Plan Review Details - Permit 12100003
Plan Review Stops For Permit 12100003
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-12-10 Cont ID  
Sent By jwitmer Date 2012-12-10 Time 10:53 Rev Time 0.00
Received By jwitmer Date 2012-12-10 Time 10:53 Sent To  
Notes
2012-12-10 10:57:22BUILDING PLAN REVIEW
 PERMIT: 1210003
 ADD: 5329 GEORGIA AVE
 CONT: SCOTT HEMPHILL G C
 TEL: (561)262-8847
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) THE RESTOOMS AS DEPICTED DOES NOT MEET THE 2010 FBC-
 ACCESSIBILITY CODE; NEW CONSTRUCTION SHALL COMPLY WITH
 FIGURE 604.8.1(6).
 ACCESSIBILITY CODE 604.8.1.6 THE WATER CLOSET REQUIRES
 A 60 INCH CLEARANCE, NO OTHER FIXTURES OR OBSTRUCTIONS
 SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET
 CLEARANCE.
  
 NO ROOFING PRODUCT APPROVALS WERE SUBMITTED, TO BE
 UNDER SEPERATE PERMIT, REVIEW WITH ASSOCIATED FEES!!!
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-11-13 Cont ID  
Sent By J WITMER Date 2012-11-13 Time 15:01 Rev Time 0.00
Received By jwitmer Date 2012-11-13 Time 15:01 Sent To  
Notes
2012-11-13 15:08:35BUILDING PLAN REVIEW
 PERMIT: 1210003
 ADD: 5329 GEORGIA AVE
 CONT: SCOTT HEMPHILL G C
 TEL: (561)262-8847
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 REVIEW
 ACTION: DENIED
  
 1-3 COMPLIED.
  
 4)SEMI COMPLIED ONLY ONE SEEET OF APPROVALS SUBMITTED.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS GARAGE DOOR NOA 07-0928.12
 EXPIRED.
 (D) ROOFING PRODUCTS AND ASSEMBLIES THIS CAN BE ISSUED
 UNDER A SEPERATE ROOFING PERMIT.
  
 5) COMPLIED.
  
 NEW COMMENT:
  
 6) SHEET A INDICATES A NEW TENANT SEPERATION WALL,
 WHICH DOES NOT GO TO THE ROOFING DECK ABOVE. PLEASE
 REVIEW :
 2010 FBC-B 709.4 CONTINUITY.
 FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE
 FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE
 UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK
 ABOVE OR TO THE FIRE-RESISTANCE-RATED FLOOR/CEILING OR
 ROOF/CEILING ASSEMBLY ABOVE, AND SHALL BE SECURELY
 ATTACHED THERETO. IF THE PARTITIONS ARE NOT CONTINUOUS
 TO THE SHEATHING, DECK OR SLAB, AND WHERE CONSTRUCTED
 OF COMBUSTIBLE CONSTRUCTION, THE SPACE BETWEEN THE
 CEILING AND THE SHEATHING, DECK OR SLAB ABOVE SHALL BE
 FIREBLOCKED OR DRAFTSTOPPED IN ACCORDANCE WITH SECTIONS
 717.2 AND 717.3 AT THE PARTITION LINE.
  
 7) THE RESTOOMS AS DEPICTED DOES NOT MEET THE 2010 FBC-
 ACCESSIBILITY CODE;
 7A) THE MINIMUM DOOR OPENING IS 32 INCHES CLEAR PLEASE
 REVIEW ACCESSIBILTY 404.2.3.
  
 7B) NEW CONSTRUCTION SHALL COMPLY WITH FIGURE
 604.8.1(6).
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-15 Cont ID  
Sent By jwitmer Date 2012-10-15 Time 13:59 Rev Time 0.00
Received By jwitmer Date 2012-10-12 Time 16:06 Sent To  
Notes
2012-10-12 16:58:02BUILDING PLAN REVIEW
 PERMIT: 12100003
 ADD: 5329 GEORGIA AVE
 CONT: SCOTT W HEMPHILL
 TEL: (561)262-8847
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 OCT.12/2012
 1ST REVIEW
 ACTION: DENIED
  
 1) THE PLANS ARE SIGNED AND SEALED BY RONNIE DIXON PE
 WHY IS THERE A RESIDENTIAL DESIGNER ERVIN KEEL ON A
 ENGINEERS LETTERHEAD ADVERTISING ON A COMMERCAIL
 PROJECT????? F S 471.
  
