Plan Review Details - Permit 12120605
Plan Review Stops For Permit 12120605
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-02-07 Cont ID  
Sent By jwitmer Date 2013-02-07 Time 09:42 Rev Time 0.00
Received By jwitmer Date 2013-02-07 Time 09:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-01-02 Cont ID  
Sent By jwitmer Date 2013-01-02 Time 14:44 Rev Time 0.00
Received By jwitmer Date 2013-01-02 Time 11:35 Sent To  
Notes
2013-01-02 14:55:39BUILDING PLAN REVIEW
 PERMIT: 12120605
 ADD: 1685 FORUM PLACE
 CONT: INFINIMAGE CONSTRUCTION
 TEL: (407)808-8849
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 JAN. 02/2013
 ACTION: DENIED
  
 1) SHEET A1 THE LIFE SAFETY PLAN DOES NOT SHOW BATTERY
 BACK UP EMERGENCY LIGHTING AT THE BACK OF THE SHOP.
 2010 FBC-B 1006.1.6.2
 BATTERY-OPERATED ELECTRIC LIGHTS AND OTHER TYPES OF
 PORTABLE LAMPS OR LANTERNS SHALL NOT BE USED FOR
 PRIMARY ILLUMINATION OF MEANS OF EGRESS.
 BATTERY-OPERATED ELECTRIC LIGHTS SHALL BE PERMITTED TO
 BE USED AS AN EMERGENCY SOURCE TO THE EXTENT PERMITTED
 UNDER SECTION 1006.2.3.4.
  
 1006.1.4
 REQUIRED ILLUMINATION SHALL BE ARRANGED SO THAT THE
 FAILURE OF ANY SINGLE LIGHTING UNIT WILL NOT RESULT IN
 AN ILLUMINATION LEVEL IN ANY DESIGNATED AREA OF LESS
 THAN 0.2 FOOTCANDLE (2 LUX).
  
 1006.2.3.4
 BATTERY-OPERATED EMERGENCY LIGHTS SHALL USE ONLY
 RELIABLE TYPES OF RECHARGEABLE BATTERIES PROVIDED WITH
 SUITABLE FACILITIES FOR MAINTAINING THEM IN A PROPERLY
 CHARGED CONDITION. BATTERIES USED IN SUCH LIGHTS OR
 UNITS SHALL BE APPROVED FOR THEIR INTENDED USE AND
 SHALL COMPLY WITH CHAPTER 27 OF THE FLORIDA BUILDING
 CODE, BUILDING.
  
 2) 713.6
 FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE
 BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
 REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
 EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY
 HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: ?FIRE
 AND SMOKE BARRIER ? PROTECT ALL OPENINGS.?
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-12-28 Cont ID  
Sent By rlecky Date 2012-12-28 Time 16:50 Rev Time 0.00
Received By rlecky Date 2012-12-28 Time 16:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-01-05 Cont ID  
Sent By wjolin Date 2013-01-05 Time 10:24 Rev Time 0.00
Received By wjolin Date 2013-01-05 Time 10:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-02-07 Cont ID  
Sent By jwitmer Date 2013-02-07 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2013-01-23 Time 15:52 Sent To  
Notes
2013-01-28 15:53:02SENT TO B3 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-05 Cont ID  
Sent By wjolin Date 2013-01-05 Time 10:25 Rev Time 0.00
Received By wjolin Date 2012-12-19 Time 12:57 Sent To  
Notes
2012-12-20 09:00:33B04

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-01-31 Cont ID  
Sent By hmoser Date 2013-01-31 Time 09:38 Rev Time 0.00
Received By hmoser Date 2013-01-31 Time 09:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-12-26 Cont ID  
Sent By tgordon Date 2012-12-26 Time 16:11 Rev Time 0.00
Received By tgordon Date 2012-12-26 Time 16:11 Sent To  
Notes
2012-12-26 16:12:14*** MECHANICAL CORRECTIONS NEED ***
  
 1) CEILING HEIGHT IS TOO HIGH FOR THE EXHAUST VENTS.
 SEE 2010 FBC/M TABLE 403.3 NOTE (H). FOR NAIL SALONS,
 THE REQUIRED EXHAUST SHALL INCLUDE VENTILATION TABLES
 OR OTHER SYSTEMS THAT CAPTURE THE CONTAMINANTS AND
 ODORS AT THEIR SOURCE AND ARE CAPABLE OF EXHAUSTING A
 MINIMUM OF 50 CFM PER STATION.
  
 2) PLAN M-1 OUTSIDE AIR 500 CFM'S APPEAR TO BE TO LOW,
 SEE ASHRAE STANDARD 62.1-2007, 6.2.2.1 & TABLE 6-1 FOR
 MORE DETAILED INFORMATION REGARDING OUTDOOR AIR
 CALCULATIONS, OR FBC/M 403.3. PLEASE SHOW OUTDOOR AIR
 CALCULATIONS ON MECHANICAL PLAN.
  
 3) PLAN M-1 MECHANICAL VENTILATION CALCULATIONS SHOWS,
 EXHAUST FOR NAIL STATIONS 50 CFM'S PER NAIL STATION.
 THIS IS THE MINIMUM, SEE 2010 FBC/M TABLE 403.3 EXHAUST
 AIRFLOW COLUMN (0.6 CFM'S PER SQUARE FOOT). PLEASE
 CORRECT.
  
 4) PLAN M-1 AIR BALANCE SUMMARY, SHOWS THE BUILDING AT
 0 PRESSURE. PER 2010 FBC/ENERGY 503.2.10.6 BUILDING
 PRESSURES. MECHANICAL SYSTEMS SHALL BE DESIGNED TO
 ASSURE THAT BUILDINGS ARE PRESSURIZED WITH RESPECT TO
 OUTDOORS.
  
 MECHANICAL PLAN REVIEW BY:
 TOM GORDON (HY-BYRD INC.) (561) 805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-01-02 Cont ID  
Sent By lwagner Date 2013-01-02 Time 10:21 Rev Time 0.00
Received By lwagner Date 2013-01-02 Time 09:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2013-01-03 Cont ID  
Sent By ajones Date 2012-12-28 Time 09:26 Rev Time 0.00
Received By ajones Date 2012-12-28 Time 09:26 Sent To  
Notes
2012-12-28 09:29:50NO BARS ALLOWED