Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-18 Cont ID  
Sent By shill Date 2012-12-18 Time 12:05 Rev Time 0.00
Received By shill Date 2012-12-18 Time 12:05 Sent To E
Notes
2012-12-18 12:12:04****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PLANS TO BE ARCHITECTURAL QUALITY, TO SCALE, AND ARE
 TO CLEARLY SHOW SCOPE AND CODE COMPLIANCE. PROVIDE A
 STRUCTURAL DETAIL, INCLUDING WIND DESIGN CRITERIA, FOR
 THE PROPOSED WALL. ALL CONNECTIONS TO BE SPECIFIED.
 CALCULATIONS MAY BE REQUIRED. FBC RESIDENTIAL 301.
 THERE IS NO INFORMATION AS TO HOW THE PROPOSED
 IMPROVEMENT (BLOCK) WILL BE STRUCTURALLY CONTINUOUS
 WITH THE EXISTING (FRAME). NO BEAM SHOWN AT TOP, ONLY
 EXISTING WOOD BEAM. PLANS SHOW 3" COLUMNS, DO NOT
 SPECIFY MATERIAL, ASSUME THIS IS STEEL, BUT NOT CLEAR
 HOW THIS WILL TIE INTO THE PROPOSED NEW CONSTRUCTION.
  
 2. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED,
 561-233-5025 FOR MORE INFORMATION.
  
 3. ENERGY CALC REQUIRED FBC 2010 ENERGY CONSERVATION
 103.2.1.1.1.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-12-19 Cont ID  
Sent By rlecky Date 2012-12-19 Time 09:50 Rev Time 0.00
Received By rlecky Date 2012-12-19 Time 09:43 Sent To  
Notes
2012-12-19 09:53:05PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL.
 ON A FLOOR PLAN SHOW THE LOCATION OF ALL NEW LIGHTING
 OUTLETS, RECEPTACLE OUTLETS AND SMOKE DETECTORS. NEC
 215.5, 210.50
  
 INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER
 RESISTANT. NEC 406.11
  
 ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE
 PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC
 210.12
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-12-19 Cont ID  
Sent By shill Date 2012-12-19 Time 09:53 Rev Time 0.00
Received By rlecky Date 2012-11-15 Time 09:44 Sent To  
Notes
2012-11-19 09:44:44IN ZONING BOX

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-12-18 Cont ID  
Sent By shill Date 2012-12-18 Time 12:12 Rev Time 0.00
Received By shill Date 2012-12-18 Time 12:12 Sent To  
Notes
2012-12-18 12:12:42IMPACT FEE ASSESSMENT REQUIRED, 561-233-5025

Review Stop Z ZONING
Rev No 1 Status P Date 2012-11-21 Cont ID  
Sent By mdekle Date 2012-11-21 Time   Rev Time 0.00
Received By mdekle Date 2012-11-19 Time 13:08 Sent To B
Notes
2012-11-21 13:07:50DUE TO ATTACHED LETTER FROM PROPERTY OWNER, ZONING WAS
 ABLE TO CONDUCT REVIEW W/O SURVEY AND MEASURED
 DISTANCES VIA AERIAL PHOTOGRAPHS, ETC. PROPOSED
 IMPROVEMENTS DO NOT ENCROACH INTO THE REQUIRED BUILDNG
 SETBACKS. ALL IMPROVEMENTS WILL BE UNDER THE EXISTING
 ROOF LINE OF THE PREVIOUSLY APPROVED SINGLE FAMILY HOME
 (CARPORT AREA).