Plan Review Details - Permit 12100243
| Plan Review Stops For Permit 12100243 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2012-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-03 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-03 |
Time |
18:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-11-13 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-13 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2012-11-13 12:55:02 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FBC 2010 RESIDENTIAL 301.1, RESISTANCE TO WIND LOADS: | | | | | | 1. THE "SHUTTER CONNECTION MOUNTING TYPE" WAS LEFT | | | BLANK. THIS SHOULD BE A CONNECTION TYPE C1 THROUGH C8, | | | SEE ANCHOR CHARTS ON SHEET 4. | | | | | | 2. EDGE DISTANCE CANNOT BE 4" FOR WOOD SUBSTRATE AS YOU | | | WOULD NOT BE FASTENING INTO THE STRUCTURE. | | | | | | 3. ANCHOR SPACING SHOULD BE ONE DIMENSION, DISTANCE | | | (PATTERN) OF ANCHOR SPACING. | | | | | | 4. IT IS ACCEPTABLE TO EXCEED CODE COMPLIANCE, BUT | | | PLEASE BE ADVISED THAT MINIMUM WIND DESIGN REQUIREMENT | | | IS +42.3/-56.6 FOR ZONE 5, 10 SF FOR A 25' HIGH | | | STRUCTURE. IF NO OPENINGS ARE LOCATED IN ZONE 5, ZONE 4 | | | WORST CASE IS +42.3/-45.8. ON THE INSTALLATION | | | SCHEDULE, YOU SPECIFY DESIGN PRESSURES AS +73.2/-81.6, | | | PRODUCT APPROVAL IS FOR DESIGN PRESSURES LESS THAN | | | -75PSF. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-25 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-25 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2012-10-25 18:17:46 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL | | | BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE | | | INSTALLATION SCHEDULE, ITEM 2 ABOVE. FBC R301, FBC1609, | | | FBC*106. | | | | | | 3. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | | | | 4. TWO COMPLETE SETS OF PLANS REQUIRED FOR PERMIT | | | ISSUANCE. FAILURE TO PROVIDE TWO SETS WILL RESULT IN | | | ADMIN/COPY FEES. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-03 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-21 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2012-11-21 08:45:13 | INCOMING SENT TO SAMANTHA'S DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-11-13 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-01 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2012-11-01 15:47:22 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-25 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-09 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2012-10-10 11:10:10 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2012-10-29 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2012-10-15 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2012-10-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
mdekle |
Date |
2012-10-10 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
| 2012-10-15 16:02:41 | APPLICANT MUST PROVIDE FURTHER INFO DEPICTING THE | | | AREA(S) IN WHICH THE PROPOSED SHUTTERS WILL BE | | | INSTALLED. SPOKE WITH CONTRACTOR AND EXPLAINED. HE WILL | | | PROVIDE FURTHER DOCUMENTATION WITH RESUBMITTAL. MD |
|
|
|
Account Summary | Usage Policy | Privacy Policy