Plan Review Details - Permit 12100382
Plan Review Stops For Permit 12100382
Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-11-19 Cont ID  
Sent By wjolin Date 2012-11-19 Time 11:25 Rev Time 0.00
Received By wjolin Date 2012-11-19 Time 11:05 Sent To M
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-10-15 Cont ID  
Sent By wjolin Date 2012-10-15 Time 10:01 Rev Time 0.00
Received By wjolin Date 2012-10-15 Time 08:23 Sent To M
Notes
2012-10-15 10:01:402101 PALM BEACH LAKES BOULEVARD
 35,000 SQ.FT. CLASS "A" MERCANTILE OCCUPANCY
 PERMIT #12100382
 MASTER #12060374
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE JOB VALUE ($5,400) IS SEVERLY UNDERVALUED. PROVIDE
 A COPY OF THE CONTRACT. JOB VALUE SHALL INCLUDE LABOR
 AND MATERIALS.
  
 THE ENGINEERING CONSTRUCTION DOCUMENTS (SHEET FS2.1)
 ESTABLISH MIRCEA PELLA AS THE ENGINEER OF RECORD FOR
 THE FIRE SPRINKLER DESIGN, THEREFORE, THE SPRINKLER
 SHOP DRAWINGS AND HYDRAULIC CALCULATIONS SHALL NOT BE
 SIGNED/SEALED BY THE CONTRACTOR'S ENGINEER.
  
 THE PLANS DO NOT INDICATE AN AREA REDUCTION FOR QUICK
 RESPONSE SPRINKLERS AND THE PLANS INDICATE A HYDRAULIC
 AREA OF 2,500 SQUARE FEET.; THEREFORE, THE MINIMUM
 LENGTH OF BRANCH LINE CALCULATED SHALL BE AT LEAST 60
 FEET (1.2 X SQUARE ROOT OF 2500). NOTE FYI: THE PLANS
 STATE FACTORY MUTUAL AS THE INSURANCE CARRIER; FM MAY
 REQUIRE A BRANCH LINE LENGTH OF 70 FEET (1.4 X SQUARE
 ROOT OF 2500).
  
 SUBMIT SPRINKLER CUTSHEETS FOR THE 8.0 K-FACTOR
 SPRINKLER TO BE INSTALLED. THE SPRINKLER CUTSHEET
 SUBMITTED WAS FOR A SPRINKLER WITH A K-FACTOR OF 5.6.
  
 IF NOT ALREADY EXISTING, PROVIDE CHAIN WITH LOCK AND
 TAMPER SWITCHES FOR SUPERVISING THE BACKFLOW PREVENTER
 IN THE OPEN POSITION.
  
 PROVIDE LOCKING KNOX CAPS ON FIRE DEPARTMENT
 CONNECTION.
  
 FIRE SPRINKLER SYSTEM SHALL BE MONITORED BY AN APPROVED
 SUPERVISING STATION IN ACCORDANCE WITH NFPA 72.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-12-03 Cont ID  
Sent By lmartine Date 2012-12-03 Time 16:49 Rev Time 0.00
Received By lmartine Date 2012-11-13 Time 15:18 Sent To  
Notes
2012-11-13 15:18:27TO FIRE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-24 Cont ID  
Sent By hmoser Date 2012-10-24 Time 08:31 Rev Time 0.00
Received By hmoser Date 2012-10-11 Time 09:26 Sent To  
Notes
2012-10-12 09:26:46SENT TO FIRE BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-12-03 Cont ID  
Sent By lmartine Date 2012-12-03 Time 16:49 Rev Time 0.00
Received By lmartine Date 2012-12-03 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-10-24 Cont ID  
Sent By hmoser Date 2012-10-24 Time 08:30 Rev Time 0.00
Received By hmoser Date 2012-10-24 Time 07:47 Sent To  
Notes
2012-10-24 08:30:45PLAN DENIED
 VALUE IS TO LOW. VALUE SHALL INCLUDE LABOR AND
 MATERIALS.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]