Plan Review Details - Permit 12100434
Plan Review Stops For Permit 12100434
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-11-16 Cont ID  
Sent By jwitmer Date 2012-11-13 Time 14:06 Rev Time 0.00
Received By jwitmer Date 2012-11-13 Time 14:06 Sent To  
Notes
2012-11-13 14:05:36BUILDING PLAN REVIEW
 PERMIT: 12100434
 ADD: 319 CLEMATIS ST 5 TH FLOOR COMMON CORRIDOR
 CONT: CLAY KOHLMEYER
 TEL: (561)694-1214
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 NOV. 13/ 2012
 ACTION: DENIED
  
  
 1) COMPLIED.
  
 2) SEMI-COMPLIED.
  
 3) SUITE 502 DOOR B, THE CLOUDED REVISION DOES NOT
 INDICATE THE END OF THE INTERIOR WALL DIRECTLY ACROSS
 FROM THE NEW INTERIOR SWING. THE MANEUVERING CLEARANCES
 AS SHOWN IN THE 2010 FBC-B FIGURE 404.2.4.1 MUST BE
 MAINTAINED, PLEASE INDICATE COMPLIANCE WITH MANEUVERING
 CLEARANCES AT MANUAL SWINGING DOORS.
 COMMENT 1ST REVIEW, A-1.0 SUITE 502 DOOR B IS ALSO
 WITHIN 9 INCHES OF A WALL LINE NOT LEAVING A MINIMUM OF
 36" LATCH SIDE OF DOOR AND A MINIMUM CORRIDOR WIDTH OF
 60" AS REQUIRED BY 2010 FBC- ACCESSIBILITY CODE FIGURE
 404.2.4.1 (D).
  
 4) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
 NOV 16/2012 DESIGNER OF RECORD BROUGHT IN NEW
 CORRECTIONS A1 & A2 , PASSED. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-30 Cont ID  
Sent By jwitmer Date 2012-10-30 Time 10:00 Rev Time 0.00
Received By jwitmer Date 2012-10-30 Time 09:50 Sent To  
Notes
2012-10-30 10:28:38BUILDING PLAN REVIEW
 PERMIT: 12100434
 ADD: 319 CLEMATIS ST 5 TH FLOOR COMMON CORRIDOR
 CONT: CLAY KOHLMEYER
 TEL: (561)694-1214
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 OCT. 30/ 2012
 ACTION: DENIED
  
 1) A-1.0 SUITE 502 ENTRY DOOR A IS INDICATED AS A 1
 HOUR RATED DOOR, THE DESIGNER HAS NOT PROVIDED
 INFORMATION ON THE FIRE RATING OF THE SIDELIGHT NEXT TO
 THE DOOR,
 2010 FBC TABLE 715.5 INDICATES THIS TO REQUIRE A 3/4 HR
 RATED OPENING PROTECTIVE. PLEASE NOTE GLAZING WITHIN
 2'-0" OF THE LATCH SIDE OF THE DOOR ALSO REQUIRES
 SAFETY GLAZING PER 2010 FBC-B 2406.4(6). NOTE THE
 DESIGNER HAS DESIGNED THIS OPENING TO A HIGHER STANDARD
 THAN MINIMUM CODE.
  
 2) A-1.0 SUITE 502 DOOR B : 2010 FBC-B 1008.1.9.11
 DURING ITS SWING, ANY DOOR IN A MEANS OF EGRESS SHALL
 LEAVE UNOBSTRUCTED AT LEAST ONE HALF OF THE REQUIRED
 WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY, OR LANDING,
 NOR PROJECT MORE THAN 7 INCHES (178 MM) INTO THE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY OR
 LANDING, WHEN FULLY OPEN.
  
 3) A-1.0 SUITE 502 DOOR B IS ALSO WITHIN 9 INCHES OF A
 WALL LINE NOT LEAVING A MINIMUM OF 36" LATCH SIDE OF
 DOOR AND A MINIMUM CORRIDOR WIDTH OF 60" AS REQUIRED BY
 2010 FBC- ACCESSIBILITY CODE FIGURE 404.2.4.1 (D).
  
