| Plan Review Stops For Permit 12090235 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2013-01-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-16 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-16 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2013-01-16 15:13:19 | NOTE (DOES NOT NEED TO BE ADDRESSED) - ROOF NOA | | | REVIEWED - 12-0410.07, JOHNS MANVILLE JM PVC SINGLE PLY | | | ROOF SYSTEM OVER CONCRETE DECKS | | | OK TO ISSUE ROOF SUB PERMIT | | | | | | | | | ***PROVISOS*** | | | | | | SAMANTHA HILL, 561-805-6724, [email protected] | | | | | | | | | FOR THE ROOF EQUIPMENT STAND, FLORIDA STATE OR LOCAL | | | PRODUCT APPROVAL REQUIRED, FAC 9N-3. SUBMIT AS A | | | REVISION PRIOR TO INSTALLATION. | | | | | | REGARDING THE ELEVATION CERTIFICATE, PLEASE REVISE AND | | | SUBMIT PRIOR TO FIRST INSPECTION: | | | | | | ITEM A2, ADDRESS IS INCORRECT. PLEASE REVISE TO 3101 | | | OKEECHOBEE BOULEVARD OR PLEASE CONTACT ME TO DISCUSS | | | THE ADDRESS DISCREPANCY. REVISE BOTH PAGES. | | | | | | ITEM A5. LATITUDE AND LONGITUDE IS TO INCLUDE SECONDS | | | TO 1 DECIMAL PLACE OR BETTER PER INSTRUCTIONS. | | | | | | ITEM A5. WHEN THE LATITUDE AND LONGITUDE ARE PROVIDED | | | BY A SURVEYOR, CHECK THE "YES" BOX IN SECTION D AND | | | INDICATE THE METHOD USED TO DETERMINE THE LATITUDE | | | AND LONGITUDE IN THE COMMENTS AREA OF SECTION D. | | | | | | ITEM C2E, PROVIDE ELEVATION OF MECHANICAL EQUIPMENT | | | WHICH SERVES THE BUILDING AND DESCRIBE TYPE OF | | | EQUIPMENT AND LOCATION IN COMMENTS. IF THE EQUIPMENT IS | | | LOCATED ON THE ROOFTOP, EITHER PROVIDE THE ELEVATION OR | | | NOTE LOCATION IN COMMENTS AREA OF SECTION D. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2013-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-14 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-14 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2013-01-14 17:55:15 | ***CORRECTIONS*** | | | | | | SAMANTHA HILL, 561-805-6724, [email protected] | | | | | | 1. SEE PREVIOUS LISTS. THE DOCUMENT WHICH WAS UPLOADED | | | ON 10/24/12 NAMED LOADENERGYCALCULATIONS IS THE CIVIL | | | COST ESTIMATE. PLEASE PROVIDE ENERGY CALCS PER FBC 2010 | | | ENERGY CONSERVATION 103.2.3. NOTE THAT THIS IS ALSO A | | | STATUTORY REQUIREMENT. | | | | | | 2. PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | FOR THE ROOF EQUIPMENT STAND, FLORIDA STATE OR LOCAL | | | PRODUCT APPROVAL REQUIRED, FAC 9N-3. SUBMIT AS A | | | REVISION PRIOR TO INSTALLATION. | | | | | | REGARDING THE ELEVATION CERTIFICATE, PLEASE REVISE AND | | | SUBMIT PRIOR TO FIRST INSPECTION: | | | | | | ITEM A2, ADDRESS IS INCORRECT. PLEASE REVISE TO 3101 | | | OKEECHOBEE BOULEVARD OR PLEASE CONTACT ME TO DISCUSS | | | THE ADDRESS DISCREPANCY. REVISE BOTH PAGES. | | | | | | ITEM A5. LATITUDE AND LONGITUDE IS TO INCLUDE SECONDS | | | TO 1 DECIMAL PLACE OR BETTER PER INSTRUCTIONS. | | | | | | ITEM A5. WHEN THE LATITUDE AND LONGITUDE ARE PROVIDED | | | BY A SURVEYOR, CHECK THE "YES" BOX IN SECTION D AND | | | INDICATE THE METHOD USED TO DETERMINE THE LATITUDE | | | AND LONGITUDE IN THE COMMENTS AREA OF SECTION D. | | | | | | ITEM C2E, PROVIDE ELEVATION OF MECHANICAL EQUIPMENT | | | WHICH SERVES THE BUILDING AND DESCRIBE TYPE OF | | | EQUIPMENT AND LOCATION IN COMMENTS. IF THE EQUIPMENT IS | | | LOCATED ON THE ROOFTOP, EITHER PROVIDE THE ELEVATION OR | | | NOTE LOCATION IN COMMENTS AREA OF SECTION D. | | | | | | 3. NOTE (DOES NOT NEED TO BE ADDRESSED) - ROOF NOA | | | REVIEWED - 12-0410.07, JOHNS MANVILLE JM PVC SINGLE PLY | | | ROOF SYSTEM OVER CONCRETE DECKS | | | OK TO ISSUE ROOF SUB PERMIT | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-10 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-12-10 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2012-12-10 11:26:55 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. THIS PARCEL IS LOCATED IN SPECIAL HAZARD FLOOD ZONE | | | A8. WPB MUNICIPAL CODE 94 546(B), ALL NEW IMPROVEMENTS | | | TO COMPLY WITH REQUIREMENTS FOR NEW CONSTRUCTION. | | | FINISHED FLOOR SLAB TO BE AT A MINIMUM OF 16.5 FT. THE | | | GRADING PLAN AND OTHER SHEETS SHOW A BUILDING ELEVATION | | | OF 20.40 FT. PROPOSED CONSTRUCTION APPEARS TO COMPLY; | | | PLEASE PROVIDE A SIGNED AND SEALED ELEVATION | | | CERTIFICATE (CONSTRUCTION DRAWINGS). AN ADDITIONAL | | | ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO C.O. | | | (FINAL CONSTRUCTION). THE ELEVATION CERTIFICATE CAN BE | | | EITHER THE FEMA 2009 ELEVATION CERTIFICATE FORM (OMB | | | NO. 1660-0008, EXPIRES MARCH 31, 2012) OR ON THE NEW | | | FORM WHICH WILL BE AVAILABLE NEXT WEEK ON THE FEMA | | | WEBSITE. THERE WILL BE A ONE YEAR PHASE IN PERIOD | | | DURING WHICH THE NEW FORM WILL BE VOLUNTARY. | | | | | | 2ND REVIEW, PLEASE PROVIDE ELEVATION CERTIFICATE | | | (CONSTRUCTION DRAWINGS) AS REQUESTED. INFORMATION SUCH | | | AS PROPOSED ELEVATION, MECHANICAL EQUIPMENT ELEVATION, | | | AND OTHER ITEMS WILL BE REVIEWED. | | | | | | 2. LS 1.0, ARRANGEMENTS OF EXITS, SEE FBC 1015.2.1, | | | EXIT DOORS TO BE PLACED A DISTANCE APART EQUAL TO NOT | | | LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL | | | DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED | | | (ONE THIRD DISTANCE IF BUILDING IS SPRINKLERED, SEE | | | EXCEPTION). | | | | | | PLEASE REVISE NOTE (WHICH STATES 1/3 DIAGONAL) AND | | | DIMENSIONS AS REQUIRED. | | | | | | 3. OK. | | | | | | 4. LS 1.0, TRAVEL DISTANCE OF 114 FT 4 IN SHOWN FROM | | | ONE CORNER TO OPPOSITE EXIT. PLEASE ALSO SHOW COMMON | | | PATH AS IT APPEARS TO EXCEED 75 FEET, FBC 1014.3. | | | | | | 2ND REVIEW, PLEASE REVISE TO SHOW COMMON PATH AS | | | DEFINED BY FBC 1002: | | | | | | "THAT PORTION OF EXIT ACCESS WHICH THE OCCUPANTS ARE | | | REQUIRED TO TRAVERSE BEFORE TWO SEPARATE AND DISTINCT | | | PATHS OF EGRESS TRAVEL TO TWO EXITS ARE AVAILABLE" (NOT | | | VISIBLE AS STATED ON PLAN). PLEASE CONTACT ME IF YOU | | | WISH TO DISCUSS. | | | | | | 5. OK | | | | | | 6. NOTE THE FOLLOWING REGARDING PRODUCT APPROVALS | | | FAC9N-3, FBC 1609: | | | | | | AC STAND - IF MANUFACTURED ONSITE, PROVIDE A DETAIL. IF | | | MANUFACTURED OFF