Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-11-07 Cont ID  
Sent By shill Date 2012-11-07 Time 15:22 Rev Time 0.00
Received By shill Date 2012-11-07 Time 15:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-30 Cont ID  
Sent By shill Date 2012-10-30 Time 09:52 Rev Time 0.00
Received By shill Date 2012-10-30 Time 09:51 Sent To  
Notes
2012-10-30 10:06:06****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
 ORIGINAL PERMIT DOCUMENTS APPEAR TO SHOW AWNING WINDOWS
 AT TIME OF CONSTRUCTION, WHICH HAVE A REMOVABLE PANEL.
 IT APPEARS THAT REPLACING WITH 38" HIGH SINGLE HUNG
 WINDOWS WILL GREATLY REDUCE THE CLEAR OPENING FOR THE
 BEDROOMS. CASEMENTS OR HORIZONTAL ROLLER WINDOWS ARE
 SUGGESTED.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-30 Cont ID  
Sent By shill Date 2012-10-30 Time 10:39 Rev Time 0.00
Received By shill Date 2012-10-18 Time 09:25 Sent To  
Notes
2012-10-19 09:32:52SENT TO MISC 1 , NO ELECTRICAL, PLUMBING OR MECHANICAL
 PLANS WERE SUBMITTED.