHANICAL PLANS SUBMITTED. SEPARATE PERMIT,
 APPLICATION AND REVIEW IS REQUIRED FOR MECHANICAL.

Review Stop P PLUMBING
Rev No 3 Status P Date 2013-03-29 Cont ID  
Sent By rmcdouga Date 2013-03-29 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2013-03-29 Time 15:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-03-01 Cont ID  
Sent By rmcdouga Date 2013-03-01 Time 11:19 Rev Time 0.00
Received By rmcdouga Date 2013-03-01 Time 11:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-01-07 Cont ID  
Sent By rmcdouga Date 2013-01-07 Time 11:08 Rev Time 0.00
Received By rmcdouga Date 2013-01-07 Time 11:08 Sent To  
Notes
2013-01-07 14:41:132010 FBC
  
 DENIED BY PLUMBING
  
 1) NOT MORE THAN 0NE WET VENTED FIXTURE DRAIN SHALL
 DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE DRAIN
 CONNECTION PER FBCR P3108.2.1 AND FBCR P3108.1 REQUIRES
 EACH WET VENTED FIXTURE DRAIN TO CONNECT INDEPENDENTLY
 TO THE HORIZONTAL WET VENT. SEE TUB AND WATER CLOSET AT
 MASTER BATH.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2013-03-28 Cont ID  
Sent By mdekle Date 2013-03-28 Time   Rev Time 0.00
Received By mdekle Date 2013-03-28 Time   Sent To  
Notes
2013-03-28 15:42:47ZONING:** PASSED W/PROVISO **
 THE PARAMETERS OF WORK SHALL ONLY CONSIST OF
 ENCLOSING THE EXISTING PORCH.
 THE EXISTING CARPORT SHALL NOT BE ENCLOSED.
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2013-02-07 Cont ID  
Sent By mdekle Date 2013-02-07 Time   Rev Time 0.00
Received By mdekle Date 2013-02-07 Time   Sent To  
Notes
2013-02-07 10:36:46PLANNING: **** FAILED ****
  
 1. THE SUVEY PROVIDED WITH THE SECOND SUBMITTAL
 INDICATES THAT, THE PROPOSED WORK WILL REQUIRE A
 VARIANCE FOR BUILDING SETBACKS. THE SIDE SETBACKS FOR
 BOTH SIDES MUST TOTAL FIFTEEN FEET.
 2. IN ACCORDANCE WITH SECTION SEC. 94-482. - PARKING
 REQUIREMENTS FOR LESS THAN THREE RESIDENTIAL DWELLING
 UNITS, THE APPLICANT MUST PROVIDE LANDSCAPING WITHIN
 THE FRONT YARD.
  
 (A)LOCATION AND SURFACE. REQUIRED OFF-STREET PARKING
 SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING UNITS
 SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE UNITS
 ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A FRONT
 YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75
 PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH
 LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND COVER,
 SHRUBS, HEDGES, VINES OR TREES).
  
 THE REVISED SITE PLAN DEPICTS PAVER STONE WITHIN THE
 MAJORITY OF THE FRONT YARD. PLEASE REVISE AND PROVIDE
 CALCULATIONS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY'S ZONING AND LANDDEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2013-01-08 Cont ID  
Sent By mdekle Date 2013-01-08 Time   Rev Time 0.00
Received By mdekle Date 2013-01-08 Time 10:15 Sent To  
Notes
2013-01-08 10:16:051. IN ACCORDANCE WITH SECTION 94-82, THE RESIDENTIAL
 UNIT SHALL PROVIDE OFF STREET PARKING ON THE PROPERTY
 ON WHICH THE UNITS ARE LOCATED. THE ELIMINATION OF THE
 ?CARPORT? AREA MAY NOT ALLOW FOR ADEQUATE CAR PARKING
 ONSITE. PLEASE PROVIDE AN EXPLANATION/PLAN FOR CAR
 PARKING.
 2. THE STEPS ASSOCIATED WITH THE FRONT PROPOSED FRONT
 PORCH APPEAR TO POTENTIALLY ENCROACH INTO THE FRONT
 YARD SETBACK (25?). PLEASE INCLUDE THESE PROPOSED
 IMPROVEMENTS ON THE SURVEY.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME
 AND/OR CONSULT THE CITY?S ZONING AND LAND
 DEVELOPMENT REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA, PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  