SITE, FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED | | | | | | ALUMINUM IMPACT BI PARTING CAR DOOR SYSTEM - PROVIDE | | | PRODUCT APPROVAL TO VERIFY DESIGN PRESSURES, IMPACT, | | | AND METHOD OF INSTALLATION. THIS MAY HAVE BEEN PROVIDED | | | TO YOU WITH THE RECORDS RESEARCH REQUEST INFORMATION. | | | | | | PAIR 4X8 IMPACT STOREFRONT DOOR SYSTEM (DOOR A) - OK | | | | | | WINDOW WALL SYSTEM WITH DOOR (DOOR B) - OK | | | | | | IMPACT SINGLE DOOR (DOOR C) - OK | | | | | | ROOF - ULTRAGARD PVC SR 50 - THE ASSEMBLY SELECTED IS | | | FOR WOOD DECK, PLAN SHOWS DOUBLE TEES. ENGINEERING | | | REQUIRED FOR ZONES 2 AND 3 IF ASSEMBLY DESIGN PRESSURE | | | DOES NOT MEET MINIMUMS SPECIFIED BY ENGINEER. | | | | | | NEW EIFS WALL SYSTEM - OK | | | | | | BUTT GLAZED WINDOW WALL SYSTEM (PRODUCT APPROVAL OR | | | TEST REPORT AS PER A 5.0) - OK | | | | | | ANY INFORMATION NOT SUBMITTED PRIOR TO PERMIT ISSUANCE | | | WILL BE REQUIRED TO BE SUBMITTED AS A REVISION. DESIGN | | | PRESSURES TO MEET REQUIREMENTS ON S 7.1. | | | | | | 7. OK. | | | | | | 8. PLEASE PROVIDE THE ENERGY CALCS. THE DOCUMENT WHICH | | | WAS UPLOADED WHICH IS NAMED LOADENERGYCALCULATIONS.PDF | | | IS THE SAME DOCUMENT AS THE CIVIL COST ESTIMATE. SEE | | | FBC 2010 ENERGY 103.2.3. | | | | | | 9. OK. | | | | | | 10. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY | | | REQUIRED. PLEASE CONTACT 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-25 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-25 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2012-10-25 16:27:44 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. THIS PARCEL IS LOCATED IN SPECIAL HAZARD FLOOD ZONE | | | A8. WPB MUNICIPAL CODE 94 546(B), ALL NEW IMPROVEMENTS | | | TO COMPLY WITH REQUIREMENTS FOR NEW CONSTRUCTION. | | | FINISHED FLOOR SLAB TO BE AT A MINIMUM OF 16.5 FT. THE | | | GRADING PLAN AND OTHER SHEETS SHOW A BUILDING ELEVATION | | | OF 20.40 FT. PROPOSED CONSTRUCTION APPEARS TO COMPLY; | | | PLEASE PROVIDE A SIGNED AND SEALED ELEVATION | | | CERTIFICATE (CONSTRUCTION DRAWINGS). AN ADDITIONAL | | | ELEVATION CERTIFICATE WILL BE REQUIRED PRIOR TO C.O. | | | (FINAL CONSTRUCTION). THE ELEVATION CERTIFICATE CAN BE | | | EITHER THE FEMA 2009 ELEVATION CERTIFICATE FORM (OMB | | | NO. 1660-0008, EXPIRES MARCH 31, 2012) OR ON THE NEW | | | FORM WHICH WILL BE AVAILABLE NEXT WEEK ON THE FEMA | | | WEBSITE. THERE WILL BE A ONE YEAR PHASE IN PERIOD | | | DURING WHICH THE NEW FORM WILL BE VOLUNTARY. | | | | | | 2. LS 1.0, ARRANGEMENTS OF EXITS, SEE FBC 1015.2.1, | | | EXIT DOORS TO BE PLACED A DISTANCE APART EQUAL TO NOT | | | LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL | | | DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED | | | (ONE THIRD DISTANCE IF BUILDING IS SPRINKLERED, SEE | | | EXCEPTION). IT APPEARS THAT ITEMS 2 AND 4 WOULD BE | | | RESOLVED BY INCLUDING THE ADDITIONAL DOUBLE DOOR AS AN | | | EXIT, NOT CLEAR WHY THIS WAS EXCLUDED FROM LS PLAN AS | | | AN EXIT. | | | | | | 3. LS 1.0, THE HALLWAY TO THE BATHROOMS APPEARS TO BE A | | | DEAD