Plan Review Details - Permit 12090272
| Plan Review Stops For Permit 12090272 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2012-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-10-31 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-10-31 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2012-10-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-10-11 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-10-11 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2012-10-11 11:16:01 | THE ROOFING PRODUCT APPROVAL THAT WAS SUBMITTED IS NOA | | | 11-1122.04 FOR GAF ASPHALT SHINGLES. | | | | | | | | | | | 2012-10-11 11:13:55 | REVISIONS ARE REQUIRED FOR THE FOLLOWING PRODUCT | | | APPROVALS. | | | | | | 1) THE SINGLE HUNG WINDOW NOA 09-1008.05 HAS BEEN | | | SUPERSEDED. SUBMIT CURRENT NOA 12-0223.42. | | | | | | 2) THE FL# IS NOT LISTED ON THE PRODUCT APPROVAL | | | SUBMITTED FOR THE JELD-WEN EXTERIOR DOOR WITH REPORT | | | NO. 2035. SUBMIT THE PRODUCT APPROVAL WITH THE FL# FOR | | | THIS DOOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2012-10-31 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-10-31 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-10-31 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2012-09-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-09-24 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-09-24 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2012-09-24 16:52:27 | 12090272 | | | 633 52ND ST. | | | ELECTRIC REPAIR | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | | | ADD RECEPTACLES SO THAT AT NO POINT ALONG THE FLOOR IN | | | ANY WALL IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET | | | AND AT WALL SPACES 2 FEET OR MORE IN WIDTH. NEC 210.52 | | | | | | THE BATHROOMS REQUIRE A DEDICATED 20 AMP BRANCH | | | CIRCUIT. NEC 210.11 (C) (3) | | | | | | BATH #2 REQUIRES A GROUND FAULT PROTECTED RECEPTACLE. | | | NEC 210.52 (D) | | | | | | THE HALL WAY REQUIRES A RECEPTACLE. NEC 210.52 (H) | | | | | | PROVIDE AN ELECTRICAL RISER PLAN AND PANEL SCHEDULE. | | | NEC 215.5 | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-11-01 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-10-25 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2012-10-25 14:06:39 | GAVE TO MCDOUGLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2012-10-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-10-11 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-09-11 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-10-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-10-11 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-10-11 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2012-10-31 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2012-10-31 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2012-10-31 15:52:29 | CHANGE OUT FIXTURES IN THE SAME LOCATIONS. |
|
|
|