Plan Review Details - Permit 12100920
Plan Review Stops For Permit 12100920
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-11-15 Cont ID  
Sent By jwitmer Date 2012-11-15 Time 10:46 Rev Time 0.00
Received By jwitmer Date 2012-11-15 Time 10:46 Sent To  
Notes
2012-11-15 10:47:58ANCHORAGE FOR MANUFACTURED BUILDING, SIZE AND BOLT
 LAYOUT FOUND ON STATE APPROVED SHEET 6 OF 14. JW

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-11-30 Cont ID  
Sent By rlecky Date 2012-11-30 Time 12:19 Rev Time 0.00
Received By rlecky Date 2012-11-30 Time 12:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-11-15 Cont ID  
Sent By rlecky Date 2012-11-15 Time 09:46 Rev Time 0.00
Received By rlecky Date 2012-11-14 Time 16:30 Sent To  
Notes
2012-11-15 09:48:48 
 12100920
 901 45TH STREET
 GENERATOR INSTALLATION
  
 PLEASE ADDRESS THE FOLLOWING ELECTRICAL PLAN REVIEW
 COMMENTS.
  
 VERIFY THE REQUIRED SAFETY CLEARANCES ARE BEING
 OBSERVED WITHIN THE GENERATOR ENCLOSURE TO ALL
 ELECTRICAL EQUIPMENT. NEC 110.26
  
 INDICATE THE FEEDER CONDUCTOR SIZE PROPOSED FROM THE
 NEW GENERATOR TO THE SWITCHBOARD.
 NEC 445.13
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-11-03 Cont ID  
Sent By wjolin Date 2012-11-03 Time 17:09 Rev Time 0.00
Received By wjolin Date 2012-11-03 Time 16:28 Sent To  
Notes
2012-11-03 17:09:36SEPARATE PLANS AND PERMIT NEEDED FOR TEMPORARY
 CONSTRUCTION TRAILER(S).

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-12-05 Cont ID  
Sent By lmartine Date 2012-12-05 Time 14:09 Rev Time 0.00
Received By lmartine Date 2012-10-30 Time 13:51 Sent To  
Notes
2012-10-31 13:51:43SENT TO C10 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-12-05 Cont ID  
Sent By lmartine Date 2012-12-05 Time 13:41 Rev Time 0.00
Received By lmartine Date 2012-12-05 Time 13:41 Sent To  
Notes
2012-12-05 13:52:39*** PROVISO ***
 1) ALL FUEL PIPING TO COMPLY WITH NFPA 37 AND 2010
 FBC/FUEL GAS.
 2) ALL EXHAUST PIPING & DUCTS TO COMPLY WITH NFPA 37
 AND 2010 FBC/M.
 MECHANICAL PLAN REVIEW BY: TOM GORDON (HY-BYRD INC.)
 FOR ASSISTANCE CALL LUIS MARTINEZ (561) 805-6710

Review Stop Z ZONING
Rev No 1 Status N Date 2012-11-08 Cont ID  
Sent By avann Date 2012-11-08 Time 14:28 Rev Time  
Received By ajones Date 2012-11-05 Time   Sent To  
Notes
***NONE***