END, PLEASE PROVIDE DIMENSION ON THE LS PLAN. | | | | | | 4. LS 1.0, TRAVEL DISTANCE OF 114 FT 4 IN SHOWN FROM | | | ONE CORNER TO OPPOSITE EXIT. PLEASE ALSO SHOW COMMON | | | PATH AS IT APPEARS TO EXCEED 75 FEET, FBC 1014.3. | | | | | | 5. SECTION 2 A 4.0 AND OTHER DETAILS SHOW A WOOD TRUSS. | | | PLEASE CLARIFY AND CONFIRM TYPE II B BUILDING TYPE OR | | | REVISE ACCORDINGLY. | | | | | | 6. NEED PRODUCT APPROVALS FOR: | | | | | | AC STAND | | | ALUMINUM IMPACT BI PARTING CAR DOOR SYSTEM | | | PAIR 4X8 IMPACT STOREFRONT DOOR SYSTEM (DOOR A) | | | WINDOW WALL SYSTEM WITH DOOR (DOOR B) | | | IMPACT SINGLE DOOR (DOOR C) | | | ROOF - ULTRAGARD PVC SR 50 | | | NEW EIFS WALL SYSTEM | | | BUTT GLAZED WINDOW WALL SYSTEM (PRODUCT APPROVAL OR | | | TEST REPORT AS PER A 5.0) | | | | | | ANY INFORMATION NOT SUBMITTED PRIOR TO PERMIT ISSUANCE | | | WILL BE REQUIRED TO BE SUBMITTED AS A REVISION. DESIGN | | | PRESSURES TO MEET REQUIREMENTS ON S 7.1. | | | | | | 7. INTERIOR WALL AND CEILING FINISH TO COMPLY WITH FBC | | | 803 (SEE ALSO 803.2). PROVIDE INFORMATION FOR THE WOOD | | | GRAIN PLASTIC LAMINATE VENEER AS WELL AS METHOD OF | | | ATTACHMENT, FBC 803.10. | | | | | | 8. PLEASE PROVIDE THE ENERGY CALCS. THE DOCUMENT WHICH | | | WAS UPLOADED WHICH IS NAMED LOADENERGYCALCULATIONS.PDF | | | IS THE SAME DOCUMENT AS THE CIVIL COST ESTIMATE. SEE | | | FBC 2010 ENERGY 103.2.3. | | | | | | 9. OCCUPANCY CLASSIFICATION IS SHOWN AS BUSINESS; | | | PLEASE INCLUDE THE PARTS AREA IN THE OCCUPANCY AS THIS | | | BUILDING APPEARS TO BE MIXED USE. SEE FBC 508 REGARDING | | | MIXED USE BUILDINGS, OCCUPANCY SEPARATIONS, AND | | | NONSEPARATED OCCUPANCIES. | | | | | | 10. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY | | | REQUIRED. PLEASE CONTACT 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-10-25 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-10-25 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2012-10-31 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-10-31 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
2012-10-31 |
Time |
|
Sent To |
Z |
|
| Notes |
| 2012-10-31 16:14:13 | PASSED WITH PROVISO: | | | | | | PROVIDE CHANGES AS PER CITY OF WPB PLANNING COMMENTS. | | | | | | EVEN THOUGH THE SITE DRAINAGE ELEMENTS ARE VERTY SMALL | | | SCALE THE PROJECT WILL BE REQUIRED TO COMPLY WITH | | | POLLUTION PREVENTION AND PROVIDE BMP'S DURING | | | CONSTRUCTION. | | | FOR ASSISTANCE PLEASE REFER TO: | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2013-01-23 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-17 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-01-17 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2013-01-17 10:23:44 | 3101 OKEECHOBEE BOULEVARD | | | PERMIT #12090235 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO - SUBMIT REVISION***** | | | | | | RESPONSE COMMENT: | | | THE LIFE SAFETY CODE REQUIRES EACH OCCUPANCY CHAPTER TO | | | BE REVIEWED INDEPENDENTLY WITH THE MOST RESTRICTIVE | | | REQUIREMENTS APPLYING WHEN THE SPACE IS MIXED USE. IN | | | THIS CASE, THE