Plan Review Details - Permit 12120213
Plan Review Stops For Permit 12120213
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-15 Cont ID  
Sent By jwitmer Date 2013-01-15 Time 10:44 Rev Time 0.00
Received By jwitmer Date 2013-01-15 Time 10:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-14 Cont ID  
Sent By jwitmer Date 2012-12-13 Time 10:29 Rev Time 0.00
Received By jwitmer Date 2012-12-13 Time 16:47 Sent To  
Notes
2012-12-13 16:55:04BUILDING PLAN REVIEW
 PERMIT: 12120213
 ADD: 1701 S FLAGLER DR SUITE # 906
 CONT: MAKI CONSTRUCTION
 TEL: (561)602-3852
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DEC. 13/2012
 ACTION: DENIED
  
 1) SHEET 1.1 NOTE # 6 INDICATES THTE REMOVAL OF THE
 EXISTING FLOOR FINISH THROUGH OUT THE WHOLE SUITE AND
 THE INSTALATION OF CORK SOUND FLOOR INSULATION. PLEASE
 PROVIDE
 THE FOLLOWING DOCUMENTATION INDICATING CODE COMPLIANCE.
 1A) 2010 FBC 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE
 STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS (IIC)
 RATING OF NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN
 TESTED IN ACCORDANCE WITH ASTM E 492.
 1B) 2010 FBC- SECTION 603 COMBUSTIBLE MATERIAL IN TYPE
 I AND II CONSTRUCTION. 2 EXCEPTION 1. INSULATION PLACED
 BETWEEN TWO LAYERS OF
 NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING
 AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX
 OF NOT MORE THAN 100.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
 12/18/12 CONTRACTOR E-MAILED PRODUCT SPECS FOR WHISPER
 MAT FLOOR SOUND INSULATION, NOTE THIS IS A FOAM BASED
 INSULATION NOT THE CORK INSULATION SPECED BY THE
 DESIGNER OF RECORD, WILL NEED THE APPROVAL FROM THE
 DESIGNER OFRECORD FOR USE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-12-28 Cont ID  
Sent By rlecky Date 2012-12-28 Time 08:12 Rev Time 0.00
Received By rlecky Date 2012-12-27 Time 15:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-12-17 Cont ID  
Sent By wjolin Date 2012-12-17 Time 11:50 Rev Time 0.00
Received By wjolin Date 2012-12-17 Time 11:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-12-28 Cont ID  
Sent By rlecky Date 2012-12-28 Time 08:12 Rev Time 0.00
Received By rlecky Date 2012-12-07 Time 10:50 Sent To  
Notes
2012-12-13 10:51:17SENT TO B16 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-12-17 Cont ID  
Sent By lmartine Date 2012-12-17 Time 09:05 Rev Time 0.00
Received By lmartine Date 2012-12-17 Time 09:05 Sent To  
Notes
2012-12-17 09:14:07*** PROVISO ***
 1) MASTER SUITE RETURN AIR DUCT MAY NEED TO BE
 ENLARGED. SEE 2010 FBC/RES. M1602.4 BALANCED RETURN
 AIR.
 PROVISIONS SHALL BE MADE IN BOTH RESIDENTIAL AND
 COMMERCIAL BUILDINGS TO AVOID UNBALANCED AIR FLOWS AND
 PRESSURE DIFFERENTIALS CAUSED BY RESTRICTED RETURN AIR.
 PRESSURE DIFFERENTIALS ACROSS CLOSED DOORS WHERE
 RETURNS ARE CENTRALLY LOCATED SHALL BE LIMITED TO 0.01
 INCH WC (2.5 PASCALS) OR LESS. (3) HABITABLE ROOMS ONLY
 SHALL BE REQUIRED TO MEET THESE REQUIREMENTS FOR PROPER
 BALANCED RETURN AIR EXCLUDING BATHROOMS, CLOSETS,
 STORAGE ROOMS AND LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE INCLUDED.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-12-14 Cont ID  
Sent By lwagner Date 2012-12-14 Time 10:47 Rev Time 0.00
Received By lwagner Date 2012-12-14 Time 10:40 Sent To  
Notes
***NONE***