Plan Review Details - Permit 12100672
Plan Review Stops For Permit 12100672
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-11-30 Cont ID  
Sent By rmcdouga Date 2012-11-30 Time 16:00 Rev Time 0.00
Received By rmcdouga Date 2012-11-30 Time 15:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-11-09 Cont ID  
Sent By rlecky Date 2012-11-09 Time 16:42 Rev Time 0.00
Received By rlecky Date 2012-11-09 Time 16:28 Sent To  
Notes
2012-11-09 16:43:1212100672
 153 WORTH CT S.
 SFD RENOVATION
  
  
 THE FOLLOWING CODE REQUIREMENTS WERE NOTED ON THE PLAN.
  
 PROVISO:
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 THE NEW BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS.
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-12-10 Cont ID  
Sent By lwagner Date 2012-12-10 Time 13:55 Rev Time 0.00
Received By lwagner Date 2012-12-04 Time 13:09 Sent To  
Notes
2012-12-04 13:10:20SENT TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-11-30 Cont ID  
Sent By rmcdouga Date 2012-11-30 Time 16:00 Rev Time 0.00
Received By rmcdouga Date 2012-10-22 Time 17:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-12-10 Cont ID  
Sent By lwagner Date 2012-12-10 Time 13:55 Rev Time 0.00
Received By lwagner Date 2012-12-10 Time 13:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-11-19 Cont ID  
Sent By lwagner Date 2012-11-19 Time 14:40 Rev Time 0.00
Received By lwagner Date 2012-11-19 Time 14:31 Sent To  
Notes
2012-11-19 14:40:22FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 A SANITARY RISER DIAGRAM IS REQUIRED FOR THE PLUMBING.
 FBC 2010 LOCAL AMENDMENTS 107.3.5.1.3 - 11.PLUMBING:
 PLUMBING RISER
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 2 Status P Date 2012-12-07 Cont ID  
Sent By mdekle Date 2012-12-07 Time   Rev Time 0.00
Received By mdekle Date 2012-12-05 Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-10-24 Cont ID  
Sent By medkle Date 2012-10-24 Time   Rev Time  
Received By mdekle Date 2012-10-24 Time   Sent To  
Notes
2012-10-24 11:26:11ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 10.24.2012
 PERMIT NO.: 12100672
 ADDRESS: 153 WORTH CT. S.
 CONTRACTOR/CONTACT: THOMAS J. FOWLER II
 TELEPHONE NO.: 772.546.8113
 SCOPE OF REVIEW: INTERIOR RENOVATIONS, KITCHEN, 2
 BATHROOMS, INSTALL NEW IMPACT WINDOWS & DOORS. INSTALL
 NEW GARAGE DOOR.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
 1.THE APPLICANT IS REQUIRED TO SUBMIT A LANDSCAPE PLAN
 FOR THE PROPERTY. PURSUANT TO SECTION SEC. 94-441 OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS ("ZLDR"),
 THE PROPOSED RENOVATION ($70,000) EXCEEDS 50 PERCENT OF
 THE PROPERTY APPRAISER'S ASSESSED VALUE OF THE
 STRUCTURE ($102, 084) THEREFORE THE APPLICANT MUST
 SUBMIT A LANDSCAPE PLAN TO THE CITY WHICH DEMONSTRATES
 COMPLIANCE WITH SEC. 94-442 WHICH STATES THE FOLLOWING:
  
 94-442 (B) (2) A. SINGLE-FAMILY DWELLING UNITS. FOR
 SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHADE,
 FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. FOR
 SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHRUB SHALL
 BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR
 PORTION THEREOF.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
 WWW.CITYOFWPB.COM
  
  
  
  
  
  
  
  
  