Plan Review Details - Permit 12100209
Plan Review Stops For Permit 12100209
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-11-08 Cont ID  
Sent By jwitmer Date 2012-11-08 Time 07:58 Rev Time 0.00
Received By jwitmer Date 2012-11-08 Time 07:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-16 Cont ID  
Sent By jwitmer Date 2012-10-16 Time 13:44 Rev Time 0.00
Received By jwitmer Date 2012-10-16 Time 10:57 Sent To  
Notes
2012-10-16 13:44:48BUILDING PLAN REVIEW
 PERMIT: 12100209
 ADD: 300 CLEMATIS SUITE # 1
 CONT: THE BRIGHTSTORE GROUP
 TEL: (561)889-7206
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 OCT. 16 /2012
 1ST REVIEW
 ACTION: DENIED
  
 1) PLEASE PROVIDE THE TOTAL DISTANCE FROM THE FURTHEST
 POINT IN THE BASEMENT TO THE FRONT DOOR EXIT, FBC-B
 TABLE 1021.2 FOOTNOTE "D" ALLOWS 100 FEET.
 THE MEASUREMENT ALONG STAIRWAYS SHALL BE MADE ON A
 PLANE PARALLEL AND TANGENT TO THE STAIR TREAD NOSING IN
 THE CENTER OF THE STAIRWAY.
  
 2) ONE ISSUE WITH THE SINGLE EXIT AND UNENCLOSED STAIRS
 IS NOTIFICATION IF THERE IS A FIRE ON THE FIRST FLOOR
 (GRADE) AND THE OCCUPANTS IN THE BASEMENT LEVEL NOT
 HAVING NOTIFICATION GIVING THEM TIME TO EXIT THE
 BUILDING. PLEASE PROVIDE SMOKE ALARM ON THE FIRST FLOOR
 (GRADE) LEVEL THAT WILL NOTIFY THE OCCUPANTS IN THE
 BASEMENT IN THE EVENT OF SMOKE/ FIRE. 2010 FBC-B
 907.1.1 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 FOR FIRE ALARM SYSTEMS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE, THE FLORIDA FIRE PREVENTION
 CODE, AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-11-07 Cont ID  
Sent By rlecky Date 2012-11-07 Time 11:46 Rev Time 0.00
Received By rlecky Date 2012-11-07 Time 11:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-10-11 Cont ID  
Sent By rlecky Date 2012-10-11 Time 14:42 Rev Time 0.00
Received By rlecky Date 2012-10-11 Time 14:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2012-11-17 Cont ID  
Sent By wjolin Date 2012-11-17 Time 14:52 Rev Time 0.00
Received By wjolin Date 2012-11-17 Time 14:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-10-11 Cont ID  
Sent By wjolin Date 2012-10-11 Time 14:27 Rev Time 0.00
Received By wjolin Date 2012-10-11 Time 13:54 Sent To  
Notes
2012-10-11 14:27:48300 CLEMATIS STREET - SUITE #1
 PERMIT #12100209
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 PER NFPA 101 SECTION 39.3.1.2 (EXISTING BUSINESS
 OCCUPANCY), "FLOORS THAT ARE BELOW THE STREET FLOOR AND
 ARE USED FOR STORAGE OR OTHER THAN A BUSINESS OCCUPANCY
 SHALL HAVE NO UNPROTECTED OPENINGS TO BUSINESS
 OCCUPANCY FLOORS.
  
 INDICATE THE LOCATION OF THE EXISTING SPRINKLERS SO
 PROPER SPRINKLER COVERAGE CAN BE VERIFIED.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-17 Cont ID  
Sent By wjolin Date 2012-11-17 Time 14:52 Rev Time 0.00
Received By wjolin Date 2012-10-31 Time 10:21 Sent To  
Notes
2012-11-01 10:22:32EXPEDITED
 B--5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-24 Cont ID  
Sent By hmoser Date 2012-10-24 Time 13:57 Rev Time 0.00
Received By hmoser Date 2012-10-05 Time 16:29 Sent To  
Notes
2012-10-09 16:34:13B02

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-11-14 Cont ID  
Sent By hmoser Date 2012-11-14 Time 14:35 Rev Time 0.00
Received By hmoser Date 2012-11-14 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-10-24 Cont ID  
Sent By hmoser Date 2012-10-24 Time 13:57 Rev Time 0.00
Received By hmoser Date 2012-10-24 Time 13:07 Sent To  
Notes
2012-10-24 13:57:06PLANS DENIED
 PLEASE PROVIDE MORE INFORMATION ON THE PLANS
 FOR THE VENTILATION PER SECTION 107 FBC 2010
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-11-05 Cont ID  
Sent By lwagner Date 2012-11-05 Time 10:41 Rev Time 0.00
Received By lwagner Date 2012-11-05 Time 09:22 Sent To  
Notes
2012-11-05 10:43:58REVISION WILL BE REQUIRED IF INSTALLING DRAINAGE OR H
 &C WATER TO THE PEDICURE CHAIRS.

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-10-16 Cont ID  
Sent By lwagner Date 2012-10-16 Time 09:34 Rev Time 0.00
Received By lwagner Date 2012-10-10 Time 13:14 Sent To  
Notes
2012-10-16 09:30:08FBC 2010 EXISTING BUILDING CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. PLEASE INCLUDE HOT AND COLD WATER PIPE IN THE
 PLUMBING DRAWING.
 FBC 2010 LOCAL AMENDMENTS 107.3.5.1.3 (3, 5, 8).
  
 2. PLEASE INCLUDE THE MANUFACTURER INSTALLATION SHEETS
 FOR THE PEDICURE CHAIRS AS THE PLANS SHOW NO DRAINS OR
 PUMP LINES.
 FBC 2010 LOCAL AMENDMENTS 107.2.1.3
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-10-15 Cont ID  
Sent By aaponte Date 2012-10-15 Time 13:50 Rev Time 0.00
Received By aaponte Date 2012-10-15 Time 13:50 Sent To  
Notes
2012-10-15 13:50:57INTERIOR RENOVATION ONLY.