Plan Review Details - Permit 12110275
Plan Review Stops For Permit 12110275
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-04-02 Cont ID  
Sent By jwitmer Date 2013-04-02 Time 10:42 Rev Time 0.00
Received By jwitmer Date 2013-04-02 Time 10:42 Sent To  
Notes
2013-04-02 10:42:44BUILDING PLAN REVIEW
 PERMIT: 12110275
 ADD: 3401 PARKER AVE
 CONT: HEDRICK BROTHERS
 CONTACT: DON JONES
 TEL: (561)689-8880
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW- SCORER'S TOWER & CONCESSION STAND
 APRIL 02/ 2013
  
 BUILDING PROVISO:
  
 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING, FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-05 Cont ID  
Sent By jwitmer Date 2012-12-05 Time 16:39 Rev Time 0.00
Received By jwitmer Date 2012-12-05 Time 13:41 Sent To  
Notes
2012-12-05 16:34:03BUILDING PLAN REVIEW
 PERMIT: 12110275
 ADD: 3401 PARKER AVE
 CONT: HEDRICK BROTHERS
 CONTACT: DON JONES
 TEL: (561)689-8880
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW- PRESS BOX
 DEC. 5/ 2012
 ACTION: DENIED
  
 1) THE S-2 SHEET FOUNDATION NOTE # 4 INDICATES THERE TO
 BE A SOILS REPORT SUBMITTED. 2010 FBC-B 1803.1 GENERAL.
 GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN
 ACCORDANCE WITH SECTION 1803.2 AND REPORTED IN
 ACCORDANCE WITH SECTION 1803.6. WHERE REQUIRED BY THE
 BUILDING OFFICIAL OR WHERE GEOTECHNICAL INVESTIGATIONS
 INVOLVE IN-SITU TESTING, LABORATORY TESTING OR
 ENGINEERING CALCULATIONS, SUCH INVESTIGATIONS SHALL BE
 CONDUCTED BY A REGISTERED DESIGN PROFESSIONAL.
  
 2) SHEET PBA-3 DETAIL # 1 AND SHEET PBS-3 DETAIL # 7
 DEPICTS AN AREA OF CONCEALED HORIZONTAL TO VERTICAL
 SPACES REQUIRING FIRE BLOCKING PER 2010 FBC-B 717.2.3.
  
 3) SHEET PBA-3 DETAIL # 1 WILL ALSO NEED FIRE BLOCKING
 AT THE TOP AND BOTTOM OF THE RUN. 2010 FBC-B 717.2.4
 STAIRWAYS. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED
 SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF
 THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL ALSO COMPLY
 WITH SECTION 1009.6.3.
  
 4) SHEET PBA-3 DETAIL # 1 THE PLUMBING CHASE VERSES THE
 STAIR STRINGERS, MISSING RATED CEILING. 2010 FBC-B
 1009.6.3 ENCLOSURES UNDER STAIRWAYS. THE WALLS AND
 SOFFITS WITHIN ENCLOSED USABLE SPACES UNDER ENCLOSED
 AND UNENCLOSED STAIRWAYS SHALL BE PROTECTED BY 1-HOUR
 FIRE-RESISTANCE-RATED CONSTRUCTION OR THE
 FIRE-RESISTANCE RATING OF THE STAIRWAY ENCLOSURE,
 WHICHEVER IS GREATER.
  
