Plan Review Details - Permit 12090473
Plan Review Stops For Permit 12090473
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-01-22 Cont ID  
Sent By jgomez Date 2013-01-22 Time 09:08 Rev Time 0.00
Received By jgomez Date 2013-01-22 Time 09:08 Sent To  
Notes
2013-01-22 09:10:26ITEMS SUBMITTED FOR PROVISO DATED 11/1/12. ROOFING
 SHINGLES AND VENTS PRODUCT APPROVALS SUBMITTED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By jgomez Date 2012-11-01 Time 08:49 Rev Time 0.00
Received By jgomez Date 2012-11-01 Time 14:43 Sent To  
Notes
2012-11-01 08:50:52BUILDING REVIEW APPROVED WITH PROVISO AS AGREED WITH
 MICHAEL RETINO OVER THE PHONE ON 11/1/12:
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR ROOF SHINGLES. THERE IS NOT PRODUCT
 APPROVAL ON PACKAGE SUBMITTED.
  
 2- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) PRODUCT APPROVAL AS REQUIRED
 BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 3- REVISED SHEET A-6: THERE ARE DIFFERENT TYPES OF
 NAILS SPECIFIED FOR ROOF SHEATHING. SEC. R803.2.3.1
 REQUIRES MIN. 8D RING SHANK NAILS. REVISE AS REQUIRED
 OR PROVIDE COMPLETE ENGINEERING ANALYSIS SHOWING THAT
 OTHER SPECIFIED NAILS ARE EQUAL OR BETTER THAN 8D RING
 SHANK NAILS. SEC. 107.2.1.3 CITY AMENDMENTS TO FBC.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-09-26 Cont ID  
Sent By jgomez Date 2012-09-26 Time 13:05 Rev Time 0.00
Received By jgomez Date 2012-09-26 Time 08:30 Sent To  
Notes
2012-09-26 13:15:27RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF ASSEMBLY TO BE INSTALLED. AND, CLEARLY
 IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED. PROVIDE THE RAS 117 CALCULATIONS AS REQUIRED
 BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
 NEED CALCULATIONS TO MEET THE DESIGN PRESSURES OF SEC.
 R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL.
  
 ***NOTE: IF GENERAL LIMITATION #7 REQUIRES SIGNED AND
 SEALED RAS 117 CALCULATIONS, THEN, NEED TO PROVIDE
 SIGNED AND SEALED CALCULATIONS.
  
 B) ALL USP STRUCTURAL CONNECTORS SPECIFIED BY THE
 ARCHITECT ON THE PLANS/DETAILS AND SECTIONS.
  
 2- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 3- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT
 IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 4- ARCHITECT'S PLANS AND ENERGY CALCULATIONS NEED TO
 MATCH AND BE COORDINATED. ENERGY CALCULATIONS CALL FOR
 VENTED UNDER ATTIC, WHILE ARCHITECT'S PLANS DON'T SHOW
 ANY VENTILATION. REVISE AS REQUIRED TO MATCH. SEC.
 107.2.1 CITY AMENDMENTS.
  
 5- ARCHITECT TO CLARIFY IF DESIGNING UNVENTED ATTIC.
 SEE SEC. R806.1. AND SEE SEC. R806.4 FOR REQUIRED
 CONDITIONS FOR UNVENTED ATTIC AND REVISE PLANS AS
 REQUIRED TO COMPLY.
 ***NOTE: WALL SECTION 2/8 ON SHEET A-8 SHOWS AIR
 HANDLER UNIT IN DROPPED CEILING. COORDINATE LOCATION OF
 INSULATION TO COMPLY WITH THE VENTED OR UNVENTED ROOF
 AS DESIGNED BY THE ARCHITECT.
  
 6- WALL SECTION 1/7 AND DETAIL 2/10 ON SHEET A-7 SHOW
 RECESSED R-30 INSULATION ON 2X12 ROOF RAFTERS. CLARIFY
 IF ROOF IS BEING DESIGNED AS UNVENTED. SEE ITEM #5
 ABOVE. ALSO, CLARIFY HOW MUCH IS THE INSULATION
 RECESSED. R-30 BUTT INSULATION IS ABOUT 9 1/2" THICK.
 IF THE THICKNESS IS REDUCED THEN THE R-VALUE NEEDS TO
 BE BE REDUCED ACCORDINGLY. AND, IT MAY NOT COMPLY WITH
 THE ENERGY CALCULATIONS. COORDINATE WITH ENERGY
 CALCULATIONS AND REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
 ***NOTE: THIS APPLIES TO NEW BATHROOM FLAT ROOF ALSO.
  
