| 2012-12-13 13:04:00 | BUILDING PLAN REVIEW |
| | PERMIT: 12120395 |
| | ADD: 1500 N DIXIE HWY SUITE # 100 |
| | CONT: THOMAS ROGERS INC |
| | TEL: (561)324-6944 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DEC. 13/2012 |
| | ACTION: DENIED |
| | |
| | 1) THIS WILL BE CONSIDERED A PHASED PERMIT. THE |
| | BUILDING PERMIT WILL NOT BE ISSUED UNTIL THE MEP TRADES |
| | HAVE MADE APPLICATION FO PREMIT, AT THAT TIME IF ALL |
| | OTHER REQUIREMENTS ARE MET THE BUILDING PERMIT WILL BE |
| | ISSUED. |
| | |
| | 2) THIS IS A COMMERCIAL CONDOMINIUM, PLEASE PROVIDE THE |
| | WHOLE FLOOR PLAN OF THIS FLOOR TO SEE WHAT WALLS |
| | REQUIRE FIRE RATED WALLS, TENANT SEPERATION WALLS, |
| | CORRIDOR WALLS, IS THE FIRST FLOOR CEILING BEING |
| | REMOVED, THIS WOULD BE A ONE HOUR RATED FLOOR / CEILING |
| | ASSEMBLY, IF THIS BUILDING IS FIRE SPRINKLERED OR NOT? |
| | 2010 FBC- ADMINISTRATIVE CODE 107.3.5.1.1. MINIMUM |
| | CRITERIA FOR COMMERCIAL PLAN REVIEW |
| | |
| | 1006.3 EXIT SIGNS. 1006.3.1 |
| | EXITS SHALL BE MARKED BY AN APPROVED SIGN READILY |
| | VISIBLE FROM ANY DIRECTION OF EXIT ACCESS. EVERY EXIT |
| | SIGN SHALL BE SUITABLY ILLUMINATED BY A RELIABLE LIGHT |
| | SOURCE. EXTERNALLY AND INTERNALLY ILLUMINATED SIGNS |
| | SHALL BE VISIBLE IN BOTH NORMAL AND EMERGENCY LIGHTING. |
| | |
| | |
| | . PLEASE NOTE THE NOTE FOR WALL TYPES ARE NOT LEGABLE |
| | AND FOR RECORD RETENSION, (SCANNING) WILL NOT SHOW UP, |
| | THEY WILL NEED TO BE BETTER IDENTIED, BOLDER, BLACK |
| | INK. 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING |
| | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND |
| | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS |
| | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH |
| | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR |
| | OTHER ITEMS RELATED TO RECORDS |
| | MANAGEMENT. |
| | |
| | 3) THE DESIGNER OF RECORD SHALL SIGN AND PRINT THEIR |
| | NAME AND LICENSE NUMBER ON THE PLANS, 107.3.4.3 |
| | CERTIFICATIONS BY CONTRACTORS AUTHORIZED UNDER THE |
| | PROVISIONS OF SECTION 489.115 FLORIDA STATUTES, SHALL |
| | BE CONSIDERED EQUIVALENT TO SEALED PLANS AND |
| | SPECIFICATIONS BY A PERSON LICENSED UNDER CHAPTER 471, |
| | FLORIDA STATUTES, OR CHAPTER 481 FLORIDA STATUTES, BY |
| | LOCAL ENFORCEMENT AGENCIES ... |
| | |
| | 4) THE DESIGNER OF RECORD, SHALL SELECT A COMPLIANCE |
| | METHOD UNDER THE 2010 FBC-EXISSTING BUILDING CODE, |
| | 101.5 COMPLIANCE METHODS. |
| | |
| | 5) 2010 FBC-ACCESSIBILITY CODE. 202.4.1 |
| | DISPROPORTIONATE COST. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20% OF THE |
| | |
| | COST OF THE ALTERATION TO THE PRIMARY FUNCTION AREA. |
| | COSTS THAT MAY BE COUNTED AS EXPENDITURES REQUIRED TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) |
| | COSTS ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE |
| | AND AN ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS |
| | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS |
| | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, |
| | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET |
| | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING |
| | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE |
| | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION |
| | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) |
| | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE |
| | DRINKING FOUNTAIN. |
| | |
| | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| | DISPROPORTIONALITY. |
| | WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| | OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| | DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| | ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| | ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| | FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| | ALARMS. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |