Plan Review Details - Permit 12090027
Plan Review Stops For Permit 12090027
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-10-23 Cont ID  
Sent By jgomez Date 2012-10-22 Time 17:52 Rev Time 0.00
Received By jgomez Date 2012-10-22 Time 17:52 Sent To  
Notes
2012-10-22 17:56:45BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR: ENTRY DOOR SIZE AS SPECIFIED ON
 PLANS.
 2- ARCHITECT OF RECORD TO REVIEW AND APPROVE ENTRY DOOR
 PRODUCT APPROVAL. SEC. 107.3.4.1 CITY AMENDMENTS TO
 FBC.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-03 Cont ID  
Sent By jgomez Date 2012-10-03 Time 12:59 Rev Time 0.00
Received By jgomez Date 2012-10-03 Time 08:51 Sent To  
Notes
2012-10-03 13:01:25NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF. AND: CLEARLY IDENTIFY APPROVED ASSEMBLY
 TO BE INSTALLED. PROVIDE RAS 117 CALCULATIONS AS
 REQUIRED BY GENERAL LIMITATION #7 TO MEET THE DESIGN
 PRESSURES REQUIRED BY SEC. R301.2.1.4.3 OF 2010
 FBC-RESIDENTIAL. IF GENERAL LIMITATION REQUIRES THOSE
 CALCULATIONS TO BE SIGNED AND SEALED, THEN, PROVIDE
 SIGNED AND SEALED RAS 117 CALCULATIONS.
  
 B) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 C) WINDOW MULLIONS AS SHOWN ON PLANS.
  
 D) ENTRY DOOR WITH SIDELITES AND TRANSOM ABOVE AS SHOWN
 ON PLANS.
  
 E) 2'-8" X 7'-0" SINGLE CASEMENT WINDOW AS SHOWN ON
 PLANS. PRODUCT APPROVAL SUBMITTED DOESN'T INCLUDE THIS
 WINDOW SIZE.
  
 F) DOUBLE FRENCH DOORS WITH SIDELITES AS SHOWN ON
 PLANS.
  
 G) SINGLE AND DOUBLE FRENCH DOORS AS SHOWN ON PLANS.
 NOA 08-0821.09 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE.
 VISIT THE MIAMI-DADE WEBSITE AND DOWNLOAD CURRENT NOA.
 RESUBMIT.
  
 H) GARAGE DOOR THAT MEETS THE DESIGN PRESSURES
 CALCULATED BY THE ARCHITECT ON SHEET A-3.
  
 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 4- PROVIDE 2 COPIES OF SOIL TEST REPORT. ONLY ONE COPY
 WAS SUBMITTED. SEC. 107.3.1 CITY AMENDMENTS.
  
 5- VERIFY/CLARIFY IF ATTIC ACCESS SHOWN ON "SAM'S
 CLOSET" AND ON "HIS CLOSET" COMPLY WITH THE HEADROOM
 REQUIREMENTS OF SEC. R807.
  
 6- SHEET A-4:
 A) REVISE ROOF SHEATHING "NAILING PATTERN SCHEDULE"..
 ACCORDING TO SEC. R803.2.3.1 THE MIN. TYPE OF NAIL TO
 BE USED IS 8D RING SHANK NAILS. THIS INCLUDE ROOF ZONES
 2 AND 3. REVISE AS REQUIRED.
  
 B) REVISE "ROOF COMPONENTS AND CLADDING PRESSURES".
 THEY DON'T CORRESPOND TO EXPOSURE "D". SEE TABLE
 R301.2(2) INCLUDING ALL THE FOOTNOTES.
 NOTE: REMEMBER THAT TABLE R301.2(2) IS FOR EXPOSURE
 "B". AND, THE DESIGN PRESSURES FOR CORNER AND PERIMETER
 AREAS ARE HIGHER BECAUSE OF THE ROOF PITCH (3 1/2 SHOWN
 ON ELEVATIONS).
  
 7- PROVIDE MANUFACTURER'S SPECS FOR THE ICYNENE TO BE
 USED AND THE 1" RIGID INSULATION TO VERIFY COMPLIANCE
 WITH THE ENERGY CALCULATIONS REQUIREMENTS AND SEC.
 R316.
  