 5) SHEET PBA-3 DETAIL # 1 & 2 BOTH DEPICT AN ENLARGE
 DETAIL #2/ PBA 4 PLEASE PROVIDE CLARIFICATION BETWEEN
 THE WRITTEN STATEMENT AND DETAIL. IT APPEARS THE ROOF
 TILE WILL BE ATTACHED TO EITHER GYPSUM SHEATHING OR CDX
 PLYWOOD, IT APPEARS THAT THE INSULASION WILL BE
 SANDWICHED BETWEEN THE TWO LAYERS, PLEASE CLARIFY. THE
 CONCERNS ARE THAT THE FINISHED DECKING WILL MATCH WITH
 THE TYPE DECK FOUND IN THE ROOFING PRODUCT APPROVAL.
 THE SECOND ISSUE OR CONCERN IS THE 5 1/2 INCH THICK
 INSULATION APPEARS TO BE ON TOP OF THE TRUSSES, WHAT
 TYPE OF FASTENERS WILL BE HOLDING DOWN THE ROOF DECK?
 ADDITIONAL INFORMATION REQUIRED 107.1.2,
  
 6) SHEET PBA-1 FIRST FLOOR PLAN, PLEASE PROVIDE
 MANUFACTURERS ADDITIONAL INFORMATION ON THE INCLINED
 STAIRWAY CHAIR LIFT. THE CHAIRLIFT WILL NEED TO COMPLY
 WITH :
 2010 FBC-B 410.1 GENERAL. PLATFORM LIFTS SHALL COMPLY
 WITH ASME A18.1 (1999 EDITION OR 2003 EDITION)
 (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS"
 IN CHAPTER 1). PLATFORM LIFTS SHALL NOT BE
 ATTENDANT-OPERATED AND SHALL PROVIDE UNASSISTED ENTRY
 AND EXIT FROM THE LIFT.
 ADVISORY 410.1 GENERAL.
 INCLINED STAIRWAY CHAIRLIFTS AND INCLINED AND VERTICAL
 PLATFORM LIFTS ARE AVAILABLE FOR SHORT-DISTANCE
 VERTICAL TRANSPORTATION. BECAUSE AN ACCESSIBLE ROUTE
 REQUIRES AN 80 INCH (2030 MM) VERTICAL CLEARANCE, CARE
 SHOULD BE TAKEN IN SELECTING LIFTS AS THEY MAY NOT BE
 EQUALLY SUITABLE FOR USE BY PEOPLE USING WHEELCHAIRS
 AND PEOPLE STANDING. IF A LIFT DOES NOT PROVIDE 80 INCH
 (2030 MM) VERTICAL CLEARANCE, IT CANNOT BE CONSIDERED
 PART OF AN ACCESSIBLE ROUTE IN NEW CONSTRUCTION.
 THE ADA AND OTHER FEDERAL CIVIL RIGHTS LAWS REQUIRE
 THAT ACCESSIBLE FEATURES BE MAINTAINED IN WORKING ORDER
 SO THAT THEY ARE ACCESSIBLE TO AND USABLE BY THOSE
 PEOPLE THEY ARE INTENDED TO BENEFIT. BUILDING OWNERS
 ARE REMINDED THAT THE ASME A18 SAFETY STANDARD FOR
 PLATFORM LIFTS AND STAIRWAY CHAIRLIFTS REQUIRES ROUTINE
 MAINTENANCE AND INSPECTIONS. ISOLATED OR TEMPORARY
 INTERRUPTIONS IN SERVICE DUE TO MAINTENANCE OR REPAIRS
 MAY BE UNAVOIDABLE; HOWEVER, FAILURE TO TAKE PROMPT
 ACTION TO EFFECT REPAIRS COULD CONSTITUTE A VIOLATION
 OF FEDERAL LAWS AND THESE REQUIREMENTS.
  
 7) SHEET PBA-1 THE ACCESSIBLE RESTROOM STALLS APPEAR TO
 HAVE A SIZE PROBLEM IN THE WIDTH THE PLANS TOTAL UP TO
 7'-0" IN LENGTH. THE NEW 2010 FL ACCESSIBLITY CODE
 REQUIRES A 60 INCH CLEAR WIDTH FOR THE WATER CLOSET
 FROM THE WALL, THE LAVATORY CAN NOT PATRUDE INTO THIS
 SPACE (604.3.2). THE PLAN ALSO INDICATES THE LAV
 CENTERED 1'-7" FROM THE OTHER WALL. THAT ONLY ALLOWS
 FROM THE CENTER OF THE SINK TO THE 60 INCHES A
 MEASUREMENT OF 5 INCHES. THE MINIMUM ROOM SIZE THAT
 APPEARS TO WORK WOULD BE 7'-1" WITH THE SINK CENETERED
 AT 15 INCHES OFF THE WALL WITH A 19-20" LAV. FIGURE
 604.8.1.6.
  
