Plan Review Details - Permit 12120095
Plan Review Stops For Permit 12120095
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-07-02 Cont ID  
Sent By jwitmer Date 2013-07-02 Time 17:19 Rev Time 0.00
Received By jwitmer Date 2013-07-02 Time 14:57 Sent To  
Notes
2013-07-02 17:19:30MISSING DOOR PRODUCT APPROVAL, I SPOKE WITH SPENCER
 SCHROEDER PE AND WE FOUND THE CHEM-PRUF MODEL DOOR +/-
 75 PSF.
 PRINTED OUT THE FLORIDA PRODUCT APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-11 Cont ID  
Sent By jwitmer Date 2012-12-11 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2012-12-11 Time 07:29 Sent To  
Notes
2012-12-11 07:48:27BUILDING PLAN REVIEW
 PERMIT: 12120095
 ADD: 4375 EAILEY DR
 CONT: TBD
 CONTACT: DANIEL
 TEL: (561)835-7429
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DEC. 11/ 2012
 ACTION: DENIED
  
 1) THE PLANS, C3-1 NOR C3-2 BOTH INDICATE PRESSURES FOR
 THE NEW COMPONENTS AND CLADDING, WALL LOUVERS AND MAN
 SWING DOOR BUT THE PLANS DO NOT PROVIDE THE
 WIND DESIGN CRITERIA:
 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 1.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 1.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 1.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE
 TABLE 1609.2(2) .
  
  
 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOOR- INSWING.
 (C) WALL LOUVERS,
  
 4) SHEET C1-3 FLOOR PLAN DOES NOT PROVIDE WHERE THE
 LOCATIONS OF THE PORTABLE FIRE EXTINGSUISHERS 2010
 FBC-B 906.1.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-12-28 Cont ID  
Sent By rlecky Date 2012-12-28 Time 16:08 Rev Time 0.00
Received By rlecky Date 2012-12-28 Time 15:01 Sent To  
Notes
2013-01-07 08:35:35TO MECHANICAL

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2012-12-14 Cont ID  
Sent By wjolin Date 2012-12-14 Time 13:01 Rev Time 0.00
Received By wjolin Date 2012-12-14 Time 13:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-07-02 Cont ID  
Sent By jwitmer Date 2013-07-02 Time 17:19 Rev Time 0.00
Received By jwitmer Date 2013-06-17 Time 11:26 Sent To  
Notes
2013-06-18 11:27:18SENT TO JIM'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-15 Cont ID  
Sent By rlecky Date 2013-01-07 Time 14:43 Rev Time 0.00
Received By lmartine Date 2012-12-04 Time 08:58 Sent To  
Notes
2012-12-05 08:58:29C20

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-01-07 Cont ID  
Sent By tgordon Date 2013-01-07 Time 09:28 Rev Time 0.00
Received By tgordon Date 2013-01-07 Time 09:28 Sent To  
Notes
2013-01-07 09:37:24*** PROVISO ***
  
 1) MUFFLER EXHAUST PIPE MUST TERMINATE 10 FT. FROM
 LOUVERED DAMPER, PER 2010 FBC/M 501.2.1 LOCATION OF
 EXHAUST OUTLETS. THE TERMINATION POINT OF EXHAUST
 OUTLETS AND DUCTS DISCHARGING TO THE OUTDOORS SHALL BE
 LOCATED WITH THE FOLLOWING MINIMUM DISTANCES:
 (2) FOR OTHER PRODUCT-CONVEYING OUTLETS: 10 FEET (3048
 MM) FROM THE PROPERTY LINES; 3 FEET (914 MM) FROM
 EXTERIOR WALLS AND ROOFS; 10 FEET (3048 MM) FROM
 OPERABLE OPENINGS INTO BUILDINGS; 10 FEET (3048 MM)
 ABOVE ADJOINING GRADE.
  
 2) PROVIDE REQUIRED PRODUCT APPROVAL FOR LOUVERED
 DAMPERS AS REQUESTED IN BUILDING REVIEW.
  
 MECHANICAL PLAN REVIEW BY:
 TOM GORDON (HY-BYRD INC.) (561) 805-6732

Review Stop Z ZONING
Rev No 1 Status P Date 2012-12-21 Cont ID  
Sent By jroach Date 2012-12-21 Time 15:04 Rev Time 0.00
Received By jroach Date 2012-12-17 Time 13:54 Sent To  
Notes
***NONE***