 2) THIS BUILDING HAS HAD AN EXPLOSION AND EXTREME FIRE
 DAMAGE TO THE STRUCTURE, THE SUBMITTED PLANS DO NOT
 REFLECT THE CONDITION OF THE BUILDING, WHAT ELEMENTS
 ARE DESTROYED, BY FIRE DAMAGE, WHAT ELEMENTS WERE
 DESTORYED BY HEAT, AND FAILURE OCCURED.
 2010 EXISTING BUILDING CODE :
 807.4.1 EVALUATION AND ANALYSIS. AN ENGINEERING
 EVALUATION AND ANALYSIS THAT ESTABLISHES THE STRUCTURAL
 ADEQUACY OF THE ALTERED STRUCTURE SHALL BE PREPARED BY
 A REGISTERED ARCHITECT OR ENGINEER AND SUBMITTED TO THE
 CODE OFFICIAL.
  
 807.4.2 SUBSTANTIAL STRUCTURAL ALTERATION. WHERE MORE
 THAN 30 PERCENT OF THE TOTAL FLOOR AND ROOF AREAS OF
 THE BUILDING OR STRUCTURE HAVE BEEN OR ARE PROPOSED TO
 BE INVOLVED IN STRUCTURAL ALTERATION WITHIN A 12-MONTH
 PERIOD, THE EVALUATION AND ANALYSIS SHALL DEMONSTRATE
 THAT THE ALTERED BUILDING OR STRUCTURE COMPLIES WITH
 THE FLORIDA BUILDING CODE, BUILDING FOR WIND LOADING.
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 5) THE WIND DESIGN CRITERIA INDICATES THIS BUILDING AS
 A IMPORTANCE FACTOR I OR A SHED TYPE BUILDING,
 AGRICULTURAL OUT BUILDING, THE BUILDING CATEGORY IS
 CONSIDERED A II WHICH PUTS IT INTO A WINDZONE OF 170
 MPH, 3 SECOND GUST, THIS WILL ALSO EFFECT THE
 COMPONENTS AND CLADDING PRESSURES.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-12-18 Cont ID  
Sent By rlecky Date 2012-12-18 Time 12:35 Rev Time 0.00
Received By rlecky Date 2012-12-18 Time 12:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-10-11 Cont ID  
Sent By rlecky Date 2012-10-11 Time 13:01 Rev Time 0.00
Received By rlecky Date 2012-10-11 Time 12:51 Sent To  
Notes
2012-10-11 13:01:24SEE NOTES ON PLAN. RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2012-12-08 Cont ID  
Sent By wjolin Date 2012-12-08 Time 19:48 Rev Time 0.00
Received By wjolin Date 2012-12-08 Time 19:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2012-11-17 Cont ID  
Sent By W JOLIN Date 2012-11-17 Time 16:22 Rev Time 0.00
Received By wjolin Date 2012-11-17 Time 16:16 Sent To  
Notes
2012-11-17 16:22:115329 GEORGIA AVENUE
 PERMIT #12100003
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENTS:
  
 NO OCCUPANCY TYPE HAS BEEN INDICATED ON THE PLANS SO
 THE PLANS WILL BE TREATED AS SHELL SPACE ONLY. SEPARATE
 PLANS AND PERMITS MAY BE NEEDED FOR OCCUPANCY BY
 TENANTS.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 PROVIDE EMERGENCY LIGHTS AND EXIT SIGNS.
  
 PROVIDE BUILDING ADDRESS WITH SUITE NUMBERS VISIBLE
 FROM THE STREET. NUMBERS/LETTERS SHALL BE ATTACHED TO
 THE BUILDING AND BE AT LEAST SIX-INCHES IN HEIGHT WITH
 1-INCH STROKE AND SHALL CONTRAST THE BACKGROUND.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 EACH FIRE-RATED BARRIER SHALL BE PERMANENTLY IDENTIFIED
 WITH SIGNS OR STENCILING READING FIRE/SMOKE
 BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT
 LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-10-06 Cont ID  
Sent By wjolin Date 2012-10-06 Time 20:44 Rev Time 0.00
Received By wjolin Date 2012-10-06 Time 20:28 Sent To  
Notes
2012-10-06 20:44:135329 GEORGIA AVENUE
 PERMIT #12100003
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO OCCUPANCY TYPE HAS BEEN INDICATED ON THE PLANS SO
 THE PLANS WILL BE TREATED AS SHELL SPACE ONLY. SEPARATE
 PLANS AND PERMITS MAY BE NEEDED FOR OCCUPANCY BY
 TENANTS.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 PROVIDE EMERGENCY LIGHTS AND EXIT SIGNS.
  
