| 2012-12-05 16:57:31 | RESIDENTIAL (R3) ADDITION/ALTERATION LEVEL 2 BUILDING |
| | REVIEW COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- PROPERTY IS LOCATED IN FLOOD ZONE A5. THE ADDITION |
| | MINIMUM FINISH FLOOR ELEVATION NEEDS TO BE 7'-6" AND |
| | THE EXISTING STRUCTURE NEEDS TO BE RAISED TO 7'-6" AS |
| | WELL AS REQUIRED BY CITY ORDINANCE SEC. 94-546(B)(1) |
| | FOR ADDITIONS AND SUBSTANTIAL IMPROVEMENTS DONE OVER |
| | 50% OF THE LIFE OF THE STRUCTURE. REVISE PLANS AS |
| | REQUIRED. SEC. 1003.5 OF 2010 FBC-EXISTING BUILDING. |
| | |
| | 2- ACCORDING TO SEC. R301.2.1.4.3 OF 2010 |
| | FBC-RESIDENTIAL, THIS BUILDING IS LOCATED ON EXPOSURE |
| | "D" NOT "C". ARCHITECT TO REVISE DESIGN CRITERIA ON ALL |
| | DRAWINGS AND THE DESIGN PRESSURES FOR ALL DOORS AND |
| | WINDOWS ON ALL DRAWINGS AS REQUIRED. |
| | |
| | 3- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT |
| | FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY |
| | OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY |
| | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| | CODE. |
| | |
| | 4- PLANS SHOW AND EXISTING GENERATOR TO REMAIN. |
| | ACCORDING TO CITY RECORDS THERE IS NOT PERMIT FOR THIS |
| | GENERATOR. PROVIDE PROOF OF PERMIT OR APPLY FOR A |
| | SEPARATE PERMIT AS REQUIRED BY SEC. 105.1 CITY |
| | AMENDMENTS TO FBC. ALSO, THE FINISH FLOOR ELEVATION OF |
| | THIS EQUIPMENT NEEDS TO BE 7'-6" MIN. |
| | |
| | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) METAL ROOF TO BE INSTALLED. |
| | |
| | B) WINDOW MULLIONS FOR NEW BAY WINDOW AS SHOWN ON PLANS |
| | BY THE MASTER BATHROOM. AND CLEARLY SPECIFY MULLION |
| | SIZE AND ANCHORS. |
| | |
| | C) FLAT ROOF FOR COVERED PATIO. NOTE: CLEARLY IDENTIFY |
| | ON PRODUCT APPROVAL THE FOLLOWING (1) WHICH FLAT ROOF |
| | APPROVED ASSEMBLY IS GOING TO BE INSTALLED. (2) BASE |
| | SHEET FASTENING OPTION IF MORE THAN ONE OPTION. (3) RAS |
| | 117 CALCULATIONS FOR REQUIRED NAIL ENHANCING AT |
| | PERIMETER AND CORNER AREAS. SIGNED AND SEALED IF |
| | REQUIRED BY THE PRODUCT APPROVAL SUBMITTED. |
| | |
| | D) MULLIONS FOR ENTRY DOOR TRANSOM ASSEMBLY. AND, |
| | CLEARLY IDENTIFY MULLION SIZE AND ANCHORS TO BE |
| | INSTALLED. |
| | |
| | E) ENTRY DOORS AS SHOWN ON PLANS. EXTERIOR FRONT |
| | ELEVATION SHOWS DOOR WITH GLASS PANEL. NOA SUBMITTED IS |
| | FOR SOLID DOORS. ALSO, NOA 09-0312.14 SUBMITTED WAS |
| | SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE |
| | AND PROVIDE CURRENT NOA. REVISE ELEVATION AND PRODUCT |
| | APPROVAL TO MATCH. |
| | |
| | 6- ARCHITECT OF RECORD TO REVIEW AND APPROVE ABOVE |
| | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS TO FBC. |
| | |
| | 7- ARCHITECT TO PROVIDE GARAGE DOOR STRUCTURAL BUCK |
| | DETAIL. SPECIFY SIZE AND FASTENER TYPE SIZE AND SPACING |
| | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. |
| | R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 8- ENERGY CALCULATIONS. SEC. 103.2 OF 2010 FBC-ENERGY |
| | CONSERVATION: |
| | A) REVISE TYPE OF DOORS ON SHEET 3 OF 6. SEE PLANS AND |
| | PRODUCT APPROVALS SUBMITTED AND REVISE AS REQUIRED TO |
| | MATCH. |
| | |
| | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. |
| | |
| | C) COMPLETE AL THE INFORMATION ON TOP OF FORM, |
| | INCLUDING BUILDER'S NAME. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |
| | |
| | |
| | |
| | FW: 116 ARLINGTON PLACE - PERMIT # 12100772 |
| | |
| | ROBERT BROWN |
| | TO: |
| | JULIO GOMEZ |
| | 04/03/2013 02:01 PM |
| | |
| | |
| | CC: |
| | LUIS MARTINEZ |
| | |
| | |
| | |
| | |
| | FROM: ROBERT BROWN/WESTPALM |
| | |
| | TO: JULIO GOMEZ/WESTPALM@WESTPALM |
| | |
| | CC: LUIS MARTINEZ/WESTPALM@WESTPALM |
| | |
| | |
| | |
| | |
| | |
| | JULIO, |
| | THE OWNER HAS OBTAINED THE ATTACHED APPRAISAL, FROM A |
| | LICENSED APPRAISER, WHICH STATES THAT THE IMPROVEMENT |
| | VALUE (I.E. EXCLUDING THE VALUE OF THE LOT) IS |
| | $250,000. THE ATTACHED LETTER FROM THE ARCHITECT SHOWS |
| | THAT BASED ON THE APPRAISED VALUE AND THE VALUE OF THE |
| | IMPROVEMENTS, THE ADDITION WOULD NOT BE CONSIDERED |
| | SUBSTANTIAL IMPROVEMENT AS DEFINED IN FEMA SUBSTANTIAL |
| | IMPROVEMENT/SUBSTANTIAL DAMAGE DESK REFERENCE FEMA |
| | P-758. PER THE DESK REFERENCE, FOR A LATERAL ADDITION, |
| | WHICH IS NOT A SUBSTANTIAL IMPROVEMENT, ON A PRE-FIRM |
| | HOUSE, THE ADDITION IS NOT REQUIRED TO COMPLY WITH THE |
| | FLOOD ELEVATION REQUIREMENTS. |
| | PLEASE REVIEW THE ATTACHED DOCUMENTS AND CONFIRM THAT |
| | YOU AGREE WITH THAT ASSESSMENT. PLEASE CALL THE |
| | ARCHITECT, JACK HAWK, AT (945) 360 7303, TO ADVISE HIM |
| | OF OUR DECISION, AND THEN PRINT AND FILE THE ATTACHED |
| | DOCUMENTS WITH THE PERMIT APPLICATION. |
| | |
| | THANKS |
| | ROBERT BROWN, CBO |
| | BUILDING OFFICIAL / BUILDING DIVISION MANAGER |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES DEPARTMENT ? BUILDING DIVISION |
| | (561) 805 6652 |
| | |
| | |
| | |
| | FW: 116 ARLINGTON PLACE - PERMIT # 12100772 |
| | |
| | ROBERT BROWN |
| | TO: |
| | JULIO GOMEZ |
| | 04/03/2013 02:01 PM |
| | |
| | |
| | CC: |
| | LUIS MARTINEZ |
| | |
| | |
| | |
| | |
| | FROM: ROBERT BROWN/WESTPALM |
| | |
| | TO: JULIO GOMEZ/WESTPALM@WESTPALM |
| | |
| | CC: LUIS MARTINEZ/WESTPALM@WESTPALM |
| | |
| | |
| | |