Plan Review Details - Permit 12100190
Plan Review Stops For Permit 12100190
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-10-11 Cont ID  
Sent By jwitmer Date 2012-10-11 Time 11:39 Rev Time 0.00
Received By jwitmer Date 2012-10-11 Time 11:38 Sent To  
Notes
2012-10-11 11:51:00BUILDING PLAN REVIEW
 PERMIT: 12100190/12070789
 ADD: 2615 OKEECHOBEE BLVD
 CONT: BISHOP CONSTRUCTION
 TEL: (561)312-1024
  
 2010 FLORIDA BUILDING CODE W * WEST PALM BEACH
 ADMINISTRATIVE AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) COMPLIED, NEW A2.01 & A6.01 REVISION # 1 DATED
 09/13/2012
  
 2) FIXED BAHAMA SHUTTER IN THE OPEN POSITION NOA
 12-0201.06 WILLARD SHUTTER CO. SHUTTER SUPPLIER SHALL
 PROVIDE ENGINEERING CALCULATIONS FOR SHUTTER TO REMAIN
 OPEN IN HIGH WIND EVENTS AND ANCHOR REQUIREMENTS PER TI
 ARCHITECTURE, INC. FL 61G1-23.015 (2) THE ARCHITECT IS
 RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT
 DATA, REPORTS, SHOP DRAWINGS ETC...
  
 3) SUBMITTED ROOFING APPROVAL: NOA 03-0213.01 JOHN
 MANVILLE BUILT-UP ROOFING SYSTEMS OVER STEEL DECK
 EXPIRED: 07/19/06
 WILL REQUIRE A SEPARATE PERMIT REVIEW AND ASSOCIATED
 FEES.
 ROOFING CONTRACTOR WILL NEED TO CIRCLE WHICH SUB-SYSTEM
 TO BE INSTALLED,
 REVIEW MAXIMUM DESIGN PRESSURES AND IF LIMITATION 7 OR
 9 APPLIES FOR ENHANCED FASTENING!!!!
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-10-09 Cont ID  
Sent By jwitmer Date 2012-10-11 Time 11:51 Rev Time 0.00
Received By rlecky Date 2012-10-09 Time 11:18 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-11 Cont ID  
Sent By rlecky Date 2012-10-09 Time 11:19 Rev Time 0.00
Received By jwitmer Date 2012-10-05 Time 11:12 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-10-11 Cont ID  
Sent By hmoser Date 2012-10-11 Time 09:21 Rev Time 0.00
Received By hmoser Date 2012-10-11 Time 08:55 Sent To B
Notes
2012-10-11 09:25:38PASS PROVISO
 REFER TO SECTION 301.12 WIND RESISTANCE.
 2010 FBC (M) .
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-10-09 Cont ID  
Sent By lwagner Date 2012-10-09 Time 15:45 Rev Time 0.00
Received By lwagner Date 2012-10-09 Time 15:32 Sent To M
Notes
***NONE***