 PROVIDE BUILDING ADDRESS WITH SUITE NUMBERS VISIBLE
 FROM THE STREET. NUMBERS/LETTERS SHALL BE ATTACHED TO
 THE BUILDING AND BE AT LEAST SIX-INCHES IN HEIGHT WITH
 1-INCH STROKE AND SHALL CONTRAST THE BACKGROUND.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 INDICATE WHICH WALLS AROUND THE RESTROOMS ARE INTENDED
 TO BE FIRE RATED.
  
 EACH FIRE-RATED BARRIER SHALL BE PERMANENTLY IDENTIFIED
 WITH SIGNS OR STENCILING READING FIRE/SMOKE
 BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT
 LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-12-19 Cont ID  
Sent By lmartine Date 2012-12-18 Time 09:31 Rev Time 0.00
Received By lmartine Date 2012-12-03 Time 15:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-17 Cont ID  
Sent By wjolin Date 2012-11-17 Time 16:23 Rev Time 0.00
Received By wjolin Date 2012-11-08 Time 09:51 Sent To  
Notes
2012-11-09 10:10:05B11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-24 Cont ID  
Sent By lmartine Date 2012-10-17 Time 12:30 Rev Time 0.00
Received By lmartine Date 2012-10-01 Time 10:50 Sent To  
Notes
2012-10-01 10:50:56SENT TO B11 SHELF FOR REVIEW. JG.

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2012-10-24 Cont ID  
Sent By lmartine Date 2012-10-24 Time 12:30 Rev Time 0.00
Received By lmartine Date 2012-10-24 Time 12:30 Sent To  
Notes
2012-10-24 12:30:44SEE ZONING REVIEW COMMENTS FROM ANGELA.

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-12-17 Cont ID  
Sent By lwagner Date 2012-12-17 Time 10:05 Rev Time 0.00
Received By lwagner Date 2012-12-17 Time 09:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2012-10-10 Cont ID  
Sent By lwagner Date 2012-10-10 Time 10:19 Rev Time 0.00
Received By lwagner Date 2012-10-10 Time 09:53 Sent To  
Notes
2012-10-10 10:20:24NO PLUMBING WORK SHOWN AT THIS TIME.

Review Stop Z ZONING
Rev No 2 Status P Date 2012-12-18 Cont ID  
Sent By ajones Date 2012-12-18 Time 16:43 Rev Time 0.00
Received By ajones Date 2012-12-18 Time 16:43 Sent To  
Notes
2012-12-18 16:45:09PASSED WITH THE PROVISO THAT PRIOR TO THE FIRST
 INSPECTION A LANDSCAPE PLAN MUST BE SUBMITTED AND
 APPROVED. THIS LANDSCAPE PLAN SHOULD SHOW THE PLANTING
 ON LANDSCAPING IN THE PLANTER AREAS ALONG WILMONT
 STREET AND GEORGIA AVENUE. THIS PLAN SHOULD ALSO SHOW
 THE LANDSCAPE BUFFER ALONG THE NORTH PROPERTY LINE IS
 CLEANED UP AND INVASIVE SPECIES ARE REMOVED. STAFF
 NEEDS TO KNOW IF THERE IS ANY LANDSCAPING ALONG THE
 WEST PROPERTY LINE? PLEASE CONTACT ME FOR A MEETING TO
 DISCUSS THE LANDSCAPING ON SITE BEFORE DOING A PLAN.
  
 ANGELLA VANN, PLANNING AND ZONING ADMINSTRATOR
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2012-10-17 Cont ID  
Sent By ajvann Date 2012-10-17 Time 08:59 Rev Time 0.00
Received By ajones Date 2012-10-17 Time 08:59 Sent To  
Notes
2012-10-17 09:08:37PASSED WITH THE PROVISO THAT PRIOR TO THE FIRST
 INSPECTION A LANDSCAPE PLAN MUST BE SUBMITTED AND
 APPROVED. THIS LANDSCAPE PLAN SHOULD SHOW THE PLANTING
 ON LANDSCAPING IN THE PLANTER AREAS ALONG WILMONT
 STREET AND GEORGIA AVENUE. THIS PLAN SHOULD ALSO SHOW
 THE LANDSCAPE BUFFER ALONG THE NORTH PROPERTY LINE IS
 CLEANED UP AND INVASIVE SPECIES ARE REMOVED. STAFF
 NEEDS TO KNOW IF THERE IS ANY LANDSCAPING ALONG THE
 WEST PROPERTY LINE? PLEASE CONTACT ME FOR A MEETING TO
 DISCUSS THE LANDSCAPING ON SITE BEFORE DOING A PLAN.
  
 ANGELLA VANN, PLANNING AND ZONING ADMINSTRATOR
 561-822-1441
 [email protected]


Account Summary | Usage Policy | Privacy Policy