Plan Review Details - Permit 12120776
| Plan Review Stops For Permit 12120776 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2013-01-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-29 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-29 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2013-01-29 13:36:22 | SEE MASTER | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-28 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-28 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2013-01-28 16:30:59 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | FBC R 301, RESISTANCE TO WIND LOADS: | | | | | | 1. OK | | | | | | 2. INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED. | | | | | | 2ND REVIEW, THE ASSEMBLY ON SHEET 21 HIGHLIGHTED. IF | | | YOU USE THIS ASSEMBLY, ENHANCED FASTENING CALCULATIONS | | | REQUIRED. PLEASE NOTE THAT THE ASSEMBLY ON SHEET 23 | | | COMPLIES WITH DESIGN PRESSURE FOR ZONE 3 AND ENHANCED | | | FASTENING SPECIFIED BY AN ARCHITECT OR ENGINEER WOULD | | | NOT THEN BE REQUIRED. | | | | | | 3. ENHANCED FASTENING NAILING IS TO STATE NUMBER OF | | | FIELD ROWS. | | | | | | 2ND REVIEW, ENHANCED FASTENING CALCULATIONS NOT | | | SUBMITTED. | | | | | | 4. OK | | | | | | NEW COMMENT: | | | | | | PER BUILDING OFFICIAL, THIS IS NOT A SUB PERMIT, THIS | | | SHOULD BE A REVISION TO THE MASTER AND THEN A SUB | | | PERMIT CAN BE ISSUED AFTER REVISION HAS BEEN REVIEWED | | | AND PASSED. THIS COMMENT DOES NOT NEED TO BE ADDRESSED | | | BUT ADJUSTMENTS TO FEES SHALL BE MADE PRIOR TO | | | ISSUANCE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-02 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-02 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2013-01-02 15:02:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FBC R 301, RESISTANCE TO WIND LOADS: | | | | | | 1. PLEASE SEE DEFINITION OF EXPOSURE B, FBC RESIDENTIAL | | | 301, ASCE7-10. THIS PARCEL IS LOCATED IN EXPOSURE C. | | | THE ARCHITECT STATES THAT THE PROPERTY IS MORE THAN ONE | | | MILE FROM THE INTRACOASTAL; THIS CONDITION DOES NOT | | | DETERMINE EXPOSURE B. | | | | | | 2. INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED. | | | | | | 3. ENHANCED FASTENING NAILING IS TO STATE NUMBER OF | | | FIELD ROWS. | | | | | | 4. NOA SUBMITTED IS NOT LEGIBLE. PROVIDE TWO LEGIBLE | | | SETS OF DOCUMENTS FBC 107. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-28 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-17 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2013-01-17 11:17:15 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-02 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-28 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2012-12-28 16:39:42 | GAVE TO SAMANTHA |
|
|
|