MOST RESTRICTIVE REQUIREMENT IS A HAZARD | | | SEPARATION BETWEEN THE STORAGE AND BUSINESS AREAS. | | | | | | 6.1.14.3 MIXED OCCUPANCIES. | | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | | CLASSIFIED AS TO ITS USE IN ACCORDANCE WITH SECTION | | | 6.1. | | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | | RESTRICTIVE REQUIREMENTS OF THE OCCUPANCIES INVOLVED, | | | UNLESS SEPARATE SAFEGUARDS ARE APPROVED. | | | | | | ORIGINAL COMMENT:THERE DOES NOT APPEAR TO BE AN | | | EXISTING FIRE BARRIER SEPARATING THE PARTS AREA | | | (STORAGE OCCUPANCY) FROM THE BUSINESS OCCUPANCY. | | | PROVIDE A FIRE BARRIER. ALL OPENINGS AND PENETRATIONS | | | TO BE PROTECTED. | | | | | | ADDITIONAL INFORMATION: NFPA 101 SECTION 39.3.2 - | | | PROTECTION FROM HAZARDS: "HAZARDOUS AREAS INCLUDING, | | | BUT NOT LIMITED TO, AREAS USED FOR GENERAL | | | STORAGE...SHALL BE PROTECTED IN ACCORDANCE WITH SECTION | | | 8.7." | | | | | | NFPA 101 SECTION 8.7.1.1 "PROTECTION FROM ANY AREA | | | HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO | | | THE GENERAL OCCUPANCY OF THE BUILDING OR STRUCTURE | | | SHALL BE PROVIDED BY ONE OF THE FOLLOWING MEANS: | | | (1) ENCLOSING THE AREA WITH A FIRE BARRIER WITHOUT | | | WINDOWS THAT HAS A 1-HOUR FIRE RESISTANCE RATING IN | | | ACCORDANCE WITH SECTION 8.3 | | | (2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING | | | SYSTEMS IN ACCORDANCE WITH SECTION 9.7 | | | (3) APPLYING BOTH 8.7.1.1(1) AND (2) WHERE THE HAZARD | | | IS SEVERE OR WHERE OTHERWISE SPECIFIED BY CHAPTERS 11 | | | THROUGH 43" | | | | | | WESLEY JOLIN | | | WPB FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 805 - 6730 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-12-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-12-04 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-12-04 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2012-12-04 11:40:52 | 3101 OKEECHOBEE BOULEVARD | | | PERMIT #12090235 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ORIGINAL COMMENT:THERE DOES NOT APPEAR TO BE AN | | | EXISTING FIRE BARRIER SEPARATING THE PARTS AREA | | | (STORAGE OCCUPANCY) FROM THE BUSINESS OCCUPANCY. | | | PROVIDE A FIRE BARRIER. ALL OPENINGS AND PENETRATIONS | | | TO BE PROTECTED. | | | | | | ADDITIONAL INFORMATION: NFPA 101 SECTION 39.3.2 - | | | PROTECTION FROM HAZARDS: "HAZARDOUS AREAS INCLUDING, | | | BUT NOT LIMITED TO, AREAS USED FOR GENERAL | | | STORAGE...SHALL BE PROTECTED IN ACCORDANCE WITH SECTION | | | 8.7." | | | | | | NFPA 101 SECTION 8.7.1.1 "PROTECTION FROM ANY AREA | | | HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO | | | THE GENERAL OCCUPANCY OF THE BUILDING OR STRUCTURE | | | SHALL BE PROVIDED BY ONE OF THE FOLLOWING MEANS: | | | (1) ENCLOSING THE AREA WITH A FIRE BARRIER WITHOUT | | | WINDOWS THAT HAS A 1-HOUR FIRE RESISTANCE RATING IN | | | ACCORDANCE WITH SECTION 8.3 | | | (2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING | | | SYSTEMS IN ACCORDANCE WITH SECTION 9.7 | | | (3) APPLYING BOTH 8.7.1.1(1) AND (2) WHERE THE HAZARD | | | IS SEVERE