 8) PBA-3 SCORERS TOWER IS INDICATED TO HAVE 439 SQ FT
 AND AN OPEN STAIRWELL, UNDER 2010 FBC-B 1022.1
 EXCEPTION 1 AND OCCUPANT LOAD LESS THAN TEN AND 1.1 AND
 THE STAIRWAY IS OPEN TO NOT MORE THAN ONE STORY ABOVE
 ITS LEVEL OF EXIT DISCHARGE THIS IS ACCEPTABLE UNDER
 THE FBC. IF THE FIRE CODES ARE MORE STRINGENT THEN WE
 MUST GO WITH THE MOST STRINGENT OF THE TWO CODES.
  
 9) PBA-3 SCORERS TOWER IF THE OPEN STAIRWELL IS TO STAY
 OPEN THEN THE STEM WALL WILL BECOME THE GAURD PLEASE
 PROVIDE A VERTICAL DIMENSION FOR THIS WALL PROVIDING
 CODE COMPLIANCE, 2010 FBC 1013.2 HEIGHTS 42 INCHES.
  
 10) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 11) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING, FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 NOTE, THE PRESSURES FOR COMPONENTS & CLADDING ARE OK!
 IF THE CONTRACTOR ELECTS NOT SUBMIT PRODUCT APPROVALS
 BEFORE THE TIME OF PERMIT ISSUANCE THEN THEY WILL BE
 CONSIDERED REVISIONS AND ASSOCIATED REVIEWS AND FEES
 WILL OCCUR. A WRITTEN RESPONCE INDICATING PRODUCT
 APPROVALS WOULD BE SUBMITTED LATER WOULD PROVIDE AS
 WRITTEN NOTICE OF YOUR INTENT.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-11-20 Cont ID  
Sent By rlecky Date 2012-11-20 Time 11:52 Rev Time 0.00
Received By rlecky Date 2012-11-20 Time 11:07 Sent To  
Notes
2012-11-20 11:53:38THE FOLLOWING CODE REQUIREMENT WAS NOTED ON THE PLAN.
  
 ELECTRIC DRINKING FOUNTAINS SHALL BE PROTECTED WITH
 GFCI PROTECTION. NEC 422.52
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2013-05-01 Cont ID  
Sent By MGONZALE Date 2013-05-01 Time   Rev Time 1.00
Received By mgonzale Date 2013-05-01 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2012-12-31 Cont ID  
Sent By Mgonzale Date 2012-12-31 Time   Rev Time 0.25
Received By mgonzale Date 2012-12-28 Time   Sent To I
Notes
2012-12-31 07:17:16#1 LOCATE AND SHOW ON PLAN ALL EXISTING CITY OF WPB
 UTILITIES.
  
 #2 SHOW DOMESTIC WATER METER AND BACKFLOW,
  
 #3 CITY STANDARD DETAIL MUST BE INCLUDED.
  
 #4 SHOW SEWER SERVICE LATERAL AND SERVICE CLEAN-OUT
 LOCATION.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-04-01 Cont ID  
Sent By wjolin Date 2013-04-01 Time 13:43 Rev Time 0.00
Received By wjolin Date 2013-04-01 Time 13:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-11-19 Cont ID  
Sent By wjolin Date 2012-11-19 Time 14:23 Rev Time 0.00
Received By wjolin Date 2012-11-19 Time 13:40 Sent To  
Notes
2012-11-19 14:23:533401 PARKER AVENUE - PRESS BOX
 PERMIT #12110275
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE A NAME, ADDRESS OR LETTER ON THE BUILDING SO
 THE LOCATION CAN BE IDENTIFIED BY EMERGENCY RESPONDERS.
 NUMBERS/LETTERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT
 WITH 1-INCH STROKE AND SHALL CONTRAST THE BACKGROUND.
  
