Plan Review Details - Permit 12110645
| Plan Review Stops For Permit 12110645 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-02-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-06 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-06 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-23 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-23 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2013-01-23 13:04:34 | ****CORRECTIONS**** | | | **CONTRACTOR MAY SUBMIT PRODUCT APPROVAL FOR SINGLE | | | HUNG VIA EMAIL PER DISCUSSION** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. REVISE THE PLAN TO INCLUDE WINDOW SIZES IN INCHES. | | | IT IS NOT CLEAR WHETHER THE WINDOWS ARE 5' HIGH OR 50" | | | HIGH. REVISE THE PLAN TO INCLUDE ROOM DESIGNATIONS, FBC | | | R310, FBC EB 604.1. | | | | | | 2ND REVIEW, PLEASE REVISE AS REQUESTED. ALSO, INCLUDE | | | WINDOW TYPE PROPOSED FOR EACH OPENING. ONLY FIXED GLASS | | | WINDOW PRODUCT APPROVALS WERE SUBMITTED. THIS DOES NOT | | | COMPLY WITH BEDROOM EMERGENCY ESCAPE AND RESCUE | | | REQUIREMENTS. | | | | | | 2. OK - INCLUDED CURRENT DOCUMENT FOR CONTRACTOR. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-12-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-11 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-11 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2012-12-11 19:32:49 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. REVISE THE PLAN TO INCLUDE WINDOW SIZES IN INCHES. | | | IT IS NOT CLEAR WHETHER THE WINDOWS ARE 5' HIGH OR 50" | | | HIGH. REVISE THE PLAN TO INCLUDE ROOM DESIGNATIONS, FBC | | | R310, FBC EB 604.1. | | | | | | 2. THE SPECIFICATION FOR THE WOOD SHUTTERS ARE FROM | | | 1996 AND DO NOT COMPLY WITH FBC 2010. UPON REQUEST, A | | | CURRENT SPECIFICATION CAN BE PROVIDED FOR YOU FROM | | | ICC600. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-11-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-11-28 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-11-28 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-02-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-02-06 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-02-01 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2013-02-02 09:34:51 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-23 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-02 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2013-01-02 11:37:28 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-12-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-11 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-27 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2012-11-28 09:18:42 | SENT TO MISC1 BOX. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-11-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-11-28 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-11-28 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy