Plan Review Details - Permit 12090541
Plan Review Stops For Permit 12090541
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-01-15 Cont ID  
Sent By jgomez Date 2013-01-15 Time 10:18 Rev Time 0.00
Received By jgomez Date 2013-01-15 Time 10:18 Sent To  
Notes
2013-01-15 10:42:59PER DOUGLAS WISE USE "EVERYTHING IN COMMUNITY PLUS" FOR
 THE 50% RULE OF SUBSTANTIAL IMPROVEMENTS. SEE PDF ON
 THE ATTACHMENTS DEVELOPED BY SAMANTHA HILL TO SHOW ALL
 THE PERMITS ON "COMMUNITY PLUS". ALSO, ATTACHMENT ON
 PERMIT NUMBER 12110428 SHOWS THE IMPROVEMENT APPRAISED
 VALUE OF $300,855 SUBMITTED BY THE OWNER. JG.
  
  
  
  RE: FW: ELEVATION CERTIFICATE, 121 POTTER RD
  
  DOUGLAS WISE
  TO:
  SAMANTHA HILL
  12/10/2012 07:30 PM
  
  
  CC:
  JULIO GOMEZ, LUIS MARTINEZ, ROBERT BROWN, RALPH WALL
  
  
  DON'T USE LIFETIME CUMULATIVE. IT IS AN UNTENABLE
 CRITERIA AND COMPLETELY UNENFORCEABLE.
  
 JUST USE "EVERYTHING IN COMMUNITY PLUS" (FOR NOW).
  
 RALPH AND I ARE IN THE PROCESS OF CHANGING THE
 ORDINANCE TO REFLECT 5 YEARS WHICH IS THE MAXIMUM
 CREDIT YOU CAN GET FROM CRS... OUR CURRENT ORDINANCE
 ALSO CALLS FOR YOU TO ESTABLISH THE VALUE AT SOME POINT
 IN THE PAST WHICH CAN ONLY BE DIVINED BY EXHAUSTIVE
 RESEARCH (THE DATE NOT THE VALUE, SINCE THERE IS NO
 RECOGNIZED METHOD TO ESTABLISH THE VALUE IN THE PAST).
 THIS IS ALSO AN IMPOSSIBLE CRITERIA.
  
 USE "LIFETIME OF THE CURRENT SOFTWARE" AND CALL IT
 QUITS. CRS AND FEMA WILL NOT OBJECT AND OUR CRS RATING
 WILL BE MAINTAINED.
  
 DOUG WISE
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET
 WEST PALM BEACH, FL?? 33402
 PHONE: (561) 805 ? 6650
 FAX: (561) 805 ? 6676
 [email protected]
  
 HOW ARE WE DOING? PLEASE LET US KNOW BY TAKING AN
 ANONYMOUS SURVEY AT: HTTP://WWW.SURVEYMONKEY.COM/WESTPA
 LMBEACHCONSTRUCTIONSERVICES
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-10-31 Cont ID  
Sent By jgomez Date 2012-10-31 Time 14:08 Rev Time 0.00
Received By jgomez Date 2012-10-31 Time 14:08 Sent To  
Notes
2012-10-31 15:45:47RESIDENTIAL (R3) ALTERATION/RENOVATION BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- THIS HOUSE IS LOCATED ON FLOOD ZONE A5. TABLE
 R301.2(1) OF 2010 FBC-RESIDENTIAL AND SEC. 94-546 OF
 CITY CODE REQUIRES NEW CONSTRUCTION OR SUBSTANTIAL
 IMPROVEMENT SHALL HAVE THE LOWEST FLOOR ELEVATED 6
 INCHES ABOVE THE BASE FLOOD ELEVATION. BASE FLOOD
 ELEVATIONS IS 7'-0". THEREFORE THE MIN. FINISH FLOOR
 ELEVATION IS 7'-6". PLEASE PROVIDE SURVEY SHOWING THE
 EXISTING FINISH FLOOR ELEVATION TO VERIFY COMPLIANCE.
 OTHERWISE, HOUSE MAY NEED TO BE RAISED TO COMPLY.
 ELEVATION CERTIFICATE IS REQUIRED ALSO.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON THE SCOPE OF WORK SHOWN ON PLANS.
 VALUATION TO INCLUDE ALL PROFESSIONAL FEES AND
 CONTRACTOR'S OVERHEAD AND PROFIT. PROVIDE COPY OF
 SIGNED CONTRACT. SEC. 109.3 CITY AMENDMENTS TO FBC.
  
 3- ARCHITECT TO PROVIDE THE DESIGN PRESSURES REQUIRED
 BY SEC. R301.2.1.4.3 FOR THE NEW WINDOWS. NOTE:
 ACCORDING TO SEC. R301.2.1.4.3 THIS BUILDING IS LOCATED
 ON EXPOSURE "D". CONSIDER THIS WHEN CALCULATING THE
 DESIGN PRESSURES.
  
 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
2012-10-30 10:43:28BUILDING REVIEW WAS LOCKED. OPENED A NEW STOP TO DO THE
 REVIEW. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-01-10 Cont ID  
Sent By rlecky Date 2013-01-10 Time 11:04 Rev Time 0.00
Received By rlecky Date 2013-01-10 Time 10:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-10-10 Cont ID  
Sent By rlecky Date 2012-10-10 Time 16:29 Rev Time 0.00
Received By rlecky Date 2012-10-10 Time 16:13 Sent To  
Notes
2012-10-10 16:30:5212090541
 121 POTTER ROAD
 SFD RENOVATION
  
 PLEASE PROVIDE THE FOLLOWING:
  
 THE KITCHEN ISLAND COUNTER TOP REQUIRES A GFCI
 PROTECTED RECEPTACLE SERVED FROM A 20 AMPERE SMALL
 APPLIANCE CIRCUIT. NEC 210.52 (C)2
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 THE NEW BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS. NEC 210.12
  
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-15 Cont ID  
Sent By jgomez Date 2013-01-15 Time 16:54 Rev Time 0.00
Received By jgomez Date 2013-01-08 Time 13:40 Sent To  
Notes
2013-01-09 13:42:48SENT TO R1 SHELF FOR ELECTRICAL AND BUILDING REVIEW.
 ALSO, NEED MECHANICAL AND PLUMBING RE-STAMP OF NEW
 PLANS SUBMITTED. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-31 Cont ID  
Sent By jgomez Date 2012-10-31 Time 16:33 Rev Time 0.00
Received By jgomez Date 2012-09-21 Time 16:27 Sent To  
Notes
2012-09-21 16:29:35R--4

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-01-10 Cont ID  
Sent By rmcdouga Date 2013-01-10 Time 14:08 Rev Time 0.00
Received By rmcdouga Date 2013-01-10 Time 14:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-10-18 Cont ID  
Sent By rmcdouga Date 2012-10-18 Time 16:14 Rev Time 0.00
Received By rmcdouga Date 2012-10-18 Time 16:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-01-15 Cont ID  
Sent By jgomez Date 2013-01-15 Time 16:54 Rev Time 0.00
Received By jgomez Date 2013-01-15 Time 16:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-10-23 Cont ID  
Sent By lwagner Date 2012-10-23 Time 14:00 Rev Time 0.00
Received By lwagner Date 2012-10-23 Time 13:47 Sent To  
Notes
***NONE***