OR WHERE OTHERWISE SPECIFIED BY CHAPTERS 11 | | | THROUGH 43" | | | | | | WESLEY JOLIN | | | WPB FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 805 - 6730 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-10-25 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-10-25 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2012-10-25 09:18:05 | 3101 OKEECHOBEE BOULEVARD | | | PERMIT #12090235 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THERE DOES NOT APPEAR TO BE AN EXISTING FIRE BARRIER | | | SEPARATING THE PARTS AREA (STORAGE OCCUPANCY) FROM THE | | | BUSINESS OCCUPANCY. PROVIDE A FIRE BARRIER. ALL | | | OPENINGS AND PENETRATIONS TO BE PROTECTED. | | | | | | PROVIDE AN EXIT SIGN AT THE MAIN ENTRANCE, OTHERWISE | | | THE COMMON PATH OF TRAVEL EXCEEDS 75 FEET. | | | | | | WESLEY JOLIN | | | WPB FIRE RESCUE | | | OFFICE OF THE FIRE MARSHAL | | | (561) 805 - 6730 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-01-23 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-01-23 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-01-09 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2012-12-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-12-10 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-11-29 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-11-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2012-09-17 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2012-10-24 15:15:55 | DIGITAL |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2013-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-01-14 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-01-14 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2013-01-14 15:15:18 | MU-2012-022883-0000 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-10-25 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-10-25 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2012-10-25 16:45:27 | IMPACT FEES DUE (ENCLOSING AREA UNDER EXISTING ROOF) | | | 561-233-5025 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2012-10-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2012-10-24 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2012-10-24 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2012-10-24 15:24:10 | PROVISO: | | | | | | SUBMIT PRODUCT APPROVAL FOR PRE-ENGINEERED A/C STAND | | | PRIOR TO INSTALLATION AND INSPECTION PER FBC-B 106.1 | | | AND FAC RULE 9N-3. | | | | | | RJR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2012-10-25 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-10-25 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-10-25 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2013-01-31 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2013-01-31 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-01-31 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2012-11-01 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2012-11-01 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2012-11-01 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|