| Plan Review Stops For Permit 12120434 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-05-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-05-02 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-05-02 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2013-05-02 10:59:42 | BUILDING PROVISO: | | | 2010 FBC-B 1816.1.4 | | | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE | | | PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED | | | WITH A MINIMUM 6 MILLIMETER VAPOR RETARDER TO PROTECT | | | AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE | | | VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. ANY | | | WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE | | | AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS | | | POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID | | | PENETRATING OR DISTURBING TREATED SOIL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-12-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-27 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-26 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2012-12-27 10:39:56 | BUILDING PROVISO: | | | 2010 FBC-B 1816.1.4 | | | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE | | | PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED | | | WITH A MINIMUM 6 MILLIMETER VAPOR RETARDER TO PROTECT | | | AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE | | | VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. ANY | | | WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE | | | AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS | | | POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID | | | PENETRATING OR DISTURBING TREATED SOIL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-05-13 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-05-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-05-13 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-12-31 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-12-31 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-12-31 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2012-12-31 16:14:10 | 12120434 | | | 1921 SOUTH DIXIE HIGHWAY | | | COMMERCIAL RENOVATION | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENT. | | | | | | VERIFY THE NEW AND EXISTING SERVICE EQUIPMENT IS | | | SUFFICIENT TO HANDLE THE AVAILABLE FAULT CURRENT. NEC | | | 110.9 | | | | | | PROVIDE DEDICATED 20 AMPERE BRANCH CIRCUIT (S) FOR | | | SIGNAGE. NEC 600.5 | | | | | | GFCI PROTECTION IS REQUIRED FOR WATER COOLERS. NEC | | | 422.52 | | | | | | THE GENERATOR REQUIRES A SEPARATE PERMIT WITH PLANS AND | | | SPECIFICATIONS. PLEASE INCLUDE CONDUIT SUPPORT AND | | | FLASHING DETAIL FOR ALL CONDUIT AND EQUIPMENT. INCLUDE | | | ENGINEERING FOR THE SUPPORT AND ANCHORAGE OF THE | | | GENERATOR. FBC 105.1 | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2013-05-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-05-06 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-05-04 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-12-19 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-12-19 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2012-12-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-12-17 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-12-17 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2013-05-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-05-10 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-05-10 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2013-05-10 17:04:11 | NO HISTORIC REVIEW REQUIRED (INTERIOR AND MECHANICAL | | | WORK ONLY). | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT (561) 822-1448. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-05-16 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-04-23 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-12-31 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-12-31 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-12-13 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-05-16 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-05-16 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2013-05-16 14:54:49 | SEPARATE PERMIT REQUIRED FOR GENERATOR | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2012-12-19 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2012-12-19 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2012-12-19 14:21:56 | NOTE: THE GENERATOR WILL REQUIRE IT'S OWN PERMIT. | | | SUBMIT PLANS, ENGINEERING, AND DETAILED MANUFACTURER'S | | | SPECIFICATION'S WHEN APPLYING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-04-26 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-04-26 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-04-26 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-12-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-12-17 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-12-17 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2012-12-17 14:40:37 | ***PROVISO*** | | | FBC PLUMBING 314.2.1 CONDENSATE DISPOSAL. | | | ...CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY | | | OR OTHER AREAS SO AS TO CAUSE A NUISANCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-05-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2013-05-10 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2013-05-06 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-12-21 |
|
|
Cont ID |
|
| Sent By |
fmitter |
Date |
2012-12-21 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-12-21 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2012-12-21 16:47:13 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 12.21.2012 | | | PERMIT NO.: 12120434 | | | ADDRESS: 1921 SOUTH DIXIE HIGHWAY | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: 561.436.3370 | | | SCOPE OF REVIEW: NEW CONCRETE FLOOR, NEW ELECTRIC, A/C | | | AND HVAC. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLANS INDICATE THE ADDITION OF A/C MECHANICAL | | | EQUIPMENT, AS WELL AS A GENERATOR, ON TOP OF THE | | | EXISTING ROOF. PLEASE PROVIDE ADDITIONAL INFORMATION, | | | SECTIONS, DETAILS, ETC. TO ENSURE THAT THE EQUIPMENT IS | | | NOT VISIBLE FROM SURROUNDING PROPERTIES AND/OR THE | | | PUBLIC RIGHT-OF-WAY. IT IS UNCLEAR AS TO THE SIZE OF | | | THE EQUIPMENT, HEIGHT UPON WHICH IS MOUNTED ABOVE THE | | | ROOF, ETC. | | | | | | 2. THE PLANS SHOW ?EXISTING? TILE ROOFING ALONG THE | | | EAST AND SOUTH PARAPETS, HOWEVER, AERIAL PHOTOS OF THE | | | PROPERTY DO NOT SHOW THIS. PLEASE EXPLAIN. IS THIS WORK | | | PART OF THE SCOPE OF THE RENOVATIONS? | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | | | 2012-12-18 17:22:37 | 12/18/12 |
|
|