 4) SHEET A-2.0 DROPPED SOFFIT DETAIL DOES NOT INDICATE
 WHERE THE RATED WALL WILL CONTINUE TO THE DECK ABOVE,
 NOR THE FLOOR CEILING ASSEMBLY TO WHICH IT IS ATTACHED.
 2010 FBC-B 709.1(6). FIRE PARTITIONS, 712.2 & 3 &
 712.3.1.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-11-19 Cont ID  
Sent By rlecky Date 2012-11-19 Time 12:24 Rev Time 0.00
Received By rlecky Date 2012-11-19 Time 12:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-10-25 Cont ID  
Sent By wjolin Date 2012-10-25 Time 10:51 Rev Time 0.00
Received By wjolin Date 2012-10-25 Time 10:35 Sent To  
Notes
2012-10-25 10:42:12319 CLEMATIS STREET
 PERMIT #12100434
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SUITE #502 HAS A DOOR (LABLED "B") THAT SWINGS INTO THE
 CORRIDOR AN OBSTRUCTS EGRESS. DURING ITS SWING, ANY
 DOOR IN A MEANS OF EGRESS SHALL LEAVE NOT LESS THAN
 ONE-HALF OF THE REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 HALLWAY OR LANDING UNOBSTRUCTED AND SHALL PROJECT NOT
 MORE THAN 7-INCHES INTO THE REQUIRED WIDTH OF THE
 EGRESS PATH WHEN FULLY OPEN.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-11-19 Cont ID  
Sent By rlecky Date 2012-11-19 Time 12:24 Rev Time 0.00
Received By rlecky Date 2012-11-13 Time 14:29 Sent To  
Notes
2012-11-13 14:30:10RESUB FOR A1 AND A2.SENT TO B1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-13 Cont ID  
Sent By rlecky Date 2012-11-13 Time 14:28 Rev Time 0.00
Received By rlecky Date 2012-10-30 Time 08:48 Sent To  
Notes
2012-10-31 08:49:49ARCHITECT'S RESPONSE LETTER WAS SUBMITTED BEFORE
 FINISHING ALL THE REVIEWS. LETTER SENT TO B1 SHELF FOR
 REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-11-19 Cont ID  
Sent By rlecky Date 2012-11-19 Time 12:14 Rev Time 0.00
Received By rlecky Date 2012-10-15 Time 08:54 Sent To  
Notes
2012-10-15 08:55:10INCOMING SENT TO B01. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-10-31 Cont ID  
Sent By hmoser Date 2012-10-31 Time 15:22 Rev Time 0.00
Received By hmoser Date 2012-10-31 Time 14:33 Sent To  
Notes
2012-10-31 15:21:39PROVISO
 REFER TO SECTION 607.7 FLEXIBLE DUCT AND AIR
 CONNECTORS.
 FLEXIBLE DUCT AND CONNECTORS SHALL NOT PASS THROUGH ANY
 FIRE RESISTANCE RATED ASSEMBLY.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-11-13 Cont ID  
Sent By lwagner Date 2012-11-13 Time 14:13 Rev Time 0.00
Received By lwagner Date 2012-11-02 Time 10:40 Sent To  
Notes
2012-11-09 10:35:01****PROVISO****
  
 THE DRINKING FOUNTAIN SPECIFIED ON P-1 (ELKAY EZ4) DOES
 NOT COMPLY WITH FBC ACCESSIBILITY 2010 211.2 NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED:
  
 THE DRINKING FOUNTAIN IS REQUIRED TO BE HI/LOW TYPE OR
 THE EXCEPTION:
 FBC ACCESSIBILITY 2010 211.2 MINIMUM NUMBER. NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6
 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-10-26 Cont ID  
Sent By lwagner Date 2012-10-26 Time 15:06 Rev Time 0.00
Received By lwagner Date 2012-10-18 Time 13:46 Sent To  
Notes
2012-10-18 14:58:34FBC 2010 EXISTING BUILDING CODE
 FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. THE PLUMBING DRAWING IS OK.
  
 2. SHEET A1.0 - THE DRINKING FOUNTAIN IS REQUIRED TO BE
 HI/LOW TYPE OR THE EXCEPTION:
 FBC ACCESSIBILITY 2010 211.2 MINIMUM NUMBER. NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6
 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 3. SHEET A-1.0 - THE RESTROOMS APPEAR NOT TO MEET THE
 ACCESSIBILITY CODE:
 202.3 ALTERATIONS.
 WHERE EXISTING ELEMENTS OR SPACES OR COMMON AREAS ARE
 ALTERED, EACH ALTERED ELEMENT, SPACE OR AREA SHALL
 COMPLY WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 2
 AND SECTION 201.1.1
  
 202.4.1 DISPROPORTIONATE COST.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  