| Plan Review Stops For Permit 12100176 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-08-13 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-08-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-04-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-04-24 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-04-24 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2013-04-24 08:44:03 | SWING ARM MEETS UL 325 SEE PAGE 3. JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-10-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-10-16 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-10-16 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2012-10-16 09:17:53 | BUILDING PLAN REVIEW | | | PERMIT: 12100176 | | | ADD: 4600 PORTOFINO WAY | | | CONT: T. B.D. | | | TEL: (561)###-#### | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) NEW GATE ARMS: NO PRODUCT APPROVALS OR MANUFACTURERS | | | SPECS WERE SUBMITTED WILL NEED TO COMPLY WITH; | | | VEHICULAR GATE. A GATE THAT IS INTENDED FOR USE AT A | | | VEHICULAR ENTRANCE OR EXIT TO A FACILITY, BUILDING OR | | | PORTION THEREOF, AND THAT IS NOT INTENDED FOR USE BY | | | PEDESTRIAN TRAFFIC. | | | | | | 3110.3 VEHICULAR GATES INTENDED FOR AUTOMATION. | | | VEHICULAR GATES INTENDED FOR AUTOMATION SHALL BE | | | DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY WITH THE | | | REQUIREMENTS OF ASTM F 2200. | | | | | | 3110.4 VEHICULAR GATE OPENERS. | | | VEHICULAR GATE OPENERS, WHEN PROVIDED, SHALL BE LISTED | | | IN ACCORDANCE WITH UL 325. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2013-08-06 |
|
|
Cont ID |
|
| Sent By |
rferguso |
Date |
2013-08-06 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rferguso |
Date |
2013-08-06 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2013-08-01 14:17:18 | TO FIRE BOX. JW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-04-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-04-22 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-04-22 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2013-04-22 15:35:03 | 4600 PORTOFINO WAY | | | PERMIT #12100176 & #12100173 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION. | | | | | | CONFIRM 5" MOUNTABLE CURB CAN ACCOMMODATE FIRE | | | APPARATUS WEIGHING AT LEAST 32 TONS. | | | | | | KNOX KEY SWITCH SHALL ACTIVATE BOTH GATES AND ARMS | | | SIMULATANEOUSLY TO PROVIDE THE FIRE DEPARTMENT WITH AN | | | UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND AN | | | UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13 | | | FEET 6 INCHES. | | | | | | SPEED BUMPS ARE NOT PERMITTED BY THE FIRE DEPARTMENT AS | | | EMERGENCY RESPONSE WILL BE DELAYED. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2013-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-08-13 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-08-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-08-09 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-08-09 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-05-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-05-29 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-04-09 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2013-04-11 14:02:25 | SENT TO C10 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-07-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-07-30 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-10-05 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2013-08-09 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-08-09 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-08-09 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-05-18 |
|
|
Cont ID |
|
| Sent By |
mdekle |
Date |
2013-05-18 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-05-18 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2013-04-23 09:41:41 | 4/23/13 |
|
|