 7- REVISE NAIL TYPE AND SPACING ON ROOF SHEATHING NOTE
 ON SHEET A-10. ROOF SHEATHING TO BE MIN. 8D RING SHANK
 NAILS AND THE SPACING FOR ROOF ZONE #3 IS 4" O.C.. SEE
 SEC. R803.2.3.1 AND REVISE AS REQUIRED.
 ***NOTE: RAS 150 IS NO ADOPTED BY THE CITY OF WEST PALM
 BEACH, THEREFORE CAN'T BE USED.
  
 8- SHEET A-1: REVISE SITE PLAN NOTE L. REMOVE EXISTING
 GARAGE NOT SHED. THIS NEEDS TO BE CLEAR BECAUSE
 DEMOLITION OF A GARAGE VS A SHED HAVE AN IMPACT ON THE
 ZONING REQUIREMENTS. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- SHEET A-3: BATHROOM ADDITION FLOOR FRAMING PLAN.
 PROVIDE SPECIFICATIONS FOR PROTECTION OF THE WOOD
 FRAMING MEMBERS AS REQUIRED BY SEC. R317 OF 2010
 FBC-RESIDENTIAL.
  
 10- PARTITION 42 DETAIL ON SHEET A-5 SPECIFIES "RAFTER
 DESIGNED BY REGISTERED PROFESSIONAL ENGINEER". PROVIDE
 ENGINEER DESIGN. SEC. 107.2.1 CITY AMENDMENTS.
  
 11- REVISE ENERGY CALCULATIONS SUBMITTED. SEC.
 103.2.1.1.1 FBC-ENERGY CONSERVATION.
 A) BATHROOM ADDITION IS NOT ON CONCRETE SLAB. ONLY THE
 GUEST BEDROOM IS. SEE PLANS AND REVISE AS REQUIRED.
 REVISE SQUARE FOOTAGE ACCORDINGLY.
  
 B) REVISE ITEM #10. COORDINATE WITH ARCHITECT TYPE OF
 CEILING. VENTED OR UNVENTED. SEE ITEM #5 ABOVE.
  
 C) COORDINATE ITEM # 13 WITH REVISED A/C EQUIPMENT
 SIZING CALCULATIONS AND A/C PLANS. SEE MECHANICAL
 REVIEW COMMENTS.
  
 D) COMPLETE ALL THE INFORMATION ON TOP OF THE FORM.
 INCLUDING THE BUILDER NAME.
  
 E) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 F) REVISE PAGE 2 OF 5: (1) THERE IS NOT KITCHEN IN THIS
 ADDITION. (2) REVISE FLOOR TYPE AND INSULATION. NEED TO
 CONSIDER THE BATHROOM ADDITION THAT IS NOT ON CONCRETE
 SLAB. (3) TYPE OF ROOF IS NOT HIP ROOF. SEE PLANS AND
 REVISE AS REQUIRED. (4) ATTIC AND CEILING ARE NOT
 VENTED. COORDINATE WITH ARCHITECT AND REVISE AS
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 15:55 Rev Time 0.00
Received By rlecky Date 2012-11-01 Time 15:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-09-25 Cont ID  
Sent By rlecky Date 2012-09-25 Time 08:37 Rev Time 0.00
Received By rlecky Date 2012-09-25 Time 07:00 Sent To  
Notes
2012-09-25 08:37:4412090473
 312 PURITAN ROAD
 SFD REMODEL
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
  
 THE GUEST HOUSE REQUIRES A GROUNDING ELECTRODE. NEC
 250.32
  
 THE ELECTRIC SUBPANEL AT THE GUEST HOUSE MAY NOT BE
 LOCATED IN A CLOSET. PANELS SHALL BE PLACED SO AS TO
 REDUCE TO A MINIMUM THE PROBABILITY OF COMMUNICATING
 FIRE TO ADJACENT COMBUSTIBLE MATERIALS. OVERCURRENT
 DEVICES SHALL NOT BE LOCATED IN THE VICINITY OF EASILY
 IGNITABLE MATERIAL. SUFFICIENT ACCESS AND WORKING SPACE
 IS REQUIRED AT THE SUB PANEL. 36"X 30? IN WIDTH IS THE
 MINIMUM REQUIRED FOR SUB PANELS. NEC 408.17, 240.24
 (D), 110.26 (A)
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 15:59 Rev Time 0.00
Received By rlecky Date 2012-10-26 Time 14:16 Sent To  
Notes
2012-10-26 14:21:10EXPEDITED
 R--20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-09-28 Cont ID  
Sent By mdekle Date 2012-09-28 Time 11:47 Rev Time 0.00
Received By mdekle Date 2012-09-19 Time 16:19 Sent To  
Notes
2012-09-20 16:20:10EXPEDITED
 R--5

