Plan Review Details - Permit 12100439
| Plan Review Stops For Permit 12100439 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2013-03-28 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-03-28 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-12-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-28 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-27 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2012-12-28 16:21:34 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | SEE FBC R 310, FBC 2010 EXISTING BUILDING 604.1. | | | | | | 1. THE 50" HIGH WINDOW IS NOT OF SUFFICIENT HEIGHT FOR | | | EMERGENCY ESCAPE AND RESCUE. PHOTOGRAPHS FROM APRIL | | | 2011 SHOW AWNING WINDOWS. AS AWNING WINDOWS PROVIDE A | | | REMOVABLE PANEL, CLEAR OPENING PREVIOUSLY EXCEEDED THE | | | REQUIREMENT OF 24". THE NEW SINGLE HUNG WINDOW FOR | | | BEDROOM #4, INSTALLED SOMETIME AFTER APRIL 2011, AT 17" | | | CLEAR OPENING HEIGHT DOES NOT MEET THE EMERGENCY ESCAPE | | | AND RESCUE REQUIREMENT. | | | | | | 2. VALUE IS TO INCLUDE ALL MATERIALS AND VALUE OF | | | LABOR, FBC 109.3. | | | | | | PROVIDE A COPY OF THE RECEIPT FOR MATERIALS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-03 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-03 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2012-12-03 18:52:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2ND REVIEW - PLEASE SHOW ROOMS ON THE FLOOR PLAN. THE | | | WINDOWS ARE LABELED AS TO WHAT ROOM THEY SERVE, BUT IT | | | IS NOT CLEAR WHETHER THE 50" HIGH BEDROOM WINDOW IS IN | | | THE SAME ROOM OR A DIFFERENT ROOM THAN THE 60" HIGH | | | BEDROOM WINDOW. | | | | | | ALSO PLEASE PROVIDE INFORMATION REGARDING THE EXISTING | | | WINDOWS (SINGLE HUNG, AWNING, ETC.). | | | | | | 2. VALUE IS TO INCLUDE ALL MATERIALS AND VALUE OF | | | LABOR, FBC 109.3. | | | | | | PROVIDE A COPY OF THE ESTIMATE FOR MATERIALS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-23 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-23 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2012-10-23 13:13:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | 2. VALUE IS TO INCLUDE ALL MATERIALS AND VALUE OF | | | LABOR, FBC 109.3. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2013-03-28 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2013-03-28 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-12-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-28 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-21 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2012-12-21 17:03:24 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-03 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-16 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2012-11-16 16:45:54 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-23 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-16 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2012-10-16 18:08:15 | TO BLDG < $5K |
|
|
|