 STRUCTURES WITH LIGHT FRAME ROOF TRUSS CONSTRUCTION
 SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO THE
 BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE LETTER R.
  
 INDICATE THE LOCATION OF THE NEAREST FIRE HYDRANT(S).
  
 THE UNDERSIDE OF OF INTERIOR STAIRWAYS, IF OF
 COMBUSTIBLE CONSTRUCTION, SHALL BE PROTECTED TO PROVIDE
 NOT LESS THAN 1-HOUR FIRE RESISTANCE.
  
 THE EXIT STAIR ENCLOSURE IS NOT PERMITTED TO BE OPEN ON
 THE UPPER FLOOR.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 NO COOKING SHALL BE PERMITTED IN THE CONCESSION STAND
 UNLESS A TYPE I EXHAUST HOOD AND AUTOMATIC SUPPRESSION
 SYSTEM IS INSTALLED.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-05-03 Cont ID  
Sent By shill Date 2013-05-03 Time 11:56 Rev Time 0.00
Received By shill Date 2013-03-11 Time 13:22 Sent To  
Notes
2013-03-12 13:22:21C--24

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-01-14 Cont ID  
Sent By lmartine Date 2012-12-31 Time 14:02 Rev Time 0.00
Received By lmartine Date 2012-11-09 Time 16:18 Sent To  
Notes
2012-11-09 16:19:43INCOMING SENT TO C27. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status N Date 2013-05-29 Cont ID  
Sent By jwitmer Date 2013-05-29 Time 09:28 Rev Time 0.00
Received By jwitmer Date 2013-05-29 Time 09:28 Sent To  
Notes
2013-05-29 09:28:55MSP-1
 IMPACT FEE ASSESSMENT: EXISTING USE CREDIT
 W M SWOOPE

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-04-02 Cont ID  
Sent By jwitmer Date 2013-04-02 Time 10:44 Rev Time 0.00
Received By jwitmer Date 2013-04-02 Time 10:44 Sent To  
Notes
2013-04-02 10:45:13BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-12-05 Cont ID  
Sent By jwitmer Date 2012-12-05 Time 16:34 Rev Time 0.00
Received By jwitmer Date 2012-12-05 Time 16:34 Sent To  
Notes
2012-12-05 16:34:20BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-12-11 Cont ID  
Sent By lmartine Date 2012-12-11 Time 15:12 Rev Time 0.00
Received By lmartine Date 2012-12-11 Time 15:12 Sent To  
Notes
2012-12-11 15:39:44*** PROVISO ***
 1) 2010 FBC 1503.7, CONDENSATE LINES AND ROOF
 DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT (305 MM)
 AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY
 UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS.
  
 2) PTAC UNIT NEEDS TO BE A MINIMUM EER OF 12.5, SEE
 2010 FBC/ENERGY TABLE 503.2.3 (3).

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-11-20 Cont ID  
Sent By lwagner Date 2012-11-20 Time 14:25 Rev Time 0.00
Received By lwagner Date 2012-11-20 Time 13:47 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2013-04-02 Cont ID  
Sent By jwitmer Date 2013-04-02 Time 10:43 Rev Time 0.00
Received By jwitmer Date 2013-04-02 Time 10:43 Sent To  
Notes
2013-04-02 10:44:23ROOF
 BUILDING PLAN REVIEW
 PERMIT: 12110275
 ADD: 3401 PARKER AVE
 CONT: HEDRICK BROTHERS
 CONTACT: DON JONES
 TEL: (561)689-8880
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW- SCORER'S TOWER & CONCESSION STAND
 APRIL 02/ 2013
  
 BUILDING PROVISO:
  
