| 2012-12-04 09:02:32 | BUILDING PLAN REVIEW |
| | PERMIT: 12110592 |
| | ADD: 1401 FORUM WAY # 600 |
| | CONT: T & M DEVELOPMENT |
| | TEL: (561)2121398 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLEASE SEE FIRE & MECHANICAL REVIEWS FOR COMMENTS |
| | THAT PERTAIN TO THE BUILDING REVIEW. SHEET UNDER THE |
| | HEADING" THIS PROJECT SHALL COMPLY WITH", |
| | EXISTING FIRE SEPERATIONS AT ELEVATORS, STAIRS, |
| | BUILDING ELECTRICAL & MECHANICAL ROOMS, ARE NOT |
| | MODIFIED OR ALTERED IN ANY MANNER. |
| | |
| | SHEET A1 THE RECEPTION LOBBY (101) / ELEVATOR LOBBY |
| | INDICATES A WALL TAG TYPE P2 & P4. THESE WALLS ARE |
| | INDICATED AS NON-RATED WALLS. PLEASE REVIEW THE 2010 |
| | FBC-B 708.14.1 ELEVATOR LOBBY AND THE 7 EXCEPTIONS. THE |
| | PLANS DO NOT INDICATE THE ELEVATOR SHAFT TO BE |
| | PRESSURIZED IN ACCORDANCE WITH 708.14.2 SEE EXCEPTION # |
| | 6. IT APPEARS WITH THE PARTITION TYPE P2 & P4 BEING |
| | DEPICTED FROM FLOOR TO CONCRETE DECK ABOVE THEY ARE |
| | BEING BUILT AS EITHER 1 HOUR FIRE RATING OR A SMOKE |
| | PARTITION (EXCEPTION #5) WOULD NEED TO MEET THE |
| | REQUIREMENTS LISTED WITHIN THE EXCEPTION, THE |
| | MECHANICAL PLANS DO NOT INDICATE THE USE OF ANY FIRE |
| | DAMPERS IN THIS LOCATION. |
| | IF THE P-4 WALL IS GOING TO BE BUILT AS A FIRE |
| | PARTITION THEN THE TEMPERED GLASS WINDOW WILL ALSO NEED |
| | TO QUALIFY UNDER THE REQUIREMENTS OF OPENING |
| | PROTECTIVES SEE TABLE 715.5 FOR FIRE PARTITION AND |
| | REQUIRED 3/4 HR WINDOW ASSEMBLY RATING. |
| | |
| | 2) THE PLANS LACK IN PROVIDING THE MINIMUM PLAN REVIEW |
| | CRITERIA FOR COMMERCIAL BUILDINGS: |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 107.3.5.1.1 BUILDING |
| | 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL |
| | INCLUDE THE FOLLOWING COMPONENTS: |
| | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS |
| | |
| | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: |
| | SCHEMATIC FIRE SPRINKLERS |
| | |
| | 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL |
| | INCLUDE THE FOLLOWING REQUIREMENTS: |
| | HIGH RISE 907.2.13 FIRE ALARMS |
| | |
| | 7. LIFE SAFETY PLAN, OCCUPANCY LOAD/EGRESS REQUIREMENTS |
| | SHALL INCLUDE: |
| | OCCUPANCY LOAD |
| | GROSS |
| | NET |
| | MEANS OF EGRESS |
| | EXIT ACCESS |
| | EXIT |
| | |
| | 107.3.5.1.2 ELECTRICAL |
| | |
| | 4. EMERGENCY SYSTEMS LIGHTING |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |