| Plan Review Stops For Permit 12100670 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-12-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-28 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-28 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-12 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-12 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2012-12-12 16:25:22 | BUILDING PLAN REVIEW | | | PERMIT: 12100670 | | | ADD: 801 VILLAGE BLVD # 303-304 | | | CONT: PAGE CONTRACING | | | TEL: (954)868-4561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DEC. 12/ 2012 | | | ACTION:DENIED | | | | | | 1) SHEET A-2.01: | | | | | | 1A) COMPLIED. | | | | | | 1B) 2ND REQUEST PLEASE REVIEW OCCUPANT LOAD CHART AND | | | TOTAL OCCUPANCY LOAD. 2010 FBC-B TABLE 1004.1.1 FOR | | | DAYCARE THE OCCUPANT LOAD IS FIGURED AT 20 NET NOT THE | | | 35 SQ FT AS INDICATED, THE OFFICE, LOBBY AND KITCHEN DO | | | NOT INDICATE ANY OCCUPANT LOADS WITHIN THE CHART BUT | | | THE FLOOR PLAN DOES, PLEASE CORRECT THE OCCUPANT LOAD | | | FOR EACH ROOM WITHIN THE CHART, CORRECT THE SQ FT | | | REQUIRED FOR EACH OCCUPANT PER TABLE 1004.1. AAND | | | PROVIDE THE TOTAL OCCUPANT LOAD FOR THE DAYCARE | | | OCCUPANCY. | | | 2) SHEET A2.01: | | | | | | 2A) COMPLIED. | | | | | | 2B) COMPLIED. | | | | | | 3) COMPLIED. | | | | | | 4) 2ND REQUEST, SHEET E1 NOR THE LIFE SAFETY SHEEET | | | INDICATE COMPLIANCE WITH2010 EXISTING BLDG CODE 912.2.2 | | | FIRE ALAARM AND DETECTION SYSTEMS AND 2010 FBC-B 436.7 | | | DETECTION AND ALARM SYSTEMS . THE RESPONSE INDICATES | | | THAT FIRE ALARM AND FIRE SPRINKLER DRAWINGS ARE | | | REQUIRED FOR A GENERAL BUILDING PERMIT BUT NONE HAVE | | | BEEN PROVIDED. | | | 2010 WPB ADMINISTRATIVE CODE. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE | | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | | CODES. SUCH INFORMATION SHALL BE SPECIFICAND THE | | | TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN | | | PART... | | | | | | 5) COMPLIED.. | | | | | | 6) 2ND REQUEST. PLANSDO NOT INDICATE WALL FINISHES FOR | | | SPRINKLERED BUILDING PROVIDE COMPLIANCE WITH TABLE | | | 803.9 AND 806.1.2 COMBUSTIBLE DECORATIVE MATERIALS. | | | | | | 7) 2ND REQUEST. SHEET A2.02 THE NEW SIDEWALKS ON THE | | | BUILDING ARE 5'-0" WIDE CODE COMPLIANT FOR AN | | | ACCESSIBLE ENTRANCE AS DEPICTED IN FIGURE 404.2.4.1 (D) | | | REQUIRING 60" BUT THE NEW SIDEWALK ON THE SIDE OF THE | | | BUILDING IS ONLY 4'-0" WIDE A NEW NON-CODE COMPLIANT | | | ELEMENT, THE PORTION THAT IS DIRECTLY AGAINST THE | | | BUILDING. | | | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-11-14 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-11-14 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2012-11-14 09:41:15 | BUILDING PLAN REVIEW | | | PERMIT: 12100670 | | | ADD: 801 VILLAGE BLVD # 303-304 | | | CONT: PAGE CONTRACING | | | TEL: (954)868-4561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | NOV. 14/ 2012 | | | ACTION:DENIED | | | | | | 1) SHEET A-2.01: | | | | | | 1A) BUILDING DATA CHART INDICATES THIS IS A LEVEL II | | | ALTERATION. 2010 EXISTING BUILDING CODE PLEASE REVIEW | | | 901.3.1 PARTIAL CHANGE OF OCCUPANCY AND 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | THIS IS A CHANGE IN OCCUPANCY GOING FROM BUSINESS TO | | | DAYCARE. | | | | | | 1B) PLEASE REVIEW OCCUPANT LOAD CHART AND TOTAL | | | OCCUPANCY LOAD. 2010 FBC-B TABLE 1004.1.1 FOR DAYCARE | | | THE OCCUPANT LOAD IS FIGURED AT 20 NET NOT THE | | | 35 SQ FT AS INDICATED, THE TOTAL OCCUPANT LOAD IS | | | APPROXIMATELY 214 WITH THE SQ FT INCLUDED FOR OFFICE | | | STAFF. | | | | | | 2) SHEET A2.01: | | | | | | 2A) THE HARDWARE SCHEDULE DOESN'T INDICATE COMPLIANCE | | | WITH 436.3 BATHROOM DOORS. | | | | | | 2B) PLEASE REVIEW REQUIREMENTS FOR THE MAINTENACE ROOM/ | | | LAUNDRY UNDER 2010 FBC-B 436.6.2 FOR THE REQUIREMENT OF | | | A 1 HOUR FIRE RATING OF WALLS AND OPENING PROTECTION IN | | | ACCORDANCE WITH TABLE 715.4. | | | | | | 3) THE E1 SHEET INDICATES THE USE OF EXIT LIGHTS AND | | | BATTERY BACK UP ILLUMINATION UNITS WITH THE CORRIDOR | | | 103. 2010 FBC-B TABLE 1006. | | | | | | 4) SHEET E1 NOR THE LIFE SAFETY SHEEET INDICATE | | | COMPLIANCE WITH2010 EXISTING BLDG CODE 912.2.2 FIRE | | | ALAARM AND DETECTION SYSTEMS AND 2010 FBC-B 436.7 | | | DETECTION AND ALARM SYSTEMS . | | | | | | 5) SHEET A-2.1 INDICATES THE EXIT CORRIDOR WALLS TO BE | | | A WALL TAG TYPE D, AND NO INFORMATION ON THE CORRIDOR | | | CEILING TYPE, PLEASE PROVIDE COMPLIANCE WITH | | | 2010 FBC-B 436.8 CORRIDORS EXCEPTION # 1 CORRIDOR WALLS | | | FORMING SMOKE PARTITIONS IN ACCORDANCE WWITH 710. | | | | | | 6) PLANSDO NOT INDICATE WALL FINISHES FOR SPRINKLERED | | | BUILDING PROVIDE COMPLIANCE WITH TABLE 803.9 AND | | | 806.1.2 COMBUSTIBLE DECORATIVE MATERIALS. | | | | | | 7) SHEET A2.02 THE NEW SIDEWALKS ON THE BUILDING ARE | | | 5'-0" WIDE CODE COMPLIANT FOR AN ACCESSIBLE ENTRANCE AS | | | DEPICTED IN FIGURE 404.2.4.1 (D) REQUIRING 60" BUT THE | | | NEW SIDEWALK ON THE SIDE OF THE BUILDING IS ONLY 4'-0" | | | WIDE A NEW NON-CODE COMPLIANT ELEMENT. | | | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2012-12-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-12-27 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-12-27 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2012-12-21 16:11:43 | NEW SHEET E2. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-12-19 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-12-19 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-11-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-11-14 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-11-14 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2012-11-14 15:24:36 | 12100670 | | | 801 VILLAGE BLVD. #303 | | | COMMERCIAL REMODEL ? DAYCARE | | | | | | PLEASE ADDRESS THE FOLLOWING ELECTRICAL PLAN REVIEW | | | COMMENTS. | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE PLAN SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | ELECTRIC DRINKING FOUNTAINS SHALL BE PROTECTED WITH | | | GFCI PROTECTION. NEC 422.52 | | | ALL RECEPTACLES LOCATED WITH IN SIX FEET OF A SINK MUST | | | BE GFCI PROTECTED. NEC 210.8 | | | A FIRE ALARM SYSTEM IS REQUIRED. FBC 436.7 | | | A SMOKE DETECTION SYSTEM IS REQUIRED. FBC 436.7.2 | | | | | | NOTE: | | | SEPARATE PERMITS ARE REQUIRED FOR VOICE AND DATA AND | | | ALARM SYSTEMS. | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2013-03-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-01-09 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2013-01-09 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2013-01-09 09:33:15 | FIRE COMMENTS ADDRESSED UNDER PERMIT # 12100670. COPY | | | OF APPROVED FIRE SPRINKLER PLAN ATTACHED TO MASTER | | | PLANS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2013-01-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-04 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-01-04 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2013-01-04 10:42:56 | 801 VILLAGE BOULEVARD - SUITE #303-304 | | | PERMIT #12100670 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: NO ADDRESS PROVIDED IN THE PLAN | | | TITLEBLOCK INFORMATION. | | | | | | REPEAT COMMENT: ENGINEERED FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | | | | REPEAT COMMENT: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS | | | SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER | | | SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE | | | TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR | | | EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN | | | DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT | | | FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION | | | SUCH AS PRE-ENGINEERED SYSTEMS. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-12-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-12-17 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-12-17 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2012-12-17 09:19:42 | 801 VILLAGE BOULEVARD - SUITE #303-304 | | | PERMIT #12100670 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REPEAT COMMENT: NO ADDRESS PROVIDED IN THE PLAN | | | TITLEBLOCK INFORMATION. | | | | | | NEW COMMENT: REVISE THE OCCUPANT LOAD CHART TO MATCH | | | THE OCCUPANT LOADS SHOWN ON THE FLOOR PLAN. | | | ORIGINAL COMMENT: PER TABLE 7.3.1.2 (NFPA 101 - | | | FLORIDA) THE DAY-CARE OCCUPANT LOAD FACTOR SHALL BE 20 | | | SQ.FT. PER PERSON NOT 35 SQ.FT. PER PERSON. | | | | | | REPEAT COMMENT: ELECTRICAL - NO MANUAL FIRE ALARM | | | SYSTEM OR SMOKE DETECTION PROVIDED PER SECTION 16.3.4 | | | (NFPA 101 - FLORIDA). | | | | | | REPEAT COMMENT: ENGINEERED FIRE ALARM AND FIRE | | | SPRINKLER CONSTRUCTION DOCUMENTS ARE REQUIRED FOR A | | | GENERAL BUILDING PERMIT. AFTER THE BUILDING PERMIT HAS | | | BEEN ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT SHOP | | | DRAWINGS (CONFORMING TO THE ENGINEERED CONSTRUCTION | | | DOCUMENTS) FOR A SUB-PERMIT. | | | | | | REPEAT COMMENT: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS | | | SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER | | | SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE | | | TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR | | | EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN | | | DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT | | | FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION | | | SUCH AS PRE-ENGINEERED SYSTEMS. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-10-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-10-29 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-10-29 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2012-10-29 13:18:26 | 801 VILLAGE BOULEVARD - SUITE #303-304 | | | PERMIT #12100670 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION. | | | | | | PLEASE PROVIDE A NOTE ON THE LIFE SAFETY PLAN | | | INDICATING THE FOLLOWING INFORMATION: | | | | | | 1) ARTWORK AND TEACHING MATERIALS ATTACHED TO THE WALLS | | | SHALL NOT EXCEED 50 PERCENT OF THE INDIVIDUAL WALL | | | AREA. | | | | | | 2) AN EMERGENCY PLAN TO BE DEVELOPED AND POSTED IN | | | BUILDING PRIOR TO OCCUPANCY. | | | | | | 3) EMERGENCY EGRESS DRILLS SHALL BE CONDUCTED MONTHLY. | | | ALL DRILLS SHALL BE SOUNDED ON THE FIRE ALARM SYSTEM. | | | | | | 4) FIRE PREVENTION INSPECTIONS SHALL BE CONDUCTED | | | MONTHLY BY A TRAINED SENIOR MEMBER OF THE STAFF, AFTER | | | WHICH A COPY OF THE LATEST INSPECTION REPORT SHALL BE | | | POSTED IN A CONSPICUOUS PLACE IN THE DAY-CARE FACILITY. | | | IT SHALL BE THE DUTY OF THE STAFF TO INSPECT ALL EXITS | | | DAILY TO ENSURE THAT ALL DOORS AND EXIT PATHS ARE | | | MAINTAINED CLEAR OF OBSTRUCTIONS. | | | | | | TRASH AND CONSTRUCTION DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. SMOKING SHALL BE PROHIBITED EXCEPT IN | | | DESIGNATED EXTERIOR AREAS. ALL OTHER DEMOLITION OR | | | CONSTRUCTION AREAS SHALL HAVE "NO SMOKING" SIGNS | | | POSTED. WHERE SMOKING IS PERMITTED, SAFE RECEPTACLES | | | FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING (FAX: 561-804-4774) AND | | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | | 500 NORTH DIXIE HIGHWAY. | | | | | | PER TABLE 7.3.1.2 (NFPA 101 - FLORIDA) THE DAY-CARE | | | OCCUPANT LOAD FACTOR SHALL BE 20 SQ.FT. PER PERSON NOT | | | 35 SQ.FT. PER PERSON. | | | | | | CONFIRM EXISTING DOORS IN LOBBY #101 ARE EQUIPPED WITH | | | PANIC HARDWARE. | | | | | | EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO ALLOW | | | OPENING OF THE LOCKED DOOR FROM THE OUTSIDE BY AN | | | OPENING DEVICE THAT SHALL BE READILY ACCESSIBLE TO THE | | | STAFF. | | | | | | EACH SMOKE OR FIRE-RATED BARRIER SHALL BE PERMANENTLY | | | IDENTIFIED WITH SIGNS OR STENCILING READING FIRE/SMOKE | | | BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT | | | LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH. | | | IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON | | | CENTER. | | | | | | IN BUILDINGS PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED AUTOMATIC SPRINKLER SYSTEM, CORRIDOR WALLS | | | SHALL NOT BE REQUIRED TO BE FIRE RATED PROVIDED THAT | | | SUCH WALLS FORM SMOKE PARTITIONS. | | | | | | SHEET E-2: NO EXIT SIGN AND EMERGENCY LIGHT HAS BEEN | | | PROVIDED FOR THE SECONDARY EXIT DOOR. | | | | | | ELECTRICAL: NO MANUAL FIRE ALARM SYSTEM OR SMOKE | | | DETECTION PROVIDED PER SECTION 16.3.4 (NFPA 101 - | | | FLORIDA). | | | | | | ENGINEERED FIRE ALARM AND FIRE SPRINKLER CONSTRUCTION | | | DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT. | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | WESLEY JOLIN | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-01-09 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2013-01-09 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2013-01-08 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2013-01-08 16:49:42 | TO FIRE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-01-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-04 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-12-21 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2012-12-21 16:17:51 | SENT TO C16 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-19 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-07 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2012-12-10 16:08:23 | EXPEDITED | | | C--16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-12-05 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-10-26 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2012-12-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-28 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-28 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2012-12-28 13:25:25 | IMPACT FEE STAMP - ZERO DUE. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-12-19 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-12-19 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2012-12-19 16:41:00 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-11-14 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-11-14 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2012-11-14 09:42:10 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2012-12-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-12-13 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-12-13 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2012-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-12-05 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-12-05 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2012-12-05 09:59:21 | *** CORRECTIONS NEED TO MECHANICAL PLANS*** | | | | | | 1) MECHANICAL PLAN M1, ROOM #112 HAS EF-1 EXHAUSTION 80 | | | CFM'S FROM THE ROOM, THE A/C DUCT IS ONLY SUPPLYING 75 | | | CFM'S OF AIR TO THE ROOM, THIS WOULD PUT THE ROOM AT A | | | NEGATIVE PRESSURE. THE CLOTHES DRYER MAY NOT BE ABLE TO | | | DISCHARGE TO THE ROOF WHEN THE ROOM IS AT A NEGATIVE | | | PRESSURE. PLEASE PROVIDE DOCUMENTATION FROM THE | | | MANUFACTURE OF THE DRYER SHOWING THE EQUIPMENT CAN | | | OPERATE CORRECTLY UNDER THIS ENVIRONMENT, OR PLEASE | | | CORRECT. SEE 2010 FBC/M 304.1. | | | | | | 2) AHU'S 1, 2, 5, & 7 NEED TO SHOW THE OUTDOOR AIR (FA) | | | IS BEING DUCTED TO THE ROOF, PLEASE CORRECT. SEE 2010 | | | FBC/M 401.4. | | | | | | 3) PLAN M-1 SHOWS A RETURN AIR GRILL IN THE KITCHEN | | | (ROOM 111). PER 2010 FBC/M 407.1 RETURN AIR MAY NOT BE | | | TAKEN FROM A KITCHEN, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY TOM GORDON (HY-BYRD INC.) | | | FOR ASSISTANCE CALL LUIS MARTINEZ (561) 805-6710 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2012-12-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-12-19 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-12-19 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-11-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-11-01 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-11-01 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2012-11-01 10:19:09 | ***PROVISO*** | | | ACCESS REQUIRED FOR WATER HEATER | | | 502.5 CLEARANCES FOR MAINTENANCE AND REPLACEMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2012-10-29 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2012-10-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2012-10-29 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|