Plan Review Details - Permit 12100172
Plan Review Stops For Permit 12100172
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-08-13 Cont ID  
Sent By jwitmer Date 2013-08-13 Time 11:34 Rev Time 0.00
Received By jwitmer Date 2013-08-13 Time 11:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-04-24 Cont ID  
Sent By jwitmer Date 2013-04-24 Time 08:45 Rev Time 0.00
Received By jwitmer Date 2013-04-24 Time 08:44 Sent To  
Notes
2013-04-24 08:55:33SWING ARM COMPLIES WITH UL325. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-15 Cont ID  
Sent By jwitmer Date 2012-10-15 Time 16:45 Rev Time 0.00
Received By jwitmer Date 2012-10-15 Time 16:45 Sent To  
Notes
2012-10-16 09:15:37BUILDING PLAN REVIEW
 PERMIT: 12100172
 ADD: 4400 PORTOFINO WAY
 CONT: T. B.D.
 TEL: (561)###-####
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) NEW GATE ARMS: NO PRODUCT APPROVALS OR MANUFACTURERS
 SPECS WERE SUBMITTED WILL NEED TO COMPLY WITH;
 VEHICULAR GATE. A GATE THAT IS INTENDED FOR USE AT A
 VEHICULAR ENTRANCE OR EXIT TO A FACILITY, BUILDING OR
 PORTION THEREOF, AND THAT IS NOT INTENDED FOR USE BY
 PEDESTRIAN TRAFFIC.
  
 3110.3 VEHICULAR GATES INTENDED FOR AUTOMATION.
 VEHICULAR GATES INTENDED FOR AUTOMATION SHALL BE
 DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY WITH THE
 REQUIREMENTS OF ASTM F 2200.
  
 3110.4 VEHICULAR GATE OPENERS.
 VEHICULAR GATE OPENERS, WHEN PROVIDED, SHALL BE LISTED
 IN ACCORDANCE WITH UL 325.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-08-06 Cont ID  
Sent By rferguso Date 2013-08-06 Time 12:27 Rev Time 0.00
Received By rferguso Date 2013-08-06 Time 12:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-04-22 Cont ID  
Sent By wjolin Date 2013-04-22 Time 15:27 Rev Time 0.00
Received By wjolin Date 2013-04-22 Time 15:11 Sent To  
Notes
2013-04-22 15:27:534400 PORTOFINO WAY
 PERMIT #12100172 & #12100171
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO ADDRESS PROVIDED IN THE PLAN TITLEBLOCK INFORMATION.
  
 CONFIRM 5" MOUNTABLE CURB CAN ACCOMMODATE FIRE
 APPARATUS WEIGHING AT LEAST 32 TONS.
  
 KNOX KEY SWITCH SHALL ACTIVATE BOTH GATES AND ARMS
 SIMULATANEOUSLY TO PROVIDE THE FIRE DEPARTMENT WITH AN
 UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND AN
 UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13
 FEET 6 INCHES.
  
 SPEED BUMPS ARE NOT PERMITTED BY THE FIRE DEPARTMENT AS
 EMERGENCY RESPONSE WILL BE DELAYED.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-08-13 Cont ID  
Sent By shill Date 2013-08-13 Time 11:35 Rev Time 0.00
Received By jwitmer Date 2013-08-01 Time 14:15 Sent To  
Notes
2013-08-07 15:05:448/7 TO ZONING (NEW SHEETS)
  
2013-08-01 14:15:34TO FIRE BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-05-29 Cont ID  
Sent By shill Date 2013-05-29 Time 16:41 Rev Time 0.00
Received By shill Date 2013-04-09 Time 13:59 Sent To  
Notes
2013-04-11 14:00:13SENT TO C10 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-07-30 Cont ID  
Sent By wjolin Date 2013-07-30 Time 11:36 Rev Time 0.00
Received By wjolin Date 2012-10-05 Time 14:09 Sent To  
Notes
2012-10-05 14:10:00C--8

Review Stop Z ZONING
Rev No 3 Status P Date 2013-08-09 Cont ID  
Sent By ajones Date 2013-08-09 Time 13:10 Rev Time 0.00
Received By ajones Date 2013-08-09 Time 08:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2013-05-18 Cont ID  
Sent By ajones Date 2013-05-18 Time 12:58 Rev Time 0.00
Received By ajones Date 2013-05-18 Time 12:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2012-10-16 Cont ID  
Sent By mdekle Date 2012-10-16 Time   Rev Time  
Received By mdekle Date 2012-10-16 Time   Sent To  
Notes
2012-10-16 09:15:04APPROVED PURSUANT TO PB578PP ; LETTER TO APPLICANT FROM
 ANGELLA VANN; DATED JULY 25, 2012.


Account Summary | Usage Policy | Privacy Policy