 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING, FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop Z ZONING
Rev No 2 Status P Date 2013-03-29 Cont ID  
Sent By jroach Date 2013-03-29 Time 13:29 Rev Time 0.00
Received By jroach Date 2013-03-14 Time 18:25 Sent To  
Notes
2013-03-29 13:30:34AS THERE ARE STILL INCONSISTENCIES BETWEEN THE APPROVED
 SITE/MASTER PLAN AND THE PROPOSED SITE/MASTER PLAN
 (REGARDING THE PLAZA SURROUNDING THE BUILDING), THIS
 PERMIT IS ISSUED WITH THE FOLLOWING PROVISO...
  
 PROVISO
  
 1. THIS PERMIT / APPROVAL SHALL BE ONLY FOR THE
 CONSTRUCTION OF THE SCORER?S / CONCESSIONS BUILDING.
 ALL CONSTRUCTION ASSOCIATED WITH THE SURROUNDING PLAZA
 SHALL BE SUBMITTED UNDER A SEPARATE PERMIT APPLICATION.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2012-12-04 Cont ID  
Sent By jroach Date 2012-12-04 Time 13:25 Rev Time 0.00
Received By jroach Date 2012-11-28 Time 10:57 Sent To  
Notes
2012-12-04 13:25:34ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 12.03.2012
 PERMIT NO.: 12110275
 ADDRESS: 3401 PARKER AVENUE
 CONTRACTOR/CONTACT: DON JONES - HEDRICK BROTHERS
 TELEPHONE NO.: 561.689.8880
 SCOPE OF REVIEW: PRESS BOX.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PLEASE PROVIDE TWO (2) COPIES OF A CURRENT AND
 ACCURATE SURVEY.
  
 2. PRIOR TO THE ISSUANCE OF A PERMIT FOR THE PRESS BOX,
 A SEPARATE LANDSCAPE PERMIT SHALL BE SUBMITTED
 PROVIDING FOR THE INSTALLATION OF ALL LANDSCAPING
 WITHIN THE VICINITY OF THE PRESS BOX AND ALL
 SURROUNDING PARKING AREAS. THE LANDSCAPE PERMIT
 APPLICATION SHALL BE SUBMITTED WITH TWO (2) SETS OF
 SIGNED/SEALED LANDSCAPE PLANS, AS WELL AS A CERTIFIED
 COST ESTIMATE FOR THE INSTALLATION AND MATERIAL OF THE
 PROPOSED LANDSCAPING. PLEASE COORDINATE WITH CALVIN
 CAMPBELL REGARDING THIS AS SEVERAL DISCUSSIONS HAVE
 OCCURRED TO DATE REGARDING THE PHASING OF THE
 LANDSCAPING.
  
 3. PLEASE CLARIFY THE INCLUSION OF THE SITE PLAN
 ELECTRICAL (SPE) SHEETS. ALL SITE LIGHTING WAS
 PERMITTED UNDER PERMIT #11080127. ADDITIONALLY, THE
 CONFIGURATION AND LAYOUT OF THE SITE SHOWN ON THESE
 SHEETS DIFFERS FROM THAT WHICH HAS BEEN APPROVED AND
 CONSTRUCTED TO-DATE.
  
 4. THE PLAZA AND LANDSCAPE PLANTER CONFIGURATION SHOWN
 ON SHEET PBSP-1 DOES NOT MATCH THE SITE AND LANDSCAPE
 PLANS APPROVED AS PART OF THE PBAU ATHLETIC COMPLEX
 COMMUNITY SERVICE PLANNED DEVELOPMENT (CSPD). IF THE
 CONFIGURATION IS PROPOSED TO BE MODIFIED, A MINOR
 AMENDMENT TO THE CSPD SHALL BE SUBMITTED TO AND
 APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ?
 PLANNING DIVISION, PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE PRESS BOX.
 __________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.WPB.ORG
  
2012-11-15 14:05:3611/15/12


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved