Plan Review Details - Permit 12110721
| Plan Review Stops For Permit 12110721 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-11-29 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-11-29 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-11-29 |
Time |
12:01 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-12-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2012-12-20 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2012-12-19 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2012-12-20 10:33:23 | GAVE TO T GORDON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-12-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-12-06 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-11-29 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-12-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2012-12-20 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2012-12-20 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-12-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-12-06 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-12-06 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2012-12-06 11:11:06 | *** CORRETCIONS NEEDED FOR MECHANICAL PLANS *** | | | | | | 1) PROVIDE A DETAIN SHOWING HOW MUA-1 UNIT IS TO BE | | | SECURED TO ROOF WITH, TYPE OF ANCHORS, SIZE, LOCATION, | | | ETC.. SEE 2010 FBC/M 301.12 AND 2010 FBC 1609.8. | | | 2) PROVIDE A DETAIN SHOWING HOW EXHAUST FANS ARE TO BE | | | SECURED TO ROOF WITH, TYPE OF ANCHORS, SIZE, LOCATION, | | | ETC.. SEE 2010 FBC/M 301.12 AND 2010 FBC 1609.8. | | | 3) PROVIDE A DETAIN SHOWING HOW THE DUCT STANDS ARE TO | | | BE SECURED TO ROOF AND DUCTS, WITH TYPE OF ANCHORS, | | | SIZE, LOCATION, ETC.. SEE 2010 FBC/M 301.12 AND 2010 | | | FBC 1609.8. | | | 4) PROVIDE A DETAIN SHOWING HOW ROOF CURBS ARE TO BE | | | SECURED TO ROOF WITH, TYPE OF ANCHORS, SIZE, LOCATION, | | | ECT.. SEE 2010 FBC/M 301.12 AND 2010 FBC 1609.8. | | | | | | MECHANICAL PLAN REVIEW BY TOM GORDON (HY-BYRD INC.) | | | FOR ASSISTANCE CALL LUIS MARTINEZ (561) 805-6710 |
|
|
|