| Plan Review Stops For Permit 13010051 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-01-24 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-01-23 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-01-08 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-01-08 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2013-01-08 16:30:53 | BUILDING PLAN REVIEW | | | PERMIT: 13010051 | | | ADD: 771 VILLAGE BLVD # 206 | | | CONT: L C CONSTRUCTION MANAGEMENT | | | TEL: (786)436-7062 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | JAN. 08/2013 | | | ACTION: DENIED | | | | | | 1) THE NEW HANDICAPPED RESTROOM DOES NOT MEET THE ROOM | | | REQUIREMENTS OF THE 2010 FL ACCESSIBILITY CODE SEE | | | FIGURE 604.1.8.6 AND THE CLEAR FLOOR SPACE REQUIRED FOR | | | THE WATER CLOSET UNDER 2010 FL ACCESSIBILTY CODE | | | SECTION 604.3.2 . | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-01-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-01-24 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-24 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2013-01-16 14:30:50 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-01-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-01-08 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-08 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2013-01-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-22 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-01-22 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2013-01-16 14:32:29 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-01-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-05 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-01-05 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-01-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-01-24 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-15 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2013-01-16 14:29:10 | SENT TO B5 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-01-10 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-01-10 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-01-03 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-01-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2013-01-22 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2013-01-22 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2013-01-22 11:50:25 | *** PROVISO *** | | | 1) COMPLY WITH 2010 FBC/ENERGY 503.2.4.4 SHUTOFF DAMPER | | | CONTROLS. BOTH OUTDOOR AIR SUPPLY AND EXHAUST DUCTS | | | SHALL BE EQUIPPED WITH DAMPERS THAT WILL AUTOMATICALLY | | | SHUT WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE. | | | 2) REVISE MECH. PLAN M-1 TO SHOW CORRECT RETURN AIR | | | DUCT SIZES BEFORE ROUGH INSPECTION, PER 2010 CITY OF | | | WPB AMEND. 107.3.5.1.4 (6) AND 2010 FBC/M 601.4. | | | MECHANICAL PLAN REVIEW BY: | | | TOM GORDON (HY-BYRD INC.) (561) 805-6732 | | | | | 2013-01-16 14:31:49 | NEW SHEETS SUBMITTED. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-01-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2013-01-08 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2013-01-08 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2013-01-08 09:58:54 | *** PROVISO *** | | | 1) COMPLY WITH 2010 FBC/ENERGY 503.2.4.4 SHUTOFF DAMPER | | | CONTROLS. BOTH OUTDOOR AIR SUPPLY AND EXHAUST DUCTS | | | SHALL BE EQUIPPED WITH DAMPERS THAT WILL AUTOMATICALLY | | | SHUT WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE. | | | 2) REVISE MECH. PLAN M-1 TO SHOW CORRECT RETURN AIR | | | DUCT SIZES BEFORE ROUGH INSPECTION, PER 2010 CITY OF | | | WPB AMEND. 107.3.5.1.4 (6) AND 2010 FBC/M 601.4. | | | MECHANICAL PLAN REVIEW BY: | | | TOM GORDON (HY-BYRD INC.) (561) 805-6732 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-01-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-01-17 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-01-17 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-01-10 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-01-10 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-01-04 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2013-01-09 14:39:58 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. THE RESTROOM WILL BE REQUIRED TO BE A MINIMUM OF | | | 7'-1" WIDE TO ACHIEVE THE REQUIRED 60" CLEAR SPACE FOR | | | THE WATER CLOSET. (OTHER CONFIGURATIONS ARE ALSO | | | POSSIBLE). | | | FBC ACCESSIBILITY CODE 2010 604.3.1 SIZE. CLEARANCE | | | AROUND A WATER CLOSET SHALL BE 60 INCHES (1525 MM) | | | MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND | | | 56 INCHES (1420 MM) MINIMUM MEASURED PERPENDICULAR FROM | | | THE REAR WALL. | | | FBC ACCESSIBILITY CODE 2010 604.3.2 THE LAVATORY WILL | | | NOT BE PERMITTED IN THE 60" SPACE. | | | PLEASE SEE FIGURE 604.8.1.6 ALSO. | | | | | | 2. IF A DRINKING FOUNTAIN IS PROVIDED IN THIS | | | OCCUPANCY, IT WILL BE REQUIRED TO BE A HI/LO TYPE. | | | | | | FBC ACCESSIBILITY 2010 211.1 GENERAL. WHERE DRINKING | | | FOUNTAINS ARE PROVIDED ON AN EXTERIOR SITE, ON A FLOOR, | | | OR WITHIN A SECURED AREA THEY SHALL BE PROVIDED IN | | | ACCORDANCE WITH 211. | | | FBC ACCESSIBILITY 2010 211.2 MINIMUM NUMBER. NO FEWER | | | THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE | | | DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6 | | | AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. | | | EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES | | | WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE | | | PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING | | | FOUNTAINS. | | | | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2013-01-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-01-07 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-01-07 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|