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By jgomez Date 2012-11-01 Time 08:56 Rev Time 0.00
Received By jgomez Date 2012-11-01 Time 08:56 Sent To  
Notes
2012-11-01 08:57:50NO FEES. MU 2012-19805. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-09-26 Cont ID  
Sent By jgomez Date 2012-09-26 Time 11:02 Rev Time 0.00
Received By jgomez Date 2012-09-26 Time 11:02 Sent To  
Notes
2012-09-26 11:04:02BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By jgomez Date 2012-11-01 Time 14:11 Rev Time 0.00
Received By jgomez Date 2012-11-01 Time 14:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-09-26 Cont ID  
Sent By jgomez Date 2012-09-26 Time 15:45 Rev Time 0.00
Received By jgomez Date 2012-09-26 Time 15:45 Sent To  
Notes
2012-09-26 15:56:55RESIDENTIAL (R3) ADDITION MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- REVISE EQUIPMENT SIZING CALCULATIONS. SEC. 107.2.1
 CITY AMENDMENTS TO FBC:
 A) THERE ARE TWO DIFFERENT ADDITIONS. ONE IS THE
 BATHROOM ON THE MAIN HOUSE AND THE OTHER ONE IS THE
 SEPARATE INDEPENDENT GUEST BEDROOM/BATHROOM. IT LOOKS
 LIKE THE EQUIPMENT SIZING IS FOR THE GUEST STRUCTURE
 ONLY. THEREFORE, THE AREA TO BE CONSIDERED NEEDS TO BE
 REVISED. IT'S NOT 308 S.F.
  
 B) CLARIFY THE HEATING EQUIPMENT SUMMARY. WHY THE
 HEATING INPUT AND OUTPUT IS 37,658 BTUH. THIS IS NOT
 WHAT IS SHOWN N THE ENERGY CALCULATIONS EITHER.
  
 C) SPECIFY ALL THE EQUIPMENT. SPECIFY THE AIR HANDLER
 UNIT AND THE CONDENSER UNIT..
  
 D) COORDINATE ALL THE INFORMATION WITH THE ENERGY
 CALCULATIONS.
  
 E) COORDINATE AL THE INFORMATION WITH THE EQUIPMENT
 INFORMATION SHOWN ON THE MECHANICAL PLAN M-1. ALL THE
 INFORMATION NEED TO MATCH. EQUIPMENT MODELS, HEATING
 INFORMATION, COOLING INFORMATION, SEER, ELECTRICAL
 REQUIREMENTS, ETC.
  
 F) ARCHITECT TO COORDINATE EQUIPMENT ELECTRICAL
 REQUIREMENTS WITH THE ELECTRICAL PLAN. ELECTRICAL PLAN
 DOESN'T SHOW ELECTRICAL REQUIREMENTS FOR THE AIR
 HANDLER UNIT. REVISE AS REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By jgomez Date 2012-11-01 Time 14:51 Rev Time 0.00
Received By jgomez Date 2012-11-01 Time 14:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-09-26 Cont ID  
Sent By jgomez Date 2012-09-26 Time 11:04 Rev Time 0.00
Received By jgomez Date 2012-09-26 Time 11:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2012-11-01 Time   Rev Time 0.00
Received By   Date 2012-11-01 Time   Sent To  
Notes
2012-11-01 16:24:25 
 PLANNING & ZONING PROVISO:
 ___________________________________________
  
 THE APPLICANT MUST APPLY (AND HAVE APPROVED) A SEPARATE
 LANDSCAPE PERMIT WHICH DEMONSTRATES COMPLIANCE WITH
 SEC. 94-442 OF THE CITY LAND DEVELOPMENT REGULATIONS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME DIRECTLY.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
 WWW.CITYOFWPB.COM
  

Review Stop Z ZONING
Rev No 2 Status F Date 2012-10-29 Cont ID  
Sent By mdekle Date 2012-10-29 Time   Rev Time 0.00
Received By mdekle Date 2012-10-29 Time   Sent To  
Notes
2012-10-29 16:27:13REPEAT COMMENTS:
  
 PLANNING & ZONING: **** FAILED ****
  
 PLEASE RESPOND TO COMMENTS IN WRITING.
  
 PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF THE
 PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2012-09-28 Cont ID  
Sent By mdekle Date 2012-09-28 Time   Rev Time 0.00
Received By mdekle Date 2012-09-28 Time 11:45 Sent To  
Notes
2012-09-28 11:47:02PLANNING & ZONING: **** FAILED ****
  
 PLEASE RESPOND TO COMMENTS IN WRITING.
  
 PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF THE
 PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  