 8- PROVIDE DRAINAGE PLANS SHOWING COMPLIANCE WITH SEC.
 R401.3. WATER CAN'T BE DIVERTED TO NEIGHBORS PROPERTY
 EITHER.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-10-23 Cont ID  
Sent By rlecky Date 2012-10-23 Time 17:22 Rev Time 0.00
Received By rlecky Date 2012-10-23 Time 16:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-09-06 Cont ID  
Sent By rlecky Date 2012-09-06 Time 16:00 Rev Time 0.00
Received By rlecky Date 2012-09-06 Time 09:52 Sent To  
Notes
2012-09-06 15:59:56THE FOLLOWING INFORMATION HAS BEEN APPLIED TO THE PLAN.
  
 ADD RECEPTACLES SO THAT AT NO POINT ALONG THE FLOOR IN
 ANY WALL IS MORE THAN 6 FEET FROM A RECEPTACLE OUTLET
 AND AT WALL SPACES 2 FEET OR MORE IN WIDTH. NEC 210.52
 THE BATHROOMS REQUIRE A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2012-10-24 Cont ID  
Sent By lwagner Date 2012-10-24 Time 09:11 Rev Time 0.00
Received By lwagner Date 2012-10-24 Time 09:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2012-10-04 Cont ID  
Sent By lwagner Date 2012-10-04 Time 10:08 Rev Time 0.00
Received By lwagner Date 2012-10-04 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-24 Cont ID  
Sent By lwagner Date 2012-10-24 Time 09:11 Rev Time 0.00
Received By lwagner Date 2012-10-15 Time 15:53 Sent To  
Notes
2012-10-16 16:16:21IN ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-04 Cont ID  
Sent By lwagner Date 2012-10-04 Time 10:09 Rev Time 0.00
Received By lwagner Date 2012-09-04 Time 11:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-10-22 Cont ID  
Sent By jgomez Date 2012-10-22 Time 17:56 Rev Time 0.00
Received By jgomez Date 2012-10-22 Time 17:56 Sent To  
Notes
2012-10-22 17:57:44MU-2012-018527. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-10-03 Cont ID  
Sent By jgomez Date 2012-10-03 Time 09:48 Rev Time 0.00
Received By jgomez Date 2012-10-03 Time 09:48 Sent To  
Notes
2012-10-03 09:49:46BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-10-23 Cont ID  
Sent By jgomez Date 2012-10-23 Time 14:34 Rev Time 0.00
Received By jgomez Date 2012-10-23 Time 14:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-10-03 Cont ID  
Sent By jgomez Date 2012-10-03 Time 16:58 Rev Time 0.00
Received By jgomez Date 2012-10-03 Time 16:08 Sent To  
Notes
2012-10-03 16:59:41NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
  
 1- RETURN AIR CAN'T BE LOCATED IN KITCHEN. REVISE AS
 REQUIRED. M1602.2. OF 2010 FBC-RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-10-23 Cont ID  
Sent By jgomez Date 2012-10-23 Time 14:37 Rev Time 0.00
Received By jgomez Date 2012-10-23 Time 14:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-10-04 Cont ID  
Sent By jgomez Date 2012-10-03 Time 16:27 Rev Time 0.00
Received By jgomez Date 2012-10-03 Time 16:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2012-10-18 Cont ID  
Sent By mdekle Date 2012-10-18 Time   Rev Time 0.00
Received By mdekle Date 2012-10-18 Time   Sent To M
Notes
2012-10-18 09:14:24GAVE TO J.G. - MD

Review Stop Z ZONING
Rev No 1 Status F Date 2012-10-02 Cont ID  
Sent By mdekle Date 2012-10-02 Time   Rev Time  
Received By mdekle Date 2012-10-02 Time   Sent To  
Notes
2012-10-02 08:37:59PLANNING & ZONING: **** FAILED ****
  
 PLEASE RESPOND TO COMMENTS IN WRITING.
  
  
 I. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO SECTION
 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 II. PURSUANT TO SECTION 94-482THE MAXIMUM WIDTH FOR A
 CIRCULAR DRIVEWAY IS TEN (10) FEET. THERE ARE NO
 DIMENSIONS ON THE PROPOSED CIRCULAR DRIVEWAY. (PLEASE
 BE ADVISED, A DRIVEWAY CONNECTION PERMIT FROM THE
 CITY'S ENGINEERING DEPARTMENT IS REQUIRED.)
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME AND/OR
 CONSULT THE CITY?S ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLINE @WWW.MUNICODE.COM.
  
 MURRIAH DEKLE, MPA
 PLANNER
 PLANNING & ZONING DIVISION
 TEL: (561) 822-1442
 EMAIL: [email protected